UK Recall: Control logic which monitors the charging control program fails to divert electrical power away from capacitor in the event of a fault
>On the subject vehicles the control logic which monitors the charging control program fails to divert the electrical power away from the capacitor when a fault is detected within the capacitor circuit. this can cause a short circuit inside the dcdc converter and could cause the engine to stall or overheating of the dcdc converter itself which could cause a fire. the fault is accompanied by the ?i-eloop? warning light being illuminated on the instrument cluster along with the ?i-stop? warning light flashing the engine may in some circumstances stall and fail to restart. in extreme cases the dcdc converter could overheat and cause a fire
Corrective Action:
Reprogram the pcm with the correct control logic. if error code ?u3000: 49-dcdc? is stored ? the dcdc converter must also be replaced.
965 Affected Units 🚙🚙🚙
From VIN MMZDK******109070 to MMZDK******230228