Some 2012 - 2013 model year camry vehicles may exhibit a condition where the hvac system intermittently blows warm air from the vents with the a/c on. Diagnostic trouble code (dtc) B1479 (flow sensor circuit) may be stored in the a/c system
Models from 2013
2013 TOYOTA CAMRY |
Models from 2012
2012 TOYOTA CAMRY |
July 12, 2013 T-SB-0084-13 Warm Air from HVAC Vents with A/C ON - DTC B1479 Service Category Vehicle Interior Section Heating/Air Conditioning Market USA Applicability YEAR(S) MODEL(S) 2012 – 2013 Camry ADDITIONAL INFORMATION Introduction Some 2012 – 2013 model year Camry vehicles may exhibit a condition where the HVAC system intermittently blows warm air from the vents with the A/C ON. Diagnostic Trouble Code (DTC) B1479 (Flow Sensor Circuit) may be stored in the A/C system as either a current or history DTC. A malfunctioning A/C compressor flow sensor may cause this condition. Follow the procedure in this bulletin to determine if it is applicable to repair the vehicle. Production Change Information This bulletin applies to vehicles produced BEFORE the Production Change Effective VINs shown below. PLANT MODEL LINE 1 TMMK Camry 2 – SIA DRIVETRAIN PRODUCTION CHANGE EFFECTIVE VIN 2GR-FE 4T1BK1FK#DU020397 2AR-FE 4T1BF1FK#DU209020 2GR-FE 4T1BK1FK#DU525653 2AR-FE 4T1BF1FK#DU641325 2AR-FE 4T4BF1FK#DR278036 Parts Information PART NUMBER PART NAME QTY 88320-06190 Compressor Assy, Cooler 1 88310-0R014 Compressor Assy, w/Pulley 1 PREVIOUS NEW 88320-33240 88310-0R013 © 2013 Toyota Motor Sales, USA Page 1 of 4 July 12, 2013 T-SB-0084-13 Page 2 of 4 Warm Air from HVAC Vents with A/C ON - DTC B1479 Warranty Information OP CODE DESCRIPTION ENGINE TIME OFP AC1205 R & R Compressor with Magnetic Clutch Assembly 2AR-FE 3.0 88310-0R013 2GR-FE 3.4 88320-33240 T1 T2 7A 54 APPLICABLE WARRANTY • This repair is covered under the Toyota Basic Warranty. This warranty is in effect for 36 months or 36,000 miles, whichever occurs first, from the vehicle’s in-service date. • Warranty application is limited to occurrence of the specified condition described in this bulletin. Required Tools & Equipment REQUIRED EQUIPMENT SUPPLIER Techstream 2.0* TIS Techstream PART NUMBER QTY TS2UNIT 1 TSPKG1 ADE Techstream Lite TSLITEDLR01 * Essential SST. NOTE • Only ONE of the Techstream units listed above is required. • Software version 8.10.021 or later is required. • Additional Techstream units may be ordered by calling Approved Dealer Equipment (ADE) at 1-800-368-6787. REQUIRED EQUIPMENT R-134a Refrigerant Recovery/Recycling Machine SUPPLIER PART NUMBER ADE – NOTE Additional refrigerant service equipment may be ordered by calling Approved Dealer Equipment (ADE) at 1-800-368-6787. © 2013 Toyota Motor Sales, USA July 12, 2013 T-SB-0084-13 Page 3 of 4 Warm Air from HVAC Vents with A/C ON - DTC B1479 Repair Procedure 1. Using TIS Techstream, check for Diagnostic Trouble Codes (DTCs) in the A/C system. • If DTC B1479 is stored as a current or history DTC, go to step 2. • If DTC B1479 is NOT stored as current or history, this bulletin does NOT apply. Refer to the Problem Symptoms Table of the Repair Manual. Refer to the Technical Information System (TIS), applicable model and model year Repair Manual: • 2012 Camry: Vehicle Interior – Heating/Air Conditioning: “Heating/Air Conditioning: Air Conditioning System (for Automatic Air Conditioning System) / (for Manual Air Conditioning System): Problem Symptoms Table” • 2013 Camry: Vehicle Interior – Heating/Air Conditioning: “Heating/Air Conditioning: Air Conditioning System (for Automatic Air Conditioning System) / (for Manual Air Conditioning System): Problem Symptoms Table” 2. Using Techstream, inspect the flow sensor. A. Turn Key ON Engine ON. B. Connect Techstream to the DLC3. C. Enter the following menus: Body Electrical / Air Conditioner / Data List D. Check the “Flow Sensor” voltage. (1) If the A/C is OFF and the voltage reading is LESS than 3.7 V, continue to step 3. (2) If the A/C is ON and the voltage reading is MORE than 3.7 V, evacuate the A/C system and verify refrigerant charge level. (3) Verify the AC system is fully charged. If the system is under charged, recharge and see if the B1479 DTC resets. (4) If the system is fully charged, continue to step 3. © 2013 Toyota Motor Sales, USA July 12, 2013 T-SB-0084-13 Page 4 of 4 Warm Air from HVAC Vents with A/C ON - DTC B1479 Repair Procedure (Continued) 3. Check the harness between the A/C compressor flow sensor and the A/C amplifier. A. Disconnect the I77 air conditioning amplifier assembly connector. B. Disconnect the E75 cooler compressor assembly (A/C flow sensor) connector. C. Measure the resistance according to the value(s) in the table below. TESTER CONNECTION CONDITION SPECIFIED CONDITION I77-7 (FLOQ) - E75-3 (QUFL) Below 1 Ω I77-13 (SG-2) - E75-2 (SGFL) I77-30 (S5-1) - E75-1 (S5FL) I77-7 (FLOQ) - Body Ground Always I77-13 (SG-2) - Body Ground 10 kΩ or higher I77-30 (S5-1) - Body Ground (1) If any of the harness resistance tests fail, this bulletin does NOT apply. Repair or replace the harness and go to step 5. (2) If all tests are within specifications, proceed to step 4. 4. Remove and replace the A/C compressor. Refer to TIS, applicable model and model year Repair Manual: • 2012 Camry: Vehicle Interior – Heating/Air Conditioning – “Heating/Air Conditioning: Compressor (for 2AR-FE): Removal / Installation” • 2012 Camry: Vehicle Interior – Heating/Air Conditioning – “Heating/Air Conditioning: Compressor (for 2GR-FE): Removal / Installation” • 2013 Camry: Vehicle Interior – Heating/Air Conditioning – “Heating/Air Conditioning: Compressor (for 2AR-FE): Removal / Installation” • 2013 Camry: Vehicle Interior – Heating/Air Conditioning – “Heating/Air Conditioning: Compressor (for 2GR-FE): Removal / Installation” 5. Clear all DTCs and confirm the A/C system is operating correctly. © 2013 Toyota Motor Sales, USA