TSB170047-011820
Service Bulletin Details
Public Details for: TSB170047-011820
This technical service bulletin describes the verification and resolution of the alignment arrows on aftertreatment diesel particulate filter (dpf) and aftertreatment decomposition tube are intentionally misaligned by approximately 10 degre
- 9999 -
Models from 9999
9999 CUMMINS B6.7 |
9999 CUMMINS L9 |
9999 CUMMINS X15 |
Aftertreatment System Alignment Arrows Misaligned on Firetruck Applications Page 1 of 3 Technical Service Bulletin Technical Service Bulletin: Released Date: 18-Jan-2018 TSB170047 Aftertreatment System Alignment Arrows Misaligned on Firetruck Applications Aftertreatment System Alignment Arrows Misaligned on Firetruck Applications Warranty Statement The information in this document has no effect on present warranty coverage or repair practices, nor does it authorize TRP or Campaign actions. Contents Products Affected: • • • • B6.7 CM2350 B121B L9 CM2350 L116B X15 CM2350 X114B X15 CM2350 X116B OEMs Affected: • Pierce • Vanhool Issue This document describes required misalignment of aftertreatment alignment arrows only on firetruck applications. Verification Alignment arrows on aftertreatment diesel particulate filter (DPF) and aftertreatment decomposition tube are intentionally misaligned by approximately 10 degrees. See Figure 1 below. https://qsol.cummins.com/qs3/pubsys2/xml/en/tsb/2017/tsb170047.html 1/22/2018 Aftertreatment System Alignment Arrows Misaligned on Firetruck Applications Page 2 of 3 Figure 1, Alignment Arrows. Resolution CAUTION If aftertreatment DPF and aftertreatment decomposition tube alignment arrows are in alignment, differential pressure sensor tube connected to aftertreatment decomposition tube will not fit properly and can become kinked and/or bent. • Misalignment of aftertreatment DPF and aftertreatment decomposition tube is required to allow for adequate aftertreatment system clearance in this application. • Prior to loosening or removal of aftertreatment v-band clamp, aftertreatment DPF, or aftertreatment decomposition tube; an orientation reference line must be drawn across aftertreatment DPF, v-band clamp, and decomposition tube to aid in assembly. • Use orientation reference lines added prior to loosening or removal to assist in correct differential pressure sensor tube alignment during assembly. Document History Date Details https://qsol.cummins.com/qs3/pubsys2/xml/en/tsb/2017/tsb170047.html 1/22/2018 Aftertreatment System Alignment Arrows Misaligned on Firetruck Applications Date Page 3 of 3 Details 2017-4-7 Module Created 2018-1-18 Added affected OEMs Last Modified: 18-Jan-2018 https://qsol.cummins.com/qs3/pubsys2/xml/en/tsb/2017/tsb170047.html 1/22/2018