Public Details for: TSB190203-120220
This technical service bulletin describes the verification and resolution of engine crank but no start condition due to inducement restart counter being maxed out.
- 9999 -
12/9/2019 Engine Does Not Start Due to Inducement Restart Counter Being Maxed Out Technical Service Bulletin Technical Service Bulletin: TSB190203 Released Date: 02-Dec-2019 Engine Does Not Start Due to Inducement Restart Counter Being Maxed Out Engine Does Not Start Due to Inducement Restart Counter Being Maxed Out Warranty Statement The information in this document has no effect on present warranty coverage or repair practices, nor does it authorize TRP or Campaign actions. Contents Product Affected B4.5 CM2350 B146C B6.7 CM2350 B136C F3.8 CM2350 F128C F3.8 CM2350 F133C L9 CM2350 L120C L9 CM2350 L129C QSB4.5 CM2350 B106 QSB6.7 CM2350 B105 QSB6.7 CM2350 B130 QSF3.8L CM2350 F107 QSF3.8L CM2350 F118 QSF3.8L CM2350 F119 QSG12 CM2350 G110 QSL9 CM2350 L118 QSX15 CM2350 X105 QSX15 CM2350 X106 QSX15 CM2350 X118 X12 CM2350 G110 X12 CM2350 X128C X15 CM2350 X130C X15 CM2350 X131 Issue Symptoms: https://quickserve.cummins.com/qs3/pubsys2/xml/en/tsb/2019/tsb190203.html 1/2 12/9/2019 Engine Does Not Start Due to Inducement Restart Counter Being Maxed Out Engine will crank but not start, while inducement related fault codes are present. Fault Codes: 3714, 3712, 4135, 3931, 6254 or 6255. Verification/Confirmation Verify that this application uses shutdown as final inducement using the recommended Cummins® electronic service tool: Navigate to: Features and parameters, then Final Inducement, then Restart Counter. The Restart Counter should be available if the application is using shutdown as final inducement. Power generation and fixed speed applications typically use shutdown as final inducement. Verify unit has had Fault Code 3714, 3712, 4135, 3931, 6254 and/or 6255 in the past four hours of engine operation. Resolution If a fault code that drives final inducement is set, the restart counter starts at zero and allows limited number of restarts, as determined by the Maximum Restart Limit. The default setting allows four restarts for fifteen minutes. These restarts are meant to allow the service technician to trouble shoot any existing fault codes. The restart counter increments by one after every restart. The engine will not start once the restart limit is exhausted. Use the recommended Cummins® electronic service tool to update the final inducement counter by performing the following actions: Navigate to Features and parameters, Final Inducement, Restart Counter. If the Restart Counter is greater than or equal to Maximum Restart Limit, reduce the Restart Counter by one. Document History Date 2019-11-21 Details Module Created Last Modified: 02-Dec-2019 https://quickserve.cummins.com/qs3/pubsys2/xml/en/tsb/2019/tsb190203.html 2/2