PIC4995A
Service Bulletin Details
Public Details for: PIC4995A
Summary to be provided on a future date.
- 2010 - 2009 - 2008 - 2007 - 2006 -
Models from 2010
2010 PONTIAC SOLSTICE |
2010 SATURN SKY |
Models from 2009
2009 PONTIAC SOLSTICE |
2009 SATURN SKY |
Models from 2008
2008 PONTIAC SOLSTICE |
2008 SATURN SKY |
Models from 2007
2007 PONTIAC SOLSTICE |
2007 SATURN SKY |
Models from 2006
2006 PONTIAC SOLSTICE |
File in Section: Service Bulletin Bulletin No.: Date: PIC4995A January, 2014 PRELIMINARY INFORMATION Subject: HVAC Temperature Goes Full Hot When One Click Off Full Cold Models: 2006 - 2010 Pontiac Solstice 2007 - 2010 Saturn SKY This PI was superseded to update model years. Please discard PIC4995. The following diagnosis might be helpful if the vehicle exhibits the symptom(s) described in this PI. Condition/Concern Some customers may complain that the temperature will go to full hot when they turn the temperature control one click off of full cold. The control head is defaulting to Emergency Mode (this provides HOT air to clear the windshield in Defrost mode). This will happen if the feedback voltage for the air temperature actuators are out of range. Recommendation/Instructions Locally obtain a 60 to 68 ohm, 1/2 watt resistor, and install it in-line with circuit 1688, pin F of the HVAC control head. Install the resistor just behind the HVAC control head. Please follow this diagnostic or repair process thoroughly and complete each step. If the condition exhibited is resolved without completing every step, the remaining steps do not need to be performed.