V9324012073298_1
Service Bulletin Details
Public Details for: V9324012073298_1
Electrical system error message (yellow) with dtc P0BBD00 stored in battery regulation control module -j840- (diagnostic address 008c).
Models from 2023
2023 VOLKSWAGEN ID.4 |
Models from 2022
2022 VOLKSWAGEN ID.4 |
Models from 2021
2021 VOLKSWAGEN ID.4 |
Technical Service Bulletin 93-24-01 - Reduced Range Concern with Yellow Electrical System Error Message with P0BBD Transaction No: 2073298/1 Release date: 3/26/2024 Condition Applicable Vehicles Model(s) Year Eng. Code Trans. Code VIN Range From VIN Range To PR No. ID.4 2021 - 2023 All All All All LX0 Revision Table Instance Number Published Date Version Number 2073298/1 3/26/2024 93-24-01 Reason For Update Original publication. Customer Concern: • Electrical system error message (yellow) with the following DTC stored in the Battery Regulation Control Module -J840- (diagnostic address 008C): • P0BBD00: Hybrid Battery Pack Voltage Variation Exceeded Limit • A complaint of reduced or dropping range may also be present. If a vehicle presents a range complaint without the above DTC stored in the Battery Regulation Control Module -J840- (diagnostic address 008C), then this bulletin does not apply. For concerns relating to the degradation of the total capacity of the high-voltage battery due to aging, refer to Technical Service Bulletin 2071535. For other concerns related to range diagnosis, refer to Technical Service Bulletin 2071494. Page 1 of 3 © 2024 Volkswagen Group of America, Inc. All rights reserved. Information contained in this document is based on the latest information available at the time of printing and is subject to the copyright and other intellectual property rights of Volkswagen Group of America, Inc., its affiliated companies and its licensors. All rights are reserved to make changes at any time without notice. No part of this document may be reproduced, stored in a retrieval system, or transmitted in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, nor may these materials be modified or reposted to other sites, without the prior expressed written permission of the publisher. Technical Service Bulletin 93-24-01 - Reduced Range Concern with Yellow Electrical System Error Message with P0BBD Transaction No: 2073298/1 Release date: 3/26/2024 Technical Background In some high-voltage batteries there have been cells that demonstrate an increased self-discharge due to a production fault. An increased self-discharge in individual battery cells can lead to a reduction in overall battery capacity, and therefore a reduction of the range of the vehicle. In the case of a cell module replacement, certain steps must be carried out in order to reset the data in the Battery Regulation Control Module -J840- (diagnostic address 008C). Production Solution Improvements made to battery production process CW48/22. Service This procedure applies to vehicles with a Battery Regulation Control Module -J840- (diagnostic address 008C) with software version 1041. If the -J840- software is at a lower level than 1041, ensure all applicable campaigns are completed to bring the -J840- up to software version 1041. This procedure includes a reset of the data in the Battery Regulation Control Module -J840(diagnostic address 008C). This will prevent the “check cell equalization” test plan (performed in campaign 93P7) from incorrectly identifying cell modules as defective that have already been replaced. 1. Complete the test plan populated in GFF for DTC P0BBD00. • Only replace cell module(s) as directed by this GFF test plan’s results, and in accordance with the instructions outlined in the repair manual. 2. Perform GFF > Special Functions > software configuration > via action code > 8CHVHDM1041 3. Perform GFF > Test plan > Select self test > 0019 – Establish bus sleep mode 4. Perform GFF > Special Functions > software configuration > via diagnostic address > 008C 5. Perform GFF > Test Plan > Select self test > 0025 – VKMS adaptation Page 2 of 3 © 2024 Volkswagen Group of America, Inc. All rights reserved. Information contained in this document is based on the latest information available at the time of printing and is subject to the copyright and other intellectual property rights of Volkswagen Group of America, Inc., its affiliated companies and its licensors. All rights are reserved to make changes at any time without notice. No part of this document may be reproduced, stored in a retrieval system, or transmitted in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, nor may these materials be modified or reposted to other sites, without the prior expressed written permission of the publisher. Technical Service Bulletin 93-24-01 - Reduced Range Concern with Yellow Electrical System Error Message with P0BBD Transaction No: 2073298/1 Release date: 3/26/2024 Warranty Information only. Required Parts and Tools Not applicable. Additional Information All part and service references provided in this Technical Bulletin are subject to change and/or removal. Always check with your Parts Dept. and Repair Manuals for the latest information. Page 3 of 3 © 2024 Volkswagen Group of America, Inc. All rights reserved. Information contained in this document is based on the latest information available at the time of printing and is subject to the copyright and other intellectual property rights of Volkswagen Group of America, Inc., its affiliated companies and its licensors. All rights are reserved to make changes at any time without notice. No part of this document may be reproduced, stored in a retrieval system, or transmitted in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, nor may these materials be modified or reposted to other sites, without the prior expressed written permission of the publisher.