Service Bulletin Details
Public Details for: PIC5979B
This preliminary information communication provides information to the technician about vehicles that have the heater-vent-air conditioning system discharge temperature to vary from side to side when the set temperature is set to the same v
- 2019 - 2018 - 2017 - 2016 - 2015 - 2014 - 2013 -
Models from 2019
2019 CADILLAC ATS |
2019 CADILLAC CTS |
Models from 2018
2018 CADILLAC ATS |
2018 CADILLAC CTS |
Models from 2017
2017 CADILLAC ATS |
2017 CADILLAC CTS |
Models from 2016
2016 CADILLAC ATS |
2016 CADILLAC CTS |
Models from 2015
2015 CADILLAC ATS |
2015 CADILLAC CTS |
Models from 2014
2014 CADILLAC ATS |
2014 CADILLAC CTS |
Models from 2013
2013 CADILLAC ATS |
Bulletin No.: PIC5979B Published date: 04/10/2019 Preliminary Information PIC5979B Normal Characteristic - HVAC Temperature Varies from Side to Side Models Brand: Model: Model Years: VIN: from to Engine: Transmissions: Cadillac ATS 2013 - 2019 All All All All Cadillac CTS Sedan (VIN A) 2014 - 2019 All All All All Supersession Statement This PI was superseded to update Model Years. Please discard PIC5979A. The following diagnosis might be helpful if the vehicle exhibits the symptom(s) described in this PI. Condition / Concern A customer may complain about the HVAC system discharge temperature to vary from side to side when the set temperature is set to the same value. Recommendations / Instructions IMPORTANT: Do NOT replace components for this condition. Replacing the duct sensors or temperature motors will not improve this situation. It is normal for a dual zone or tri-zone HVAC system discharge temperature to vary from side to side when the set temperature is set to the same value. The upper duct sensors are placed in the outer parts of the ductwork and do not read the discharge temperature from the center outlets. This can be made worse if the outboard panel outlets are shuto , which will cause the duct sensors not to read properly. In a garage condition, with all of the outlets open after 10 minutes of idling all of the outlets should stabilize within 6 degrees if measured in Celsius, or 12 degrees of each other if measured in Fahrenheit. Starting in the 2015 model year ATS and CTS vehicles, the Upper Duct Temperature Sensors are no longer used in the control of the temperature and use a Virtual Duct Sensor control strategy. Starting in model year 2017 the Upper Duct Temperature Sensors were removed from the ductwork. Customer Information Please communicate to the customer this condition is a normal operating characteristic of their vehicle. It will not impact the designed performance or reliability of the vehicle. Please share this information with the customer, including a copy of this message. Please follow this diagnostic or repair process thoroughly and complete each step. If the condition exhibited is resolved without completing every step, the remaining steps do not need to be performed. Additional SI Keywords blower cold temp warm © 2019 General Motors. All Rights Reserved.