LI72.40-P-065509

Service Bulletin Details

Public Details for: LI72.40-P-065509

Window lifter reverses direction


- 2017 - 2016 -

Window lifter reverses direction
Topic number
LI72.40-P-065509
Version
1
Design group
72.40 Door control
Date
01-09-2017
Validity
MODEL 205/253
Reason for change
Reason for block
Complaint:
Window lifter reverses direction on reaching upper closing end position.
In Xentry Diagnostics (XD) the power window system is shown as "normalized".
Path in XD:
XD => Control units view => DCU-xx => Actual values => Power windows => Normalization of power window
Cause:
Software parameter in door control unit (DCU-xx).
Remedy:
Remedy in preparation.
In the event of complaints, and until such time as the repair software becomes available, the power window system
must be denormalized using XD and then renormalized again.
Path in XD (denormalization/normalization):
- XD => Control units view => DCU-xx => Actuations => Power windows => Denormalization of power window
- XD => Control units view => DCU-xx => Adaptations => Teach-in processes => Normalization of power window
The repair software is expected to be available in 03/2017.
Note: Parts replacement will not remedy this complaint!
Symptoms
Body / Glazing / Window lifting mechanism/window operation / Remains stationary
Body / Glazing / Window lifting mechanism/window operation / Does not run up
Body / Glazing / Window lifting mechanism/window operation / Stiff/sluggish
Body / Glazing / Window lifting mechanism/window operation / Opens by itself
01-09-2017 4:57 PM
© Copyright Daimler AG
BRABENS
Page 1/2
Control unit/fault code
Control unit
Fault code
Fault text
N69/1 - Left front door (DCULF) (DMFL222) (C (205))
-
-
N69/2 - Right front door (DCU- RF) (DMFR222) (C (205))
-
N69/3 - Left rear door (DCULR) (DMRL222) (C (205))
-
-
N69/4 - Right rear door (DCU- RR) (DMRR222) (C (205))
-
Operation numbers/damage codes
Op. no.
Operation text
Time
Damage
code
Note
72220 GR
72230 GR
73A30 GR
73N30 GR
54-0650
54-1011
54-0992
01-09-2017 4:57 PM
© Copyright Daimler AG
BRABENS
Page 2/2


© dot.report 2024

Use of this information constitutes acceptance for use in an AS IS condition. There are NO warranties, implied or otherwise, with regard to this information or its use. Any use of this information is at the user's risk. It is the responsibility of user to evaluate the accuracy, completeness or usefulness of any information, opinion, advice or other content. EACH USER WILL BE SOLELY RESPONSIBLE FOR ANY consequences of his or her direct or indirect use of this web site. ALL WARRANTIES OF ANY KIND ARE EXPRESSLY DISCLAIMED. This site will NOT BE LIABLE FOR ANY DIRECT, INDIRECT or any other kind of loss.