TSB220192-092920
Service Bulletin Details
Public Details for: TSB220192-092920
This technical servicel bulletin was issued for fault code 1117. Fault code 1117 detects when the ecm did not have enough time to finish writing data before losing power. FC1117 will immediately go inactive at a normal engine start up. Fc1
- 9999 -
Models from 9999
9999 CUMMINS B6.7 |
9999 CUMMINS ISX12 |
9999 CUMMINS L9 |
9999 CUMMINS L9N |
9999 CUMMINS X12 |
9999 CUMMINS X15 |
Premature Battery Power loss: Fault Code 1117 Page 1 of 7 Technical Service Bulletin Technical Service Bulletin: Released Date: 29-Sep-2022 TSB220192 Premature Battery Power loss: Fault Code 1117 Premature Battery Power loss: Fault Code 1117 Warranty Statement The information in this document has no effect on present warranty coverage or repair practices, nor does it authorize TRP or Campaign actions. Contents Product Affected • • • • • • • • • • • • B6.7 CM2350 B121B B6.7 CM2450 B155B ISX12 CM2350 X102 L9 CM2350 L116B, L9 CM2350 L123B L9 CM2450 L126B L9N CM2380 L142B X12 CM2350 X119B X12 CM2450 X137B X15 CM2350 X114B X15 CM2350 X116B X15 CM2450 X124B X15 CM2450 X134B Issue Summary Symptom: • Fault Code 1117 ◦ Fault Code 1117 detects when the ECM did not have enough time to finish writing data before losing power. FC1117 will immediately go inactive at a https://quickserve.cummins.com/qs3/pubsys2/xml/en/tsb/2022/tsb220192.html 10/6/2022 Premature Battery Power loss: Fault Code 1117 Page 2 of 7 normal engine start up. FC1117 can have multiple counts of the code if the engine is continually losing power prematurely. Root Cause: • ECM power supply loss • ECM power ground Loss • Key Switch voltage drop Verification • ECM Power Ground Loss: Cummins Inc. prefers the ECM power ground is 4 or 5 wires that will be one the OEM J2 ground for the ECM to be grounded to the cylinder block. The cylinder block ground stud should be an M10 threaded stud on the cylinder block usually below or near the ECM and then from the cylinder block directly to the battery negative post. Note : Some applications may have an ECM case ground strap. This grounds only the housing of the ECM and does not ground internal connections. This is not a connection that would lead to Fault Code 1117. Figure 1, Grounding Strap. 1. ECM Power Supply Loss: The ECM power supply (See Figure 5) is the 4 or 5 wires https://quickserve.cummins.com/qs3/pubsys2/xml/en/tsb/2022/tsb220192.html 10/6/2022 Premature Battery Power loss: Fault Code 1117 Page 3 of 7 that will be on the OEM J2 power for the engine control module (ECM). Figure 2, Example Power Distribution Module. • Loose ECM ground connections will cause intermittent ECM power ground loss. The ECM ground connection is located on the cylinder block as a threaded stud below or near the ECM. https://quickserve.cummins.com/qs3/pubsys2/xml/en/tsb/2022/tsb220192.html 10/6/2022 Premature Battery Power loss: Fault Code 1117 Page 4 of 7 Figure 3, Example Grounding Wire Location. Figure 3 Items: 1. 2. 3. 4. 5. Fuel pump rear bracket. OEM installed bracket. Ground cable, stud, and nut. Power steering pump. Lubricating oil pan. • Ground noise issues can cause ECM power ground loss if Cummins Inc. grounding best practices are not followed. 2. ECM Power Supply Loss: The ECM power supply (See Figure 5) is the 4 or 5 wires that will be on the OEM J2 power for the engine control module (ECM). • a.Using an OEM Disconnect switch, sometimes referred to as a kill switch, E-Stop, etc., and/or not letting the ECM power down appropriately can cause a Fault Code 1117 indicating a premature power supply loss ◦ The ECM continues to write data and work after engine key off and needs uninterrupted power for a set time to finish. https://quickserve.cummins.com/qs3/pubsys2/xml/en/tsb/2022/tsb220192.html 10/6/2022 Premature Battery Power loss: Fault Code 1117 Page 5 of 7 Figure 4, Example Kill Switch. • Using a Power Distribution Module (PDM) can cause a premature power supply loss. Depending on application this may or may not be present. If present, A PDM is a module that can be used to control power on and off to a subset of the equipment or the whole engine. • If the ECM Power wiring is connected through the starter to the battery a power supply loss could be detected by the ECM. Note : CMI requires ECM power connected straight to battery from the ECM positive terminals on J2. https://quickserve.cummins.com/qs3/pubsys2/xml/en/tsb/2022/tsb220192.html 10/6/2022 Premature Battery Power loss: Fault Code 1117 Page 6 of 7 Figure 5, Example OEM wiring Schematic. 3. Key Switch Voltage Drop • Old or weak batteries weak batteries can cause a voltage drop at engine cranking events. ◦ Indicators of a weak battery: long crank or hard start up; despite engine starting the voltage drop could cause Fault Code 1117. • Loss of key switch signal or connection could cause voltage drops. Verify key switch hardware and or wiring is not loose. For the purpose of troubleshooting Fault Code 1117, the key switch of concern is the input signal from the OEM’s physical key switch to the ECM J2 connector. • Key switch signal should be uninterrupted without relays. Interruptions of the input signal could induce Fault Code 1117. https://quickserve.cummins.com/qs3/pubsys2/xml/en/tsb/2022/tsb220192.html 10/6/2022 Premature Battery Power loss: Fault Code 1117 Page 7 of 7 Figure 6, Key Switch Signal Example. Resolution • If any connections are found to be incorrectly routed or in need of repair, contact OEM. • For any malfunctions that are not covered under Cummins Inc. warranty, repair locations are to contact OEM for further repair direction. Document History Date 2022-9-13 Details Module Created Last Modified: 29-Sep-2022 https://quickserve.cummins.com/qs3/pubsys2/xml/en/tsb/2022/tsb220192.html 10/6/2022