SSM72206
Service Bulletin Details
Public Details for: SSM72206
"issue only applicable to software versions 30.3 (gen 3) fk72-14c104-af and 29.3 (gen 2) dpla-14c104-ag when checking for fault codes logged in the kvm (keyless vehicle module) also known as the rfa (remote function actuator) f000- 63/u
- 2016 - 2015 - 2014 - 2013 - 2012 - 2011 - 2010 - 2009 -
Models from 2016
2016 JAGUAR F-TYPE |
2016 JAGUAR XF |
Models from 2015
2015 JAGUAR F-TYPE |
2015 JAGUAR XF |
2015 JAGUAR XJ |
Models from 2014
2014 JAGUAR F-TYPE |
2014 JAGUAR XF |
2014 JAGUAR XJ |
Models from 2013
2013 JAGUAR XF |
2013 JAGUAR XJ |
Models from 2012
2012 JAGUAR XF |
2012 JAGUAR XJ |
Models from 2011
2011 JAGUAR XF |
2011 JAGUAR XJ |
Models from 2010
2010 JAGUAR XF |
2010 JAGUAR XJ |
Models from 2009
2009 JAGUAR XF |
Reference SSM72206 Models F-TYPE / X152 XE / X760 XF / X250 XF / X260 XJ / X351 Title Fault code F000-63/U3000-63 logged in the KVM(Keyless vehicle module) Category Electrical Last modified 18-Sep-2015 00:00:00 Symptom 203000 Basic Electrical Content Issue Only applicable to software versions 30.3 (GEN 3) FK72-14C104-AF and 29.3 (GEN 2) DPLA-14C104-AG When checking for fault codes logged in the KVM (keyless vehicle module) also known as the RFA (remote function actuator) F00063/U3000-63, Control Module - Circuit/ Component Protection Time-Out is logged. Cause This DTC is set when the KVM has gone through a “self reset” Action This DTC will not have any effect on functionality. The module must not be replaced .Please carryout a DTC clear. There is a possibility that it will keep appearing This issue will be resolved with a later release of software.