13-BE-007
Service Bulletin Details
Public Details for: 13-BE-007
Summary to be provided on a future date.
- 2014 -
Models from 2014
2014 HYUNDAI EQUUS |
(8) HYU na R 11 GROUP nEW THlnKlnG. nEW POSSIBILITIES. BODY ELECTRICAL Technical Service Bulletin SUBJECT: DATE AUGUST 2013 NUMBER 13-BE-007 MODEL(S) EQUUS (VI) 2014 EQUUS SMART KEY /CARD PROGRAMMING & OPERATION Description: This bulletin describes the procedure for the programming/teaching and operation of Equus Smart Key Cards and Conventional Smart Keys . *NOTE Once the 1st key is programmed, the customer's 2nd and 3rd keys must be programmed at the same time or they will not start the vehicle. *NOTE Before attempting the key programming procedure, call Techline to obtain the 6 digit PIC pin code. Techline phone number: 800-325-6604. !Applicable Vehicles: 2014MY Equus (VI) 5.0L Warranty Information: Normal warranty applies . Circulate To: General Manager, Service Manager, Parts Manager, Warranty Manager, Service Advisors , Technicians , Body Shop Manager, Fleet Repair SUBJECT: 2014 EQUUS SMART KEY/CARD PROGRAMMING & OPERATION Main Features: Conventional Smart Key 4 3 Card Type Smart Key 2 Function Keys * No button * 4 Buttons Mechanical Key * Press and hold the release button * Push and hold the release lever 3 Battery 2 * Battery Specification : CR2032 I* NOTE ~----ii * Battery Specification : CR2412 I 11--~~~~~~~~~~~~~~~~~~~~~~~-, Up to 3 Smart Keys (including card type Smart Keys) can be registered to the vehicle . They can be a combination of 2 Conventional Smart Keys and 1 Smart Key Card, or 2 Smart Key Cards and 1 Conventional Smart Key. TSB #: 13-BE-007 Page 2 of 8 SUBJECT: 2014 EQUUS SMART KEY /CARD PROGRAMMING & OPERATION Functions: Action Function To Lock Door Press the door handle button Press the Door Lock button on the smart key Door To Unlock Door Put your hand on the driver's outside door handle Press the Door Unlock button on the Smart Key Press the Trunk Unlock button on the smart key for more than one second To Open Trunk Trunk Press the trunk release button on the trunk lid Use the mechanical key Press the TRUNK button or power trunk main control button under the steering wheel Button Engine Start Panic To Close Trunk Lower the trunk lid and press down until it locks Engine Start Press the engine start button with the key inside the vehicle Engine Stop Press the engine start button while the engine is running - TSB #: 13-BE-007 Press the PANIC button on the smart key Conventional Smart Key Card Type Smart Key • • • • • • • • • • • • • x • x x • • • • • • x Page 3 of 8 SUBJECT: 2014 EQUUS SMART KEY /CARD PROGRAMMING & OPERATION Smart Key Card/Conventional Smart Key Programming Procedure: *NOTE Before proceeding, have all 3 Smart Keys ready and the 6 digit PIC pin code obtained from Techline. Techline phone number: 800-325-6604. 1. Connect the DLC cable of the VCI to the data link connector located under the left side of dash. 2. From the System Screen , select "PIC" and click "OK" ; "t¥t: 0 !iIG>l4JH9EU074998 •• " ! H " -=-~ • ::J I Select System , Selected System Fault Code Searching TSB # : 13-BE-007 Page 4 of 8 SUBJECT: 3. 2014 EQUUS SMART KEY /CARD PROGRAMMING & OPERATION Click the "Vehicle S/W Management" tab. Select "Option Treatment" and then click "Smart Key Code Saving ". Pr•i>-,.tJon ..l System Identification ..> Neutralization Mode -' SMK STATUS INFORMATION J FOB KEY STATUS INFORMATION ...> Sm.act Key Code Saving \ol Current FOB Key Ch~k \,) Serial Communication Line Ch~ck Antenna St.JIUS Check 4. Turn the ignition OFF and press "OK" on the GOS . Smart KcyCo4c ~II [ Smal'! Key Code SllYlngJ rco ndlllon J 1 10011' Ptease havt!F08kll)'lotncnindpr11s1fOKl but:on 5. Enter the 6 digit PIC pin code obtained from Techline and click "OK". lnpul PIN code and P!BS!I IOKl IHJ!lon TSB # : 13-BE-007 Page 5 of 8 SUBJECT: 2014 EQUUS SMART KEY /CARD PROGRAMMING & OPERATION 6. Have all 3 Smart Keys ready and click "OK". 7. Click "OK" and within 5 seconds use the first Smart Key to press and hold the Start Stop button. Keep the button pressed in fully for one or two seconds , then release . SmartKQytolilo5aVl:ng - -- - - - ..,.,, - -- - - - [Qt- [Smart Key Code Sw.ing I 1sl key teachl ng Ciiek [OKI. and men 111es'i sse(Start Stop Bur.on) [ Smart Key Code Saving J using tst FOBwlthln5 setonds {DOnolU'iEIYourfrngerropressSSB,tlutuseFOBttsetr) Conllnue? (OKICANCEL) 1st key teaching Click [OK[, and then press SSB(Start Stop Button) using 1st FOB w ithin 5 seconds. (Do not use yo uninger to press SS B, but use FOB itse lf) Continue? (OK/CANCEL) *NOTE Do not use your finger to press the Stop Start button. Use the Smart Key or Key Card to fully press the button as shown. When teaching the Smart Key Card , use the upper left corner of the card to press the Start Stop button. It may be marked with red tape. TSB #: 13-BE-007 Page 6 of 8 SUBJECT: 8. 2014 EQUUS SMART KEY /CARD PROGRAMMING & OPERATION After successfully teaching the 1 st key , this screen will appear. Click "OK" and proceed to teach the 2 nd key. 5mlUIKtyCodo51!1Wlg - -- - JSmartKeyCOde Sa¥1ng] 1stkE"t'teathtngcompletedl Clkk IOIQ, and tnen pren SSB(Slirt 5'.op Buton) usJng2ndFO B W1ttun ~ seconc1s. (Oo not useyournnge11opressSSB,but useF09Hsell) Contmur? (OKIC>.NCElJ 9. When the 2 nd key teaching is complete , press "OK" and teach the 3 rd and final key. 1smar1 KevCodeSarlng ] 2ndf.v yteilctl!ngccmpletedl Click 101(). and lh11n press SSB(St.lrt Slop Bllilon) usmg3rd FOBWlthln5HtoniJs (Oon01useyou1Mgertop1euSSEl,but use FOSlt$ell) conunue?(OIQCANCEW liiil 10. After successfully teaching the screen will appear. Click "OK". TSB # : 13-BE-007 3rd ml key, this Page 7 of 8 SUBJECT: 11 . 2014 EQUUS SMART KEY /CARD PROGRAMMING & OPERATION A screen showing that the Smart Key teaching has been completed will open and will display that 3 Smart Keys have been taught. Click "OK". Smart Key Cod• S1Mn11 - - - - I Smart Key Colle S;r,ino I Smart Kevt&athlng completed! Number 0fl1ugh!F09ktys : 3 Iii) 12. Confirm operation of all Conventional Smart Keys and Smart Key Cards. If Smart Keys are inoperative , refer to Steps 3-11 to repeat the procedure. TSB # : 13-BE-007 Page 8 of 8