PIP5115

Service Bulletin Details

Public Details for: PIP5115

This preliminary information communication provides information to the technician about vehicles that have diagnostic trouble code P0011 after the camshaft was replaced. Technician should check the part number on the cam that was replaced f


- 2014 - 2013 - 2012 - 2011 - 2010 -

Bulletin No.: PIP5115
Date: Apr-2013
Subject:
SES Lamp P0011 Setting After Camshaft Replacement
Models:
2010-2014 Cadillac Escalade
2010-2014 Chevrolet Camaro
2010-2014 GMC Yukon Denali
With engine RPO 6.2L L94 L99
The following diagnosis might be helpful if the vehicle exhibits the symptom(s) described in this PI.
Condition/Concern
You may encounter a P0011 setting after the replacement of the camshaft.
Recommendation/Instructions
Inspect the camshaft to determine if the correct Part number has been installed. The inspection consists of verifying the last 4 digits on the camshaft (stamped
on the end) match the part number listed on the box.
1.
Shows a good camshaft
2.
Shows the wrong camshaft
Warranty Information
For vehicles repaired under warranty use:
Labor Operation
Description
1
Labor Time
J0850
Camshaft Replacement
Use Published Labor Operation Time
Please follow this diagnostic or repair process thoroughly and complete each step. If the condition exhibited is resolved without completing every step, the
remaining steps do not need to be performed.
GM bulletins are intended for use by professional technicians, NOT a "do-it-yourselfer". They are written to inform these technicians of conditions that may
occur on some vehicles, or to provide information that could assist in the proper service of a vehicle. Properly trained technicians have the equipment, tools,
safety instructions, and know-how to do a job properly and safely. If a condition is described, DO NOT assume that the bulletin applies to your vehicle, or that
your vehicle will have that condition. See your GM dealer for information on whether your vehicle may benefit from the information.
WE SUPPORT VOLUNTARY TECHNICIAN CERTIFICATION
2


© dot.report 2024

Use of this information constitutes acceptance for use in an AS IS condition. There are NO warranties, implied or otherwise, with regard to this information or its use. Any use of this information is at the user's risk. It is the responsibility of user to evaluate the accuracy, completeness or usefulness of any information, opinion, advice or other content. EACH USER WILL BE SOLELY RESPONSIBLE FOR ANY consequences of his or her direct or indirect use of this web site. ALL WARRANTIES OF ANY KIND ARE EXPRESSLY DISCLAIMED. This site will NOT BE LIABLE FOR ANY DIRECT, INDIRECT or any other kind of loss.