24-003-15 REV-A

Service Bulletin Details

Public Details for: 24-003-15 REV-A

Air conditioning inoperative this bulletin involves reprogramming the heating ventilation air conditioning (hvac) module with the latest available software. A small number of customers may experience the loss of air conditioning operatio


- 2016 - 2015 -

Models from 2016
2016 FIAT 500
Models from 2015
2015 JEEP RENEGADE
NUMBER:
GROUP:
DATE:
24-003-15 REV. A
Heating & Air
Conditioning
August 29, 2015
This bulletin is supplied as technical information only and is not an authorization for repair. No part of this publication may be reproduced, stored in a retrieval system,
or transmitted, in any form or by any means, electronic, mechanical, photocopying, or otherwise, without written permission of FCA US LLC.
THIS BULLETIN SUPERSEDES SERVICE BULLETIN 24-003-15, DATED JULY 31,
2015, WHICH SHOULD BE REMOVED FROM YOUR FILES. ALL REVISIONS ARE
HIGHLIGHTED WITH **ASTERISKS** AND INCLUDE UPDATED MODEL LIST AND
LABOR OPERATION.
HELP USING THE wiTECH DIAGNOSTIC APPLICATION FOR FLASHING A ECU IS
AVAILABLE BY SELECTING “HELP” THEN “HELP CONTENTS” AT THE TOP OF
THE wiTECH DIAGNOSTIC APPLICATION WINDOW.
THE wiTECH SOFTWARE IS REQUIRED TO BE AT THE LATEST RELEASE BEFORE
PERFORMING THIS PROCEDURE.
SUBJECT:
Air Conditioning Inoperative
OVERVIEW:
This bulletin involves reprogramming the Heating Ventilation Air Conditioning (HVAC)
module with the latest available software.
MODELS:
**2016**
**(FB)**
**Fiat 500X**
**2015**
(BU)
Jeep Renegade
NOTE: **This bulletin applies to FB vehicles built on or before June 15, 2015 (MDH
0623XX).**
NOTE: **This bulletin applies to BU vehicles built on or before June 23, 2015 (MDH
0623XX).**
SYMPTOM/CONDITION:
A small number of customers may experience the loss of air conditioning operation.
24-003-15 REV. A
-2-
DIAGNOSIS:
Using a Scan Tool (wiTECH) with the appropriate Diagnostic Procedures available in
TechCONNECT, verify all systems are functioning as designed. If DTCs or symptom
conditions, are present other than the symptom condition listed above, record the issues
on the repair order and repair as necessary before proceeding further with this bulletin.
If the customer describes the symptom/condition listed above, perform the Repair
Procedure.
REPAIR PROCEDURE:
NOTE: Install a battery charger to ensure battery voltage does not drop below 13.2
volts. Do not allow the charging voltage to climb above 13.5 volts during the
flash process.
NOTE: If this flash process is interrupted/aborted, the flash should be restarted.
1. Reprogram the HVAC with the latest available software. Detailed instructions for
flashing control modules using the wiTECH Diagnostic Application are available by
selecting the “HELP” tab on the upper portion of the wiTECH window, then “HELP
CONTENTS.” This will open the Welcome to wiTECH Help screen where help topics
can be selected.
2. Using wiTECH, restore configuration and align proxi. This routine is available under
the 'Diagnostic Procedures' tab found on the home, 'Vehicle View', page of wiTECH.
3. Clear all DTCs that may have been set in any module due to reprogramming. The
wiTECH application will automatically present all DTCs after the flash and allow them
to be cleared.
POLICY:
Reimbursable within the provisions of the warranty.
TIME ALLOWANCE:
Labor Operation
No:
18-50-10-93
Description
Module, Heating Ventilation
Air Conditioning (HVAC) Reprogram (0 - Introduction)
Skill Category
Amount
07 - A/C and Heating 0.2 Hrs
NOTE: The expected completion time for the flash download portion of this
procedure is approximately 2 minutes. Actual flash download times may be
affected by vehicle connection and network capabilities.
-3-
24-003-15 REV. A
FAILURE CODE:
The dealer must choose which failure code to use. If the customer came in with an
issue and the dealer found updated software to correct that issue, use failure code
CC, for all other use failure code RF.
•
•
If the customer’s concern matches the SYMPTOM/CONDITION identified in the
Service Bulletin, than failure code CC is to be used.
If an available flash is completed while addressing a different customer concern,
failure code RF is to be used.
CC
Customer Concern
RF
Routine Flash


© dot.report 2024

Use of this information constitutes acceptance for use in an AS IS condition. There are NO warranties, implied or otherwise, with regard to this information or its use. Any use of this information is at the user's risk. It is the responsibility of user to evaluate the accuracy, completeness or usefulness of any information, opinion, advice or other content. EACH USER WILL BE SOLELY RESPONSIBLE FOR ANY consequences of his or her direct or indirect use of this web site. ALL WARRANTIES OF ANY KIND ARE EXPRESSLY DISCLAIMED. This site will NOT BE LIABLE FOR ANY DIRECT, INDIRECT or any other kind of loss.