K43204335
Service Bulletin Details
Public Details for: K43204335
Electronically controlled air dryer (ecad) diagnostic procedures and information
- 9999 -
Models from 9999
9999 VOLVO VAH |
9999 VOLVO VHD |
9999 VOLVO VN |
9999 VOLVO VNL |
9999 VOLVO VNM |
9999 VOLVO VNR |
9999 VOLVO VT |
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iagnosticGuide Thedryerhasaninletportanoutletportandanunloaderport(whichsendairtothecom Thespinoncartridgeappearsthesame(partnumbernotverifiedbyme) Thepurgevalvelooksthesameasotherdryers(fromtheoutside) Theheaterlooksthesame(fromtheoutside)andhasthesamefunctionandspec. Theoutletcheckvalvelooksthesame(fromtheoutside) ThereisnoturbocutͲoffvalve Purgeunloadandregenerationareallcontrolledbythesolenoidpackonthesideofthedr Roundconnectorwiththefollowingpinlocations: 24 31 Pin4=Ignitionpowerforbothsolenoids Pin3=Groundcontrolsolenoidthatopensthepurgevalveandsendssystemairtoport4 Pin1=Groundcontrolsolenoidthenopenstheregenerationvalveallowingcontrolledout Pin2=NotUsed ResistanceSpecs. Pin1toPin4:11Ͳ16ohms Pin3toPin4:15Ͳ23ohms ECADtroubleshooting: 1) Disconnectthedryerinlet(port1),signal(port4),andoutlet(port2)lines. 2) Disconnectthesolenoidelectricalconnector. 3) Connectshopairwithaclosedvalvetotheinlet. 4) Connectanairgaugeonthesignalline. 5) Connecta1gallonorlargerairtanktotheDryeroutlet. 6) Opentheinletvalvesupplyingshopairtothedryer,andverify: a. Therearenoairleaksfromthedryer b. Theairtankfillswithair c. Thesignalgaugedoesnotmove 7) Closetheinletvalveandsupply12voltstopin4ofthesolenoidandgroundpin3t a. Thedryerpurgesthenstopsleaking b. Thesignalgaugerisestothetankpressure 8) Removethegroundfrompin3thenverify: a. Thesignalgaugefallsto0PSI 9) Groundpin3andpin1ofthesolenoidconnector(12voltsonpin4stillinplace)a a. Thetankdrainsthroughthepurgevalveslowly(desiccantregeneration) 10) Ifthedryerpassestheaboveteststhenthedryerisfunctioningcorrectly.Ifthedry thenrecordresultsandcallOnTracat(866)668Ͳ7221. (&$''LDJQRVWLF*XLGH 0HULWRU:DEFR7HFKQLFDO%XOOHWLQ 0HULWRU:DEFR6\VWHP6DYHU6HULHV6LQJOH&DUWULGJH$LU'U\HUV 6ROXWLRQYLVLELOLW\ 'HDOHUGLVWULEXWLRQ )XQFWLRQ V FRPSRQHQW V DIIHFWHG )XQFWLRQDIIHFWHG $LU'U\HU )XQFWLRQ*URXS )XQFWLRQ*URXS FRPSUHVVRUUHJXODWRUDQWLIUHH]HXQLW &XVWRPHUHIIHFW 0DLQFXVWRPHUHIIHFW QRLVHHIILFLHQF\DEQRUPDOEHKDYLRU 1RLVH KLVVLQJQRLVH )OXLGSUREOHP OHDN )OXLGLPSOLFDWHG $LU $GPLQLVWUDWLRQ $XWKRU $ 'HDOHU,' $ /DVWPRGLILHGE\ $ &UHDWLRQGDWH 'DWHRIODVWXSGDWH 6WDWXV 3XEOLVKHG