TAIB0842

Service Bulletin Details

Public Details for: TAIB0842

Summary to be provided on a future date.


- 9999 -

Models from 9999
9999 EATON EATON
'
Service Bulletin - Product
SUPPORT
Powering Business Worldwide
Subject: New Push-In Style Speed Sensors
Document Number: TAIB0842
Date: November 19, 2012
Updated:
Description:
A redesigned speed sensor has been released into production and service. External
changes include a sensor body designed to minimize corrosion seizing and integrated
retaining clip that will not distort the sensor when the retaining cap screw is tightened .
Sensor output signal , harness connector interface and 14142 0-ring are all
interchangeable with current design sensors .
New Sensor
Current Sensor
For drive socket clearance during installation , a new external Torx head retaining cap
screw will also be included in the sensor service kits .
Page 1of3
Service Bulletin - Product
X-8-0832M:
• Replaces X-B-OB01 M
(MB x 1.25 x 12mm)
• Use E12 external Tone drive socket for
installation
• Torque spec is 7-9 lbs. ft. (9-12 Nm)
X-8-0832M - HD Output Sensors
X-8-460:
• Replaces X-BC-409
(0.250"- 20 x 0.625")
• Use EB external Tone drive socket for
installation
• Torque spec is 4-6 lbs. ft. (6-B Nm)
X-8-460 - Input & Mainshaft Sensors
(MD output sensors)
Page 2 of 3
Service Bulletin - Product
UltraShift PLUS Clutch Housing Speed Sensor
The sensor retaining clip must be removed and discarded when replacing the clutch
housing speed sensor on early production UltraShift PLUS models. A clearance issue
between the new retaining clip and clutch housing prevents the sensor from being fully
seated, resulting in repeat speed sensor fault codes. The hex drive cap screw
(0.250"-20x 0.625") with washer must be reused when the retaining clip is removed .
Early production sensor
without retaining clip
Speed Sensor
New sensor with clip removed
New sensor installed
without retaining clip
Warranty Information:
N/A
The material contained in this bulletin is product improvement information. Eaton Corporation is not committed to,
or liable for, canvassing existing products.
FSUD: 2012-FSUD-1913
Page 3 of 3


© dot.report 2024

Use of this information constitutes acceptance for use in an AS IS condition. There are NO warranties, implied or otherwise, with regard to this information or its use. Any use of this information is at the user's risk. It is the responsibility of user to evaluate the accuracy, completeness or usefulness of any information, opinion, advice or other content. EACH USER WILL BE SOLELY RESPONSIBLE FOR ANY consequences of his or her direct or indirect use of this web site. ALL WARRANTIES OF ANY KIND ARE EXPRESSLY DISCLAIMED. This site will NOT BE LIABLE FOR ANY DIRECT, INDIRECT or any other kind of loss.