Recalls

Recall R/2018/237

  • UK Recall: Control logic which monitors the charging control program fails to divert electrical power away from capacitor in the event of a fault
    >On the subject vehicles the control logic which monitors the charging control program fails to divert the electrical power away from the capacitor when a fault is detected within the capacitor circuit. this can cause a short circuit inside the dcdc converter and could cause the engine to stall or overheating of the dcdc converter itself which could cause a fire. the fault is accompanied by the ?i-eloop? warning light being illuminated on the instrument cluster along with the ?i-stop? warning light flashing the engine may in some circumstances stall and fail to restart. in extreme cases the dcdc converter could overheat and cause a fire

    Corrective Action:
    Reprogram the pcm with the correct control logic. if error code ?u3000: 49-dcdc? is stored ? the dcdc converter must also be replaced.


    965 Affected Units 🚙🚙🚙
    From VIN MMZDK******109070 to MMZDK******230228

  • © dot.report 2024

    Use of this information constitutes acceptance for use in an AS IS condition. There are NO warranties, implied or otherwise, with regard to this information or its use. Any use of this information is at the user's risk. It is the responsibility of user to evaluate the accuracy, completeness or usefulness of any information, opinion, advice or other content. EACH USER WILL BE SOLELY RESPONSIBLE FOR ANY consequences of his or her direct or indirect use of this web site. ALL WARRANTIES OF ANY KIND ARE EXPRESSLY DISCLAIMED. This site will NOT BE LIABLE FOR ANY DIRECT, INDIRECT or any other kind of loss.