Complaint:
In ECO-stop/start mode, the engine may not automatically restart after shutting down at a complete stop. In such instances the engine requires another cycle of the ignition switch.
Cause:
Individualized examination to include further information and analysis is needed. Complaint condition could be due to
a variety of causes.
Remedy:
Generate a PTSS case and escalate it immediately.
Symptoms
Power generation / Engine management / Starter motor / Function / Does not engage
Power generation / Engine management / Engine running / Stalls/goes out
Power generation / Engine management / Engine running / Cuts out intermittently
Power generation / Engine management / Engine start/stop / Does not start
Power generation / Engine management / Engine performance / No/poor output
Power generation / Engine management / Engine start/stop / No automatic engine start
11-19-2019 3:24 PM
© Copyright Mercedes-Benz AG
HENRAND
Page 1/1


© dot.report 2024

Use of this information constitutes acceptance for use in an AS IS condition. There are NO warranties, implied or otherwise, with regard to this information or its use. Any use of this information is at the user's risk. It is the responsibility of user to evaluate the accuracy, completeness or usefulness of any information, opinion, advice or other content. EACH USER WILL BE SOLELY RESPONSIBLE FOR ANY consequences of his or her direct or indirect use of this web site. ALL WARRANTIES OF ANY KIND ARE EXPRESSLY DISCLAIMED. This site will NOT BE LIABLE FOR ANY DIRECT, INDIRECT or any other kind of loss.