This technical service bulletin describes the verification and resolution of mis-calibrated turbocharger wastegate pneumatic actuators. This will cause low power condition and fc 2988 or 2989.


- 9999 -

9/3/2021
Fault Code 2988 or 2989 and/or Low Power After ReCon® Wastegate Turbocharger Installation: Caused by Improper Pneumatic Turboch…
Technical Service Bulletin
Technical Service Bulletin: TSB210181
Released Date: 19-Aug-2021
Fault Code 2988 or 2989 and/or Low Power After ReCon® Wastegate Turbocharger
Installation: Caused by Improper Pneumatic Turbocharger Actuator Calibration
Fault Code 2988 or 2989 and/or Low Power After
ReCon® Wastegate Turbocharger Installation:
Caused by Improper Pneumatic Turbocharger
Actuator Calibration
Warranty Statement
The information in this document has no effect on present warranty coverage or repair practices,
nor does it authorize TRP or Campaign actions.
Contents
Product Affected
ISL G CM2180
ISX12 G CM2180 EJ
ISX12N CM2380 X120B
L9N CM2380 L124B
L9N CM2380 L130B
L9N CM2380 L142B
Issue Summary
Some out of the box and early life ReCon® wastegate turbocharger pneumatic actuators built in
ReCon® Memphis Plant (RMP) were not calibrated properly and need to be adjusted in the field
for proper operation.
Symptoms:
Engine has low power after turbocharger installation
Fault Code 2988 or 2989
Root Cause:
Pneumatic turbocharger actuators not calibrated properly for out of the box or early life
ReCon® wastegate turbochargers
https://quickserve.cummins.com/qs3/pubsys2/xml/en/tsb/2021/tsb210181.html
1/5
9/3/2021
Fault Code 2988 or 2989 and/or Low Power After ReCon® Wastegate Turbocharger Installation: Caused by Improper Pneumatic Turboch…
Turbocharger wastegate valve and pneumatic actuator rod not meeting full extension when
tested
Verification
While checking the turbocharger wastegate valve and actuator rod movement they are found
to not meet the proper displacement in some out of the box ReCon® wastegate
turbochargers.
The range of build dates of the ReCon® turbochargers that are suspected to be at risk of not
being calibrated properly are in Table 1.
Figure 1 has an example of how to determine the build date from the RMP turbocharger serial
starting from the left:
4th and 5th digits are the build year
6th and 7th digits are the build day
8th and 9th digits are the build month
Table 1, RMP Suspected Population of Wastegate Turbocharger Pneumatic Actuator Not
Calibrated Properly
Turbo Serial
Number First
(TSNF)
TSNF Build Date
(M04YYDDMM…)
Turbo Serial
Number Last (TSNL)
TSNL Build Date
(M04YYDDMM…)
M04210101001
1 January 2021
M04213103001
31 March 2021
Figure 1, Wastegate Turbocharger Made In RMP on 31 May 2019 (M04YYDDMM…).
https://quickserve.cummins.com/qs3/pubsys2/xml/en/tsb/2021/tsb210181.html
2/5
9/3/2021
Fault Code 2988 or 2989 and/or Low Power After ReCon® Wastegate Turbocharger Installation: Caused by Improper Pneumatic Turboch…
Resolution
Follow the instructions to calibrate the pneumatic turbocharger actuator properly in the ReCon®
wastegate turbocharger:
Preparatory Step
 WARNING 
To reduce the possibility of personal injury, wear goggles and protective clothing.
Tools needed for pneumatic actuator calibration are shown in Figure 2 below:
Dial gauge indicator Part Number 3165168 or equivalent
Air pressure regulator Part Number 3823799 or equivalent
Figure 2, Left: Dial Gauge Indicator. Right: Air Pressure Regulator.
Install
1. Disconnect turbocharger actuator rod from wastegate valve pin by removing the retaining clip
from the control lever.
2. Verify turbocharger wastegate valve can move freely.
3. Loosen control rod jam nut.
4. Pressurize actuator until rod reaches the wastegate valve pin.
5. Adjust the length of the end link screw to meet wastegate valve pin.
6. Connect and secure actuator rod to wastegate valve pin with retaining clip.
7. Set actuator pressure to 0 kPa [ 0 psi ].
https://quickserve.cummins.com/qs3/pubsys2/xml/en/tsb/2021/tsb210181.html
3/5
9/3/2021
Fault Code 2988 or 2989 and/or Low Power After ReCon® Wastegate Turbocharger Installation: Caused by Improper Pneumatic Turboch…
8. Set up dial gauge indicator parallel to actuator rod and zero it at the rod end while verifying the
wastegate valve is fully closed by adjusting the end link screw (Shown in Figure 3, Item 1
below) with the actuator pressure kept at 0 kPa [ 0 psi ] like in Figure 3 below.
9. Pressurize actuator to the corresponding Set Pressure values in Table 2 below.
10. Adjust end link screw until the dial gauge indicator measurement is between the Set
Displacement values in Table 2 below while the actuator is kept at the Set Pressure.
11. Tighten the control rod jam nut to 8.5 N•m [ 75 in-lb ].
12. Set actuator pressure to 0 kPa [ 0 psi ]
13. Pneumatic turbocharger actuator calibration complete and now the mechanism will move
properly.
Figure 3, Dial Gauge Indicator Set Up at Turbocharger Actuator Rod End.
Table 2, Pressure and Displacement Values for Proper Pneumatic Turbocharger Actuator
Calibration
Engine Model
Actuator Set
Pressure
Actuator Rod End
MIN Set
Displacement
Actuator Rod End
MAX Set
Displacement
ISL G
55 kPa [ 8 psi ]
0.50 mm [ 0.020 in ]
1.04 mm [ 0.041 in ]
ISX12 G
100 kPa [ 15 psi ]
0.50 mm [ 0.020 in ]
1.04 mm [ 0.041 in ]
ISX12N
100 kPa [ 15 psi ]
0.50 mm [ 0.020 in ]
1.04 mm [ 0.041 in ]
L9N
55 kPa [ 8 psi ]
0.50 mm [ 0.020 in ]
1.04 mm [ 0.041 in ]
https://quickserve.cummins.com/qs3/pubsys2/xml/en/tsb/2021/tsb210181.html
4/5
9/3/2021
Fault Code 2988 or 2989 and/or Low Power After ReCon® Wastegate Turbocharger Installation: Caused by Improper Pneumatic Turboch…
Document History
Date
2021-8-19
Details
Module Created
Last Modified: 19-Aug-2021
https://quickserve.cummins.com/qs3/pubsys2/xml/en/tsb/2021/tsb210181.html
5/5


© dot.report 2024

Use of this information constitutes acceptance for use in an AS IS condition. There are NO warranties, implied or otherwise, with regard to this information or its use. Any use of this information is at the user's risk. It is the responsibility of user to evaluate the accuracy, completeness or usefulness of any information, opinion, advice or other content. EACH USER WILL BE SOLELY RESPONSIBLE FOR ANY consequences of his or her direct or indirect use of this web site. ALL WARRANTIES OF ANY KIND ARE EXPRESSLY DISCLAIMED. This site will NOT BE LIABLE FOR ANY DIRECT, INDIRECT or any other kind of loss.