Technical Information Bulletin
Gage Cluster Transmission Oil Temperature Is Inaccurate After Cluster Replacement
{7000}
Media Number -TIBU7282-00
Publication Date -16/09/2013
Date Updated -16/09/2013
Caterpillar: Confidential Yellow
i05452554
Gage Cluster Transmission Oil Temperature Is Inaccurate
After Cluster Replacement{7000}
SMCS - 7000
On Highway Truck:
CT660 (S/N: TGA1-UP; TGD1-UP; TEJ1-UP; TRK1-UP; TKL1-UP; TEP1-UP; TJS1UP; TGT1-UP; TSW1-UP; TSY1-UP; TGZ1-UP)
Introduction
The gage cluster software may need flashed after cluster has been replaced.
Problem
The transmission oil temperature gage reads maximum when a new gage cluster is installed.
Solution
The gage cluster should not be replaced when transmission oil temperature reads maximum after new
cluster is installed. The cluster should be flashed to the 1.3 software for NON SCR trucks. SCR trucks
have the correct software installed. There is one cluster tool per service representative. The service
representative will have to be contacted to get the tool. The 1.3 software will make the cluster learn
the transmission type on every key cycle.
https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/siswe...
10/2/2013
Advanced Full Text Search - TIBU7282 - Gage Cluster Transmission Oil Temperature Is ... Page 2 of 2
Copyright 1993 - 2013 Caterpillar Inc.
Wed Oct 2 17:10:26 CDT 2013
All Rights Reserved.
chrismk2
Private Network For SIS Licensees.
https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/siswe...
10/2/2013


© dot.report 2024

Use of this information constitutes acceptance for use in an AS IS condition. There are NO warranties, implied or otherwise, with regard to this information or its use. Any use of this information is at the user's risk. It is the responsibility of user to evaluate the accuracy, completeness or usefulness of any information, opinion, advice or other content. EACH USER WILL BE SOLELY RESPONSIBLE FOR ANY consequences of his or her direct or indirect use of this web site. ALL WARRANTIES OF ANY KIND ARE EXPRESSLY DISCLAIMED. This site will NOT BE LIABLE FOR ANY DIRECT, INDIRECT or any other kind of loss.