"situation: the vehicle battery may be flat or one of the following messages/warning lights may be displayed on the instrument cluster. Faulty generator faulty battery monitoring system (bms) the charge warning indicator is illumi
- 2016 - 2015 - 2014 - 2013 - 2012 - 2011 - 2010 -
Models from 2016
2016 JAGUAR XF |
Models from 2015
2015 JAGUAR F-TYPE |
2015 JAGUAR XF |
2015 JAGUAR XJ |
2015 JAGUAR XK |
Models from 2014
2014 JAGUAR F-TYPE |
2014 JAGUAR XF |
2014 JAGUAR XJ |
2014 JAGUAR XK |
Models from 2013
2013 JAGUAR XF |
2013 JAGUAR XJ |
2013 JAGUAR XK |
Models from 2012
2012 JAGUAR XF |
2012 JAGUAR XJ |
2012 JAGUAR XK |
Models from 2011
2011 JAGUAR XF |
2011 JAGUAR XJ |
2011 JAGUAR XK |
Models from 2010
2010 JAGUAR XF |
2010 JAGUAR XJ |
2010 JAGUAR XK |
Page 1 of 3 TECHNICAL BULLETIN JTB00446NAS2 23 NOV 2015 © Jaguar Land Rover North America, LLC NOTE: The information in Technical Bulletins is intended for use by trained, professional Technicians with the knowledge, tools, and equipment required to do the job properly and safely. It informs these Technicians of conditions that may occur on some vehicles, or provides information that could assist in proper vehicle service. The procedures should not be performed by 'do-it-yourselfers'. If you are not a Retailer, do not assume that a condition described affects your vehicle. Contact an authorized Jaguar service facility to determine whether this bulletin applies to a specific vehicle. This reissue replaces all previous versions. Please destroy all previous versions. Changes are highlighted in gray SECTION: 414-00 Battery And/Or Charging System Concerns AFFECTED VEHICLE RANGE: F-TYPE (X152) Model Year: 2014 Onwards VIN: K00317 Onwards Manufacturing Plant: Castle Bromwich XE (X760) Model Year: 2017 Onwards VIN: 900000 Onwards Manufacturing Plant: Solihull XF (X260) Model Year: 2016 Onwards VIN: Y00001 Onwards Manufacturing Plant: Castle Bromwich XJ Range (X351) Model Year: 2010 Onwards VIN: V00001 Onwards Manufacturing Plant: Castle Bromwich XF (X250) Model Year: 2010-2015 VIN: R36912-U88785 Manufacturing Plant: Castle Bromwich XK Range (X150) Model Year: 2010-2015 VIN: B32753-B56794 Manufacturing Plant: Castle Bromwich MARKETS: NAS CONDITION SUMMARY: Situation: The vehicle battery may be flat or one of the following messages/warning lights may be displayed on the Instrument Cluster. • Faulty generator http://topix.jaguar.jlrext.com/topix/service/document/598921 12/3/2015 Page 2 of 3 • Faulty Battery Monitoring System (BMS) • The charge warning indicator is illuminated when the engine is running Cause: The power supply is a fully integrated system that requires SDD to diagnose overall functionality robustly to make sure customer satisfaction is met via right first time diagnosis. Action: Should a customer express this concern, follow the Diagnostic Procedure below. PARTS: No Parts Required TOOLS: NOTE: this Active Bulletin will display a functional programming shortcut if accessed within a diagnostic session using SDD. SDD with latest DVD and Calibration File Jaguar Land Rover-approved Midtronics battery power supply WARRANTY: NOTE: Repair procedures are under constant review, and therefore times are subject to change; those quoted here must be taken as guidance only. Always refer to TOPIx to obtain the latest repair time. NOTE: DDW requires the use of causal part numbers. Labor only claims must show the causal part number with a quantity of zero. DESCRIPTION SRO TIME (HOURS) CONDITION CODE CAUSAL PART Battery - Power supply service mode diagnostic 86.98.25 0.3 42 Refer to the Service Information section NOTE: Normal Warranty procedures apply. SERVICE INFORMATION: 1The casual part number will vary depending on the findings of the Diagnostic Procedure. Make sure the relevant causal part number is claimed based on the results. DIAGNOSTIC PROCEDURE: CAUTION: a Jaguar Land Rover-approved Midtronics battery power supply must be connected to the vehicle battery during SDD diagnosis / module programming. CAUTION: ensure all ignition ON / OFF requests are carried out; failure to perform these steps may cause damage to control modules in the vehicle. NOTE: SDD must be loaded with DVD142.06 v.215 or later. 1Connect the Jaguar Land Rover-approved Midtronics battery power supply to the vehicle battery. 2Turn ignition ON (engine not running). http://topix.jaguar.jlrext.com/topix/service/document/598921 12/3/2015 Page 3 of 3 3Connect the Symptom Driven Diagnostics (SDD) system to the vehicle and begin a new session. 4Follow the on-screen prompts, allowing SDD to read the VIN and identify the vehicle and initiating the data collect sequence. 5Select Diagnosis from the Session Type screen. 6Select the Selected Symptoms tab, and then select: • Electrical > Battery > Charging system > Battery monitoring system or • Electrical > Instruments > Warning lamps > Battery and alternator lamp or • Powertrain > Engine system > Starting system > Start-stop system 7Select continue. 8Select the Recommendations tab, and then select Run to perform the Battery - Power supply service mode diagnostic option. 9Follow all of the on screen instructions to complete the application. 10After the application has finished, follow the on-screen instructions for the next steps. 11When all of the tasks are complete, exit the current session. 12Disconnect the SDD and the battery power supply from the vehicle. http://topix.jaguar.jlrext.com/topix/service/document/598921 12/3/2015