T-TT-0661-21
Service Bulletin Details
Public Details for: T-TT-0661-21
Tt: customer complaint of hvac compressor ?Bang? Type noise upon initial compressor engagement when air conditioning has not been operated for an extended period (~24 hrs. Or longer). The noise is caused by compressor oil collecting in t
Models from 2021
2021 TOYOTA TUNDRA |
Models from 2020
2020 TOYOTA TUNDRA |
Models from 2019
2019 TOYOTA TUNDRA |
Models from 2018
2018 TOYOTA TUNDRA |
Tech Tip T-TT-0661-21 July 21, 2021 Subject Market Bang Noise from HVAC Compressor After Long Periods of No Usage USA Service Category Section Vehicle Interior Heating/Air Conditioning Applicability 2018-2019 Tundra APPLICABLE VEHICLES 2018-2021 Tundra CONDITION Customer complaint of HVAC compressor “Bang” type noise upon initial compressor engagement when air conditioning has not been operated for an extended period (~24 hrs. or longer). The noise is caused by compressor oil collecting in the compressor and upon initial compressor engagement, the compressor must pump the oil out causing the “Bang” noise. Compressor engagements thereafter are normal and less audible as the collected oil has been pumped out. RECOMMENDATIONS This is a normal characteristic and no repairs are recommended. LINK REFERENCES Compressor Engagement Bang Noise Expires on Ver. 2.13 01/01/2021 T 07/21/2022 © 2021, Toyota Motor Sales, USA Page 1 of 1