TSB220009-011320
Service Bulletin Details
Public Details for: TSB220009-011320
This technical service bulletin describes the verification and resolution of incorrect minimum gap clearance used for reused spark plugs. This condition may cause rough running conditions and multiple fault codes.
- 9999 -
Models from 9999
9999 CUMMINS ISX12 |
9999 CUMMINS ISX12G |
1/31/22, 4:48 PM Revised Minimum Reuse Spark Plug Gap: Inactive Misfire Fault Codes Technical Service Bulletin Technical Service Bulletin: TSB220009 Released Date: 13-Jan-2022 Revised Minimum Reuse Spark Plug Gap: Inactive Misfire Fault Codes Revised Minimum Reuse Spark Plug Gap: Inactive Misfire Fault Codes Warranty Statement The information in this document has no effect on present warranty coverage or repair practices, nor does it authorize TRP or Campaign actions. Contents Product Affected ISX12 G CM2180 EJ ISX12N CM2380 X120B Description of Change The minimum reuse spark plug gap has been revised in Service Manual Procedure 013-016 in Section 13. Reason for Change Symptom: Rough running Fault Code(s): 5895, 5896, 5897, 5898, 5899, 5911, 5911, 5911, 6413, 6425, 6426, 6427, 6428, 6429, 6431 Root Cause: Previous reuse spark plug gap resulted in no trouble found part replacements. Verification Verify unit is running rough or experiencing any of the associated fault codes listed in the Symptom section above. See corresponding Service Manual for spark plug gap specification. Reference Procedure 013-016 in Section 13. Resolution https://quickserve.cummins.com/qs3/pubsys2/xml/en/tsb/2022/tsb220009.html 1/2 1/31/22, 4:48 PM Revised Minimum Reuse Spark Plug Gap: Inactive Misfire Fault Codes Reuse spark plug gap minimum limit has been reduced. Verify the reuse spark plug gap is between the published limit specified. See corresponding Service Manual. Reference Procedure 013-016 in Section 13. Compare the engine control module (ECM) code and revision number in the ECM to the calibration revision listed in the ECM calibration revision history for applicable changes. If a calibration update for this fault code is available, the ECM calibration revision must be that revision or higher. Publications Affected Table 1, Publications Affected Manual Type Service Manual Service Manual Engine ISX12G CM2180 EJ ISX12N CM2380 X120B Bulletin Number 4310682 5411406 Procedure Title Procedure Spark Plugs (Non-Shielded) Refer to Procedure 013016 (/qs3/pubsys2/x ml/en/procedure s/181/181-013016.html) Spark Plugs (Non-Shielded) Refer to Procedure 013016 (/qs3/pubsys2/x ml/en/procedure s/525/525-013016.html) Document History Date 2022-1-13 Details Module Created Last Modified: 13-Jan-2022 https://quickserve.cummins.com/qs3/pubsys2/xml/en/tsb/2022/tsb220009.html 2/2