PS393

Service Bulletin Details

Public Details for: PS393

Pitstop: gmi fault on aerovironment dc fast charger (level 3) - when encountering customer complaints of a ground monitor interrupt (gmi) fault occurring only when attempting to fast charge on an aerovironment (av) level 3 charger, first v


- 2016 - 2015 -

Models from 2016
2016 KIA SOUL EV
Models from 2015
2015 KIA SOUL EV
SUBJECT:
GROUP
Electrical
MODEL
2015MY
Soul EV (PS EV)
NUMBER
PS393
DATE
April 2015
SOUL EV (PS EV) – GMI FAULT ON
AEROVIRONMENT™ DC FAST CHARGER (LEVEL 3)
When encountering customer complaints of a Ground Monitor Interrupt (GMI) fault occurring
ONLY when attempting to fast charge on an AeroVironment (AV) Level 3 charger, first verify
the vehicle will successfully charge on a non-AeroVironment Level 3 Charger (ABB, Signet,
etc.). If the GMI fault ONLY occurs when charging on the AeroVironment Level 3 charger, the
Battery Management System (BMS) unit may require replacement. Contact Techline to receive
additional diagnostic guidance to resolve this concern.
Page 1 of 1


© dot.report 2024

Use of this information constitutes acceptance for use in an AS IS condition. There are NO warranties, implied or otherwise, with regard to this information or its use. Any use of this information is at the user's risk. It is the responsibility of user to evaluate the accuracy, completeness or usefulness of any information, opinion, advice or other content. EACH USER WILL BE SOLELY RESPONSIBLE FOR ANY consequences of his or her direct or indirect use of this web site. ALL WARRANTIES OF ANY KIND ARE EXPRESSLY DISCLAIMED. This site will NOT BE LIABLE FOR ANY DIRECT, INDIRECT or any other kind of loss.