K23810364

Service Bulletin Details

Public Details for: K23810364

Volvo chassis - volvo active driver assist (vada) communication fault in the driver information display (did) at start up; "missing communication from vada ecu" message in cluster ( mid 140 psid 211 fmi 9 ) - us17+obd16 and newer emissions


- 9999 -

Solution K23810364
Tuesday, March 5, 2019 5:24:51 PM CET
Volvo Models
Volvo Model
VNL , VNR , VNX , VAH , VHD
Emission Standard
Emission Standard
US17+OBD16 , US17+OBD18 , US17+OBD19
** SOLUTION **
Title
Volvo Active Driver Assist (VADA) Communication Fault In The Driver Information
Display (DID) At Start Up; "Missing Communication From VADA ECU" Message In
Cluster ( MID 140 PSID 211 FMI 9 ) - US17+OBD16 and Newer Emissions
Cause
Certain vehicles may exhibit a pop up message for a VADA communication fault. This
message occurs when the Instrument Cluster ( IC ) starts up (within 30 seconds after
ignition starts) and cannot communicate with the VADA ECU. The IC watchdog timer
is set to begin at 20 seconds; however the VADA ECU does not start up until 30
seconds. So the IC timer has been extended to 35 seconds. Psid 211 fmi 9 will also
show when this occurs, Fault will go inactive after message clears.
Solution
For any vehicle displaying the above symtpoms:
Update the Instrument Cluster software.
Internal comments (BO)
(Internal – changes parameter RYC = 35)
Solution visibility
Dealer distribution
Function(s)/component(s) affected
Function affected
MID 140 – IC04 / IC05 , information display control unit
Function Group
Function Group
366 automatic monitoring and control , 381 combined instrument , 384 warning
system , 387 warning/information analysis and display; embedded diagnostic software
Customer effect
Main customer effect
fault code/display
Fault code(s)
NA_MIDs
MID 140 PSID 211 FMI 9
Conditions
Vehicle operating mode
Frequency of occurrence of
problem
on start-up
random
Administration
Author
A241298
Dealer ID
A241298
Last modified by
A084727
Creation date
01-02-2019 20:02
Date of last update
01-03-2019 20:03
Status
Published


© dot.report 2024

Use of this information constitutes acceptance for use in an AS IS condition. There are NO warranties, implied or otherwise, with regard to this information or its use. Any use of this information is at the user's risk. It is the responsibility of user to evaluate the accuracy, completeness or usefulness of any information, opinion, advice or other content. EACH USER WILL BE SOLELY RESPONSIBLE FOR ANY consequences of his or her direct or indirect use of this web site. ALL WARRANTIES OF ANY KIND ARE EXPRESSLY DISCLAIMED. This site will NOT BE LIABLE FOR ANY DIRECT, INDIRECT or any other kind of loss.