No. 95-22-1

Service Bulletin Details

Public Details for: No. 95-22-1

Technical information for charging the high-voltage battery not possible/faulty.


- 2022 - 2021 -

Service
Technical Information
95/22
ENU
2797
2
Charging of the High-Voltage Battery Not Possible or Faulty, Error Messages After
Charging: Re-Program High-Voltage Charger (OBC) Control Unit (95/22)
Revision:
This bulletin replaces bulletin ATI Group 2 2202.1, dated April 29, 2022.
Vehicle Type:
Panamera 4 E-Hybrid (971) / Panamera 4 E-Hybrid Executive (971) / Panamera 4 E-Hybrid
Sport Turismo (971) / Panamera 4S E-Hybrid (971) / Panamera 4S E-Hybrid Executive (971)
/ Panamera 4S E-Hybrid Sport Turismo (971) / Panamera Turbo S E-Hybrid (971) / Panamera
Turbo S E-Hybrid Executive (971) / Panamera Turbo S E-Hybrid Sport Turismo (971)
Model Year:
2021
Equipment:
Charger 7.2 kW (M-Nr. KB2)
Concerns:
Control unit for high-voltage charger (OBC)
Information:
Various symptoms during or after charging the high-voltage battery, e.g.:
•
•
•
Charging of the high-voltage battery not possible or charging process is aborted
Check Engine light in the instrument cluster after charging or charging attempt active
Fault memory entry ’U112100 – Data bus – missing message (D1211D)’ stored in the fault memory
of the high-voltage charger (OBC) control unit
Action required: In the event of a customer complaint, re-program the high-voltage charger (OBC) control unit using
the PIWIS Tester with PIWIS Tester software version 40.900.050 (or higher) installed and the
corresponding programming code.
Information
The total time required for control unit programming is approx. 4 minutes.
Required tools
Tool:
•
•
Battery charger with a current rating of at least 90 A, e.g. VAS 5908 battery charger 90A. For
further information about the battery chargers to be used, see the corresponding Workshop Manual.
 Workshop Manual '270689 Charging vehicle electrical system battery'
9900 - PIWIS Tester 3 with PIWIS Tester software version 40.900.050 (or higher) installed
Preliminary work
WARNING
Independently electrically moved side windows and rear spoiler
•
Danger of limbs being trapped or severed
•
Risk of damage to components

Do not reach into the danger area.
AfterSales
Jun 30, 2022
Page 1 of 4
2
Service
2797
ENU
Technical Information
95/22

Keep third parties away from the danger area.

Do not move components or tools into the danger area.

Retract roll-up sun blinds on the rear side windows before starting programming or coding.
NOTICE
Fault entry in the fault memory and control unit programming aborted due to low voltage.
•
Increased current draw during diagnosis or control unit programming can cause a drop in voltage, which
can result in one or more fault entries and the abnormal termination of the programming process.

Before commencing work, connect a suitable battery charger with a charging current of at least 90 A to
the jump-start terminals in the engine compartment.
NOTICE
Control unit programming will be aborted if the Wi-Fi connection is unstable.
•
An unstable Wi-Fi connection can interrupt communication between PIWIS Tester and the vehicle communication module (VCI). As a result, control unit programming may be aborted.

During control unit programming, always connect the PIWIS Tester to the vehicle communication module
(VCI) using the USB cable.
NOTICE
Control unit programming will be aborted if the driver’s key is not detected.
•
If the driver’s key is not detected in the vehicle, programming cannot be started or will be interrupted.

Place the driver’s key with the back facing down into the front left storage compartment in the center
console to ensure a continuous radio link between the vehicle and the driver’s key.
Work Procedure: 1
Place the driver’s key with the back facing down
into the front left storage compartment in the center
console (emergency start tray) to guarantee a
continuous radio link between the vehicle and the
driver’s key  Emergency start tray.
2
Carry out general preliminary work for control unit
programming as described in  Workshop Manual
'9X00IN Basic instructions and procedure for control
unit programming - section on “Preliminary work”'.
Jun 30, 2022
Page 2 of 4
AfterSales
Emergency start tray
Service
Technical Information
95/22
ENU
2797
2
Re-programming high-voltage charger (OBC) control unit
Work Procedure: 1
The basic procedure for programming a control unit is described in the Workshop Manual 
Workshop Manual '9X00IN Basic instructions and procedure for control unit programming - section
on “Programming”'.
Specific information on control unit programming in the context of this Technical Information:
Required PIWIS Tester software version:
40.900.050 (or higher)
Type of control unit programming:
Control unit programming using the ’Campaign’
function in the Additional menu on the PIWIS Tester
by entering a programming code.
Programming code:
G2S3U
Programming sequence:
Read and follow the information and instructions
on the PIWIS Tester during the guided programming
sequence.
During programming, the high-voltage charger (OBC)
control unit is re-programmed and then re-coded
automatically.
Do not interrupt programming.
Programming time (approx):
4 minutes
Software version programmed during this
campaign:
1183
The software version information in the
programmed data record is based on the
specified PIWIS Tester software version.
Please note that this may be different in a
higher version.
•
Following control unit programming, the software
version can be read out of the high-voltage
charger (OBC) control unit from the ’Extended
identifications’ menu using the PIWIS Tester.
Procedure in the event of error messages
appearing during the programming
sequence:
 Workshop Manual '9X00IN Basic instructions and
Procedure in the event of a termination in the
control unit programming:
Repeat control unit programming by restarting
programming.
procedure for control unit programming - section on
“Troubleshooting”'.
AfterSales
Jun 30, 2022
Page 3 of 4
2
Service
2797
ENU
Technical Information
95/22
Concluding work
1
Carry out general rework for control unit programming as described in  Workshop Manual '9X00IN
Basic instructions and procedure for control unit programming using the PIWIS Tester - section on
“Rework”'.
Invoicing
For documentation and warranty invoicing, enter the working position and PCSS encryption specified
below in the warranty claim:
APOS
Labor operation
27972501
Programming high-voltage charger
I No.
PCSS encryption:
Location (FES5)
27970
High-voltage charger
Damage type (SA4)
1611
does not function
References:
 Workshop Manual '270689 Charging vehicle electrical system battery'
 Workshop Manual '9X00IN Basic instructions and procedure for control unit programming using the
PIWIS Tester'
Important Notice: Technical Bulletins issued by Porsche Cars North America, Inc. are intended only for use by professional automotive technicians who have attended Porsche service training
courses. They are written to inform those technicians of conditions that may occur on some Porsche vehicles, or to provide information that could assist in the proper servicing of a vehicle. Porsche special
tools may be necessary in order to perform certain operations identified in these bulletins. Use of tools and procedures other than those Porsche recommends in these bulletins may be detrimental to the
safe operation of your vehicle, and may endanger the people working on it. Properly trained Porsche technicians have the equipment, tools, safety instructions, and know-how to do the job properly and
safely. Part numbers listed in these bulletins are for reference only. The work procedures updated electronically in the Porsche PIWIS diagnostic and testing device take precedence and, in the event of a
discrepancy, the work procedures in the PIWIS Tester are the ones that must be followed.
© 2022 Porsche Cars North America, Inc.
Jun 30, 2022
Page 4 of 4
AfterSales


© dot.report 2024

Use of this information constitutes acceptance for use in an AS IS condition. There are NO warranties, implied or otherwise, with regard to this information or its use. Any use of this information is at the user's risk. It is the responsibility of user to evaluate the accuracy, completeness or usefulness of any information, opinion, advice or other content. EACH USER WILL BE SOLELY RESPONSIBLE FOR ANY consequences of his or her direct or indirect use of this web site. ALL WARRANTIES OF ANY KIND ARE EXPRESSLY DISCLAIMED. This site will NOT BE LIABLE FOR ANY DIRECT, INDIRECT or any other kind of loss.