B620716

Service Bulletin Details

Public Details for: B620716

Unintentional active eco-pro bonus miles reset. Fluctations of fuel level (causing resistance changes in the level sensor) while vehicle is stationary, are interpreted as refueling. This causes active eco pro mode bonus range to reset. Err


- 2017 - 2016 - 2015 - 2014 - 2013 - 2012 - 2011 - 2010 - 2009 -

Page 1 of 2
SI B62 07 16
Instruments
May 2016
Technical Service
Unintentional Active ECO-PRO Bonus Miles Reset
MODEL
F01 (7 Series
Sedan)
F02 (7 Series Sedan
LWB)
F06 (6 Series Gran
Coupe)
F10 (5 Series
Sedan)
F12 (6 Series
Convertible)
F13 (6 Series Coupe)
F07 (5 Series Gran
Turismo)
SITUATION
Fluctations of fuel level (causing resistance changes in the level sensor) while vehicle is stationary,
are interpreted as refueling. This causes active ECO PRO mode bonus range to reset.
CAUSE
Error in instrument cluster application.
CORRECTION
Program and code the vehicle with ISTA/P 3.58.0 (integration level F010-16-03-501) or higher.
PROCEDURE
Run diagnosis with ISTA and work through the corresponding test module.
Program and encode the vehicle with ISTA/P3.58.0 (integration level F010-16-03-501) or higher.
After programming to the afore-mentioned integration level, the ECO-PRO will continue to count
correctly between vehicle refueling.
Note that ISTA/P will automatically reprogram and code all programmable control modules that do
not have the latest software. For information on programming and coding with ISTA/P, refer to
CenterNet / Aftersales Portal / Service / Workshop Technology / Vehicle Programming.
Always connect a BMW approved battery charger / power supply (SI B04 23 10).
WARRANTY INFORMATION
Covered under the terms of the BMW New Vehicle Limited Warranty for Passenger Cars and Light
Trucks or the BMW Certified Pre-Owned Program.
Defect Code:
62 13 10 18 00
Labor Operation:
Labor Allowance:
Description:
00 00 006
Refer to KSD2
Performing “vehicle test” (with
vehicle diagnosis system –
https://www.bmwtis.net/tiscode/cgi-bin/bulletin.aspx?sie_path=/tsb/bulletins/htm_store/327... 6/6/2016
Page 2 of 2
checking faults)
And:
61 21 528
Refer to KSD2
Charging battery
Refer to KSD2
Programming / encoding control
unit(s)
And
61 00 730
If you are using a Main labor code for another repair, use the Plus code labor operation 00 00 556
instead. Refer to KSD2 for the corresponding flat rate unit (FRU) allowances.
Vehicle Programming and Coding
Control module failures that occur during programming:
z
Please claim these consequential repairs under the defect code listed in this bulletin and use
the applicable KSD2 labor operations.
Other Repairs
Control module failures that occur prior to programming:
z
When covered under an applicable limited warranty, claim these repairs using the applicable
defect code and labor operations in KSD2.
[ Copyright ©2016 BMW of North America, Inc. ]
https://www.bmwtis.net/tiscode/cgi-bin/bulletin.aspx?sie_path=/tsb/bulletins/htm_store/327... 6/6/2016


© dot.report 2024

Use of this information constitutes acceptance for use in an AS IS condition. There are NO warranties, implied or otherwise, with regard to this information or its use. Any use of this information is at the user's risk. It is the responsibility of user to evaluate the accuracy, completeness or usefulness of any information, opinion, advice or other content. EACH USER WILL BE SOLELY RESPONSIBLE FOR ANY consequences of his or her direct or indirect use of this web site. ALL WARRANTIES OF ANY KIND ARE EXPRESSLY DISCLAIMED. This site will NOT BE LIABLE FOR ANY DIRECT, INDIRECT or any other kind of loss.