651914

Service Bulletin Details

Public Details for: 651914

Dwa siren malfunction. When the anti-theft alarm (dwa) is triggered, the horn comes on instead of the alarm siren. Dwa internal monitoring is too sensitive.


- 2015 - 2014 - 2013 - 2012 -

Page 1 of 2
SI B65 19 14
Audio, Navigation, Monitors, Alarms, SRS
October 2014
Technical Service
SUBJECT
DWA Siren Malfunction
MODEL
F12 (6 Series Convertible)
F33 (4 Series Convertible)
Produced to July 23, 2014
With option 0302 (Alarm system)
SITUATION
When the anti-theft alarm (DWA) is triggered, the horn comes on instead of the alarm siren.
CAUSE
DWA internal monitoring is too sensitive.
CORRECTION
Program the vehicle with ISTA/P 3.53.1 or higher.
PROCEDURE
1. Perform diagnosis using the latest version of ISTA. Only if applicable, diagnose any relevant faults stored in
the DWA alarm system by completing the test plans.
2. Program the vehicle with ISTA/P 3.53.1 or higher.
NOTE: The new integration levels after programming with ISTA/P 3.53.0 are displayed below:
F12
F010-14-07-500
F33
F020-14-07-500
If the I-level is higher and the problem still exists, create a PuMA Info Only case.
Note that ISTA/P will automatically reprogram and code all programmable control modules that do not have the
latest software. For information on programming and coding with ISTA/P, refer to CenterNet / Aftersales Portal /
Service / Workshop Technology / Vehicle Programming.
Always connect a BMW approved battery charger/power supply (SI B04 23 10).
WARRANTY INFORMATION
Covered under the terms of the BMW New Vehicle/SAV Limited Warranty or the BMW Certified Pre-Owned
Program.
Defect Code:
65 75 24 15 00
Labor Operation:
Labor Allowance:
00 00 006
Refer to KSD2
Description:
https://www.bmwtis.net/tiscode/cgi-bin/bulletin.aspx?sie_path=/tsb/bulletins/htm_store/16585.1.B65191... 12/24/2014
Page 2 of 2
Performing “vehicle test” (with
vehicle diagnosis system – checking
faults)
And:
61 21 528
Refer to KSD2
Connect an approved battery
charger/power supply (indicated in
KSD2 as “Charging battery”)
Refer to KSD2
Programming/encoding control unit
(s)
And:
61 00 730
Labor operation code 00 00 006 is a main labor operation. If you are using a main labor code for another repair,
use the plus code labor operation 00 00 556 instead.
If a control module or component was working properly and/or had no related faults stored prior to vehicle
programming and it fails to program correctly or requires initialization, this additional work must be claimed with
separate labor operations under the defect code listed above; refer to KSD2.
Repairs to control modules and components with pre-existing conditions are not eligible to be claimed under the
defect code listed in this bulletin.
Other Repairs
If performing ISTA diagnostics and related test plans results in other eligible and covered work, claim this work
with the applicable defect code and labor operations listed in KSD2.
[ Copyright ©2014 BMW of North America, Inc. ]
https://www.bmwtis.net/tiscode/cgi-bin/bulletin.aspx?sie_path=/tsb/bulletins/htm_store/16585.1.B65191... 12/24/2014


© dot.report 2024

Use of this information constitutes acceptance for use in an AS IS condition. There are NO warranties, implied or otherwise, with regard to this information or its use. Any use of this information is at the user's risk. It is the responsibility of user to evaluate the accuracy, completeness or usefulness of any information, opinion, advice or other content. EACH USER WILL BE SOLELY RESPONSIBLE FOR ANY consequences of his or her direct or indirect use of this web site. ALL WARRANTIES OF ANY KIND ARE EXPRESSLY DISCLAIMED. This site will NOT BE LIABLE FOR ANY DIRECT, INDIRECT or any other kind of loss.