LI83.70-N-059145

Service Bulletin Details

Public Details for: LI83.70-N-059145

Runtime of the auxiliary heater is too short (heating duration changed).


- 9999 -

Runtime of the auxiliary heater is too short (heating duration changed).
Topic number
LI83.70-N-059145
Version
1
Design group
83.70 Stationary heater, auxiliary heater
Date
06-09-2014
Validity
Model 906 with CODE H12 (Auxiliary water heater)
Model 906 with CODE HZ5 (Auxiliary water heater with timer 10kW)
Reason for change
Reason for block
Complaint:
Runtime of the auxiliary heater is too short (heating duration changed)
Cause:
Changed heating duration of auxiliary heater with introduction of STH control unit (N33/3) A 906 900 78 01 and the
new auxiliary heater A 906 830 59 00.
Remedy:
Note:
Model 906.### #E as of 068531, model 906.### #N as of 527179 and model 906.### #S as of 708568 are fitted with
the control unit A 906 900 78 01 and the new auxiliary heater A 906 830 59 00 as standard. The modification for the
auxiliary heater is carried out only at the request of the customer. For this reason, the costs must be billed to the customer.
1.
Check control unit version with XENTRY DAS.
Note: No further action is required for STH control unit (N33/3) A 906 900 11 00 or model 906.### # up to E068530,
N527178, S708567.
For STH control unit (N33/3) A 906 900 78 01 or model 906.### # as of E068531, N527179, S708568, continue with
step 2.
---------------------------------------------------------------------------------------------------------------------------------------------------------------------2.
Remove auxiliary heater (see AR83.70-D-5945B).
---------------------------------------------------------------------------------------------------------------------------------------------------------------------3.
Remove STH control unit (N33/3) (see AR83.70-D-5937H).
Note: Do not remove the protective foil.
---------------------------------------------------------------------------------------------------------------------------------------------------------------------4.
Install STH control unit (N33/3) A 906 900 11 00 (see AR83.70-D-5937H).
Note: It is not necessary to attach a new protective foil.
---------------------------------------------------------------------------------------------------------------------------------------------------------------------06-09-2014 9:08 PM
© Copyright Daimler AG
RGHAZIZ
Page 1/3
5.
Install auxiliary heater (see AR83.70-D-5945B).
No restriction of heating duration by control unit
With the modification the heating duration is not limited by the control unit. The heating duration of the auxiliary heater
is therefore no longer dependent on the outside temperature or the charge level of the starter battery. The total heating duration is now determined solely by the operating period programmed by the user (max. 60 minutes per ON cycle).
Therefore, in the case of vehicles as of vehicle identification number 906.### #E068531, N527179, S708568, the section "Heating duration" in the "Climate control" chapter of the operator's manual is no longer applicable after the modification.
Note:
Please remind your customers that when the auxiliary heater is operated for long periods, the engine should be running in order to protect the starter battery. Otherwise it cannot be guaranteed that the engine will start (due to the low
charge level in the starter battery).
Changing the operating period manually
The modification also allows the operating period to be changed manually using the remote control (special equipment). Further details on this can be found in the vehicle operator's manual in the "Climate control" chapter.
Symptoms
Body / Air conditioning / Stationary heater/auxiliary heater / Insufficient heat output
Parts
Part number
ES1 ES2 Designation
A 906 900 11 00
Quantity Note
Control unit
1
EPC Other
make
part
In the EPC this part is restricted to certain vehicle ident
numbers and production dates. However, the component
can be installed without restriction.
X
Work units
Op. no.
Operation text
83-5332
83-5931
Damage
code
Note
REMOVE/INSTALL WATER HEATER
OF AUXILIARY HEATER
83501 53
Stationary heater/heater booster insufficient effect/power
REPLACE CONTROL UNIT ON WATER HEATER
83501 53
Stationary heater/heater booster insufficient
effect/power
06-09-2014 9:08 PM
© Copyright Daimler AG
Time
RGHAZIZ
Page 2/3
Validity
Vehicle
Engine
Transmission
Sprinter III
*
*
06-09-2014 9:08 PM
© Copyright Daimler AG
RGHAZIZ
Page 3/3


© dot.report 2024

Use of this information constitutes acceptance for use in an AS IS condition. There are NO warranties, implied or otherwise, with regard to this information or its use. Any use of this information is at the user's risk. It is the responsibility of user to evaluate the accuracy, completeness or usefulness of any information, opinion, advice or other content. EACH USER WILL BE SOLELY RESPONSIBLE FOR ANY consequences of his or her direct or indirect use of this web site. ALL WARRANTIES OF ANY KIND ARE EXPRESSLY DISCLAIMED. This site will NOT BE LIABLE FOR ANY DIRECT, INDIRECT or any other kind of loss.