Jayco Eagle Super Lite 2012
Vehicle Details: Recalls, Consumer Complaints, Service Bulletins
Below you will find all available information on the 2012 JAYCO Eagle Super Lite.
Manufacturer | Known WMI(s) | Fuel Type |
---|---|---|
JAYCO |
Use the box here to look up VINs from JAYCO as well as other manufacturers
Sub-models: - Eagle Super Lite Travel Trailer -
-
Are there recalls for the 2012 JAYCO Eagle Super Lite?
- There are 3 recall(s) for the 2012 JAYCO Eagle Super Lite, additional information is below.
Recall 127623 [USA]: In the event of a fire, if the fire extinguisher does not function properly, it can increase the risk of injury.
Recall 94893 [USA]: This could result in a fire, injury or death.
Recall 2011404 [Canada]: Electrical
To ensure accuracy and for your safety, it is recommended to do a free VIN recall check here or here [USA] - UK - Canada.
Bulletins are notices put out by manufacturers in conjunction with the NHTSA to notify the public of manufacturing issues or changes.
- INC 22-067 - EQUIPMENT:OTHER:OWNERS/SERVICE/OTHER MANUAL : Jayco and entegra coach storage tips. Instructions for storing jayco and entegra coach diesel pushers.
- 22-043 - STRUCTURE: Standard repair instructions detailing how to repair a unit with a crack in the sidewall near the slideout.
- SRP - 22-043 - EQUIPMENT:MECHANICAL:SLIDE-IN CAMPER: (srp) standard repair procedure for crack forming at the front bottom corner of the off door side (ods) or door side (ds) front slide out on certain jayco 5th wheel travel trailers.
- INC 20-007 - EQUIPMENT: Informational bulletin for repair that requires the removal of pullout cabinet extension drawers.
- TSB-11-011 - STRUCTURE:FRAME AND MEMBERS:UNDERBODY SHIELDS: Jayco: see document search button for owner letter. The rear cross member having an underbelly shield added. *pe
Crash | Fire | Towed | Injured | Deaths | Failure Date |
---|
No | No | N | None | None | 20140205 |
Draining my black water tank, and connected a hose to tank fresh water scrubber. Water started running onto ground from underneath unit. Shut off water, and found a hidden in line check valve model 571 from b and b mfg had malfunctioned, allowing water to flood the furnace/waterheater compartment, bedroom floor, and other areas. Furnace is 12v, but wh is dual gas/110v, thus had the wh been operating on 110, and water got to the elect wires, my wife, who was walking barefooted in br, could have been hurt. B and b requires the mfg to place their warning tag at inlet and not enclose the valve in a hidden area, for it can " vent water during normal functioning." neither of these instructions from b and b occurred on my unit. I have blogged with others on this issue, and have found the same valve problem, dateing back to 2010, on both jayco and other mfgs. I'am the second owner, so warranty does not apply. Jayco corporate service people said they were sorry about the absent tag, and to just do away with the valve. What about the hundreds of other owners with this same valve? Like me, the problem is found, with out any warning, *tr ## vin passed ## jayco eagle series 298rls ##