This preliminary information communication provides information to the technician about vehicles that are unable to charge the hybrid battery and the malfunction indicator lamp is illuminated on the instrument panel cluster. Technician may


- 2016 - 2015 - 2014 - 2013 - 2012 - 2011 -

Models from 2016
2016 CADILLAC ELR
Bulletin No.: PIC5921B
Published date: 06/17/2019
Preliminary Information
PIC5921B Unable To Charge Malfunction Indicator Lamp With DTC
P16C1 Or P16C2
Models
Brand:
Model:
VIN:
Model Years:
from
Engine:
to
Transmissions:
Cadillac
ELR
2014 - 2016
All
All
All
All
Chevrolet
Volt
2011 - 2015
All
All
All
All
Chevrolt
Spark EV
2014 - 2015
All
All
All
All
Opel
Ampera
2012 - 2014
All
All
All
All
Supersession Statement
This PI was superseded to update Model Years and Subject. Please discard PIC5921A
The following diagnosis might be helpful if the vehicle exhibits the symptom(s) described in this PI.
Condition / Concern
Some customers may state that they are unable to charge the hybrid battery and the malfunction
Indicator lamp is illuminated onthe IPC.
After inspection, you may notice that the vehicle has a current or history code P16C1 or P16C2 set
in the Battery Charging ControlModule (BCCM).
These codes are usually set as a result of a incomplete BCCM programming event.
Recommendations / Instructions
If you experience this concern, Please update the OBCM with the latest software in TIS-2Web. If
you experience a concern while programmingthe BCCM, please contact T
echline support @ 1-800828-6860
Warranty Information
For vehicles repaired under warranty, use:
Labor Operation
Description
Labor Time
2810285
Battery Charger Control Module
Reprogramming with SPS
Use Published Labor Operation
Time
Please follow this diagnostic or repair process thoroughly and complete each step. If the condition exhibited is
resolved without completing every step, the remaining steps do not need to be performed.
© 2019 General Motors. All Rights Reserved.


© dot.report 2024

Use of this information constitutes acceptance for use in an AS IS condition. There are NO warranties, implied or otherwise, with regard to this information or its use. Any use of this information is at the user's risk. It is the responsibility of user to evaluate the accuracy, completeness or usefulness of any information, opinion, advice or other content. EACH USER WILL BE SOLELY RESPONSIBLE FOR ANY consequences of his or her direct or indirect use of this web site. ALL WARRANTIES OF ANY KIND ARE EXPRESSLY DISCLAIMED. This site will NOT BE LIABLE FOR ANY DIRECT, INDIRECT or any other kind of loss.