BS3080ER1
Service Bulletin Details
Public Details for: BS3080ER1
Cecm could be replace with a mcm module to reduce download time
Models from 2011
2011 NOVA BUS LFS |
Models from 2010
2010 NOVA BUS LFS ARTIC |
Models from 2009
2009 NOVA BUS LFS ARTIC |
sav.1E.2012MA BS3080ER1 service bulletin Reference: Nova Bus Manuals section: 16: 24-Volt Electrical System RS NO: N/A effective IN prod.: L621 (2011AL) Subject: V-BEA module Justification: CECM could be replace with a MCM module to reduce download time Level 1 application deadline: 2016JL31 Claim reference number: wB-3080 DIRECT CHARGES Description Material Client Nova Bus – – – – Replace Master ID and CECM by an MCM with new harness kit. 2 time labour – MATeRIaL qTy Part no reV. 1 N81735 NR 1 N60798 A – – dESCRIPTION Replaces part n° Level 1 MCM to RFO to CSP-X89X communication cable MCM V-BEA module – N37152 Level 2 – – – Materials will be available within 42 days. To order, please contact Prevost Parts by phone at 1‑800‑771‑6682, by fax at 1‑888‑668‑2555 or by email at [email protected]. Specify document number, quantity of parts required and shipping address. To obtain the software revision required, contact your after-sales representative disposal of parts removed parts are: discarded * reTAINed Yes – * Dispose of the unused parts and the defective parts in accordance with local environmental standards in effect. revision history rev. Date NR 2014MR14 Initial release Luc Carignan R1 2015JN29 Cable N64009 removed. Cables N60809, N64010 and N64011 replaced by cable N81735. Procedure modified to reflect these cable replacements Luc Carignan Approved by: change description Eric CHAREST Digitally signed by Eric CHAREST DN: cn=Eric CHAREST, o=VOLVO NOVA BUS, ou, [email protected], c=CA Date: 2015.06.26 17:01:39 -04'00' written by page 1 OF 8 service bulletin CLIENT Order Road number from to sav.1E.2012MA BS3080ER1 VIN (2nvy/4RKY...) from to QTy New York City Transit - New York L536 1200 1201 S92U793000490 S92U993000491 2 New York City Transit - New York L545 1202 1289 S92U5A4000001 S92U0A4000098 88 New York City Transit - New York L608 8000 8014 L82U6B4000047 L82U0B4000061 15 New York City Transit - New York L620 8015 8074 L82U2B4000062 L82U7B4000123 60 page 2 OF 8 service bulletin sav.1E.2012MA BS3080ER1 WARNING Follow your internal safety procedures. PROCeDURE This procedure is performed in three steps: 1. Installation of module MCM N60798 and cables 2. Program V-BEA system 3. Modify Cummins accelerator interlock parameter 1. Installation of module MCM N60798 and cableS 1.1. Remove the operator's partition panel. Retain the panel and the hardware. 1.2. Remove the operator's control panel rear access door. 1.3. Open the overhead console door, located above the operator's window. 1.4. With a 5 mm (3/16 in.) nut driver, remove the Master ID anchor nuts from the overhead console panel. Retain the hardware. See Figure 1. 1.5. Install the female connector of the new cable N81735 in the Master ID position on the overhead console panel. Use the retained hardware to attach the connector using a 5 mm (3/16 in.) nut driver. See Figure 1. Master ID connector anchor nuts C B E F POSN 02 POSN 03 POSN 04 POSN 05 POSN 06 J A D POSN 01 H G Figure 1 - Typical Overhead Console Panel page 3 OF 8 service bulletin sav.1E.2012MA BS3080ER1 1.6. Route and connect the portion tag to mcm of cable N81735 to Blue MCM connector operator's control panel. Secure the cable with tie wraps along the routing. See Figure 2. 1.7. Disconnect the blue MCM connector csp-x89h2 from the CECM module. See Figure 2. 1.8. Connect all colored wires (green, white, orange, blue, red and 2 black) of cable N81735 to connector x89h2. See Figure 2 for pin position. 1.9. Replace CECM module with new MCM module N60798, using the same hardware. See Figure 2. 1.10. Connect the drain wire of cable N81735 to the bottom left anchor bolts of MCM module N60798. See Figure 2. 1.11. Close the overhead console door, located above the operator's window. 1.12. Open the left electrical Main Panel door. 1.13. Route through the driver's partition the break out section To GND and To BAT 24V switched of cable N81735 inside the left portion of the main panel. Secure the cable using tie wrap. Connect drain wire to anchor bolt csp-x89h2 in the csp- MCM module N60798 Blue connector CSP-X89H2 Blue connector CSP-X89H2 rear view Belden Cable Orange wire pos. 12 Belden Cable Black wire pos. 8 OR RD GR Belden Cable Green wire pos. 24 Ground 18 gage Black wire pos. 18 BL BK WH Belden Cable White wire pos. 27 Power 18 gage Red wire pos. 19 BK Belden Cable Blue wire pos. 7 Figure 2 - Connection of Cable N81735 to Blue MCM Module Blue Connector page 4 OF 8 service bulletin sav.1E.2012MA BS3080ER1 1.14. Connect the red wire tagged To BAT 24V TB78A-S1. See Figure 3. 1.15. Remove and discard the Master ID. Retain the hardware. 1.16. Connect the black wire tagged To GND of cable N81735 to one of the anchor points used to maintain the Master ID. See Figure 3. 1.17. Disconnect cable rf0-x78c2 from the Master ID module. See Figure 3. 1.18. Close the left electrical main panel doors. switched of cable N81735 to main panel terminal block RF0- Connect red wire to pos. S1 RFO-TB78A Connect black wire to Master ID anchor point Figure 3 - Cable N64011 and N64009 Connection in Main Panel page 5 OF 8 service bulletin 1.19. Install the operator's partition panel using the retained hardware. 1.20. Install the rear access door of the operator's control panel. sav.1E.2012MA BS3080ER1 2. Program V-BEA system 2.1. Download the file FB_LXXX in to the V-BEA system, in accordance with the heading reprogramming the v-bea in section 16: v-bea (Volvo bus Electronic Architecture) of the Nova LFS Maintenance manual. 3. Modify Cummins accelerator interlock parameter 3.1. Open the compartment located at the upper left of the driver's seat. 3.2. Connect one end of the Cummins Inline interface to the DDR plug in the panel located in the compartment and to your laptop computer. See Figure 4. C B E F POSN 02 POSN 03 POSN 04 POSN 05 POSN 06 J A D POSN 01 H G DDR connector Figure 4 - DDR Connector in a Typical Control Panel page 6 OF 8 service bulletin 3.3. Open the Cummins Insite software. 3.4. Select Connect to ECM. See Figure 5. 3.5. Select Features and parameters. See Figure 5. sav.1E.2012MA BS3080ER1 Select Connect to ecm Select Feature and parameters Figure 5 - Cummins Insite Homepage 3.6. Locate and open the SAE J1939 Multiplexing line. See Figure 6. sae j1939 multiplexing line Figure 6 - SAE J1939 Open Menu page 7 OF 8 sav.1E.2012MA BS3080ER1 service bulletin 3.7. Change the Accelerator Interlock Switch parameter from Disable to Enable. See Figure 7. Select enable Figure 7 - 3.8. Select Exit button in order to save the new parameter in ECM. Accept the changes by selecting YES. See Figure 8. Select exit button Select yes to accept the changes Figure 8 - 3.9. Close the Cummins Insite software and disconnect the Inline interface cable from the DDR Connector. 3.10. Close the compartment located at the upper left of the driver's seat. page 8 OF 8