SSM72206

Service Bulletin Details

Public Details for: SSM72206

"issue only applicable to software versions 30.3 (gen 3) fk72-14c104-af and 29.3 (gen 2) dpla-14c104-ag when checking for fault codes logged in the kvm (keyless vehicle module) also known as the rfa (remote function actuator) f000- 63/u


- 2016 - 2015 - 2014 - 2013 - 2012 - 2011 - 2010 - 2009 -

Models from 2009
2009 JAGUAR XF
Reference
SSM72206
Models
F-TYPE / X152
XE / X760
XF / X250
XF / X260
XJ / X351
Title
Fault code F000-63/U3000-63 logged in the KVM(Keyless vehicle module)
Category
Electrical
Last modified
18-Sep-2015 00:00:00
Symptom
203000 Basic Electrical
Content
Issue
Only applicable to software versions 30.3 (GEN 3) FK72-14C104-AF and 29.3 (GEN 2)
DPLA-14C104-AG
When checking for fault codes logged in the KVM (keyless vehicle module) also known as the RFA (remote function actuator) F00063/U3000-63, Control Module - Circuit/ Component Protection Time-Out is logged.
Cause
This DTC is set when the KVM has gone through a “self reset”
Action
This DTC will not have any effect on functionality. The module must not be replaced .Please carryout a DTC clear. There is a possibility that
it will keep appearing
This issue will be resolved with a later release of software.


© dot.report 2024

Use of this information constitutes acceptance for use in an AS IS condition. There are NO warranties, implied or otherwise, with regard to this information or its use. Any use of this information is at the user's risk. It is the responsibility of user to evaluate the accuracy, completeness or usefulness of any information, opinion, advice or other content. EACH USER WILL BE SOLELY RESPONSIBLE FOR ANY consequences of his or her direct or indirect use of this web site. ALL WARRANTIES OF ANY KIND ARE EXPRESSLY DISCLAIMED. This site will NOT BE LIABLE FOR ANY DIRECT, INDIRECT or any other kind of loss.