TJ33931.5.0-2019

Service Bulletin Details

Public Details for: TJ33931.5.0-2019

This is a technical journal: spa hybrid irregular electrical distance to empty after software upgrade


- 2019 - 2018 - 2017 - 2016 -

Models from 2016
2016 VOLVO XC90H
VOLVO CAR
SERVICE AND PARTS BUSINESS
Technical Journal
TITLE:
SPA Hybrid Irregular electrical distance to empty after Software upgrade
REF NO:
ISSUING DEPARTMENT:
CAR MARKET:
TJ 33931.5.0
Technical Service
United States and Canada
PARTNER:
ISSUE DATE:
STATUS DATE:
3 US 7510 Volvo Car USA
2019-01-18
2019-01-23
FUNC GROUP:
FUNC DESC:
3113
Battery, high voltage
Page 1 of 2
“Right first time in Time”
Attachment
Vehicle Type
Type
Eng
2XX
2XX
2XX
2XX
BA
BC
BM
BR
Eng
Desc
Sales
Body
Gear
Steer
Model Year
2016-2019
2016-2019
2018-2019
2018-2019
Plant
Chassis range
-
Struc Week
Range
201526-201839
201526-201839
201717-201839
201717-201839
CSC Customer Symptom Codes
Code
YN
YL
YM
FB
Description
High voltage battery/Discharged/poor charge
On board charger/No/reduced/incorrect function/With external cable
On board charger/No/reduced/incorrect function/While driving
Text window and warning symbol/Other problems
VST Operation Number
VST Operation Number
36004-2
36001-2
31116-2
Description
Software control module downloading
Diagnostic trouble codes read / reset / known Diagnostic trouble codes with VIDA
Battery, connection and disconnection
Produced in the USA and available as an electronic document. Hard copy documents are printed in USA on recycled paper containing
a minimum of 50% wastepaper and 10% post-consumer waste.
© 2019 VOLVO CAR USA, LLC
Technical Journal 33931.5.0
DTC Diagnostic Trouble Codes
Control Module
BECM
BECM
BECM
BECM
BECM
BECM
BECM
BECM
Code
P0CA400
U029A00
P0DAF00
P0DB300
P0DB700
P0DBB00
P0DBF00
P0DC300
Fault Type
Intermittent
Intermittent
Intermittent
Intermittent
Intermittent
Intermittent
Intermittent
Intermittent
Rows beginning with * are modified
Note! If using a printed copy of this Technical Journal, first check for the latest online version.
Text
DESCRIPTION:
* VST Operation No updated and SP in service added
If the vehicle displays irregular and low electrical range or State of Charge after Software upgrade and,
in some rare cases, not possible to charge High Voltage battery, follow advice under “Service”
SERVICE:
Disconnect 12 volt battery and wait approx. 20 minutes and connect it again.
If the problem persist then roll back the SW to an earlier status.
If the problem persist then roll back the software to an earlier status using special service software:
XC90/XC60: SP 31483293
* S90L: SP 31472419
VEHICLE REPORT:
Yes, please submit a Vehicle Report if the service solution described in this TJ has no effect. Use
concern area “Vehicle Report” and sub concern area “Support needed”, use function group 3113.
Page 2 of 2
2019-01-23


© dot.report 2024

Use of this information constitutes acceptance for use in an AS IS condition. There are NO warranties, implied or otherwise, with regard to this information or its use. Any use of this information is at the user's risk. It is the responsibility of user to evaluate the accuracy, completeness or usefulness of any information, opinion, advice or other content. EACH USER WILL BE SOLELY RESPONSIBLE FOR ANY consequences of his or her direct or indirect use of this web site. ALL WARRANTIES OF ANY KIND ARE EXPRESSLY DISCLAIMED. This site will NOT BE LIABLE FOR ANY DIRECT, INDIRECT or any other kind of loss.