Special Instruction
Oxygen Sensor Calibration Procedure for the CT Vocational Trucks{7000}
Media Number -REHS9183-00
Publication Date -2014/04/21
Date Updated -2014/04/21
i05781758
Oxygen Sensor Calibration Procedure for the CT Vocational Trucks
{7000}
SMCS - 7000
On Highway Truck:
CT660 (S/N: TGA1-UP; TGD1-UP; TJD1-UP; TEJ1-UP; TRK1-UP; TKL1-UP; TEM1-UP; TEP1UP; TGR1-UP; TGS1-UP; TJS1-UP; TGT1-UP; TGW1-UP; TSW1-UP; TEY1-UP; TSY1-UP; TEZ1UP; TGZ1-UP)
Introduction
This Special Instruction explains the Oxygen Sensor (O2S) Calibration Procedure that must be followed when
replacing or calibrating the O2S on the CT Vocational trucks.
Parts Information
Table 1
Required Equipment
QTY
Version Number
Description
1
Build v38.1.21.201402031337
Engine Diagnostic Software
Procedure
https://sisweb.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sis...
6/9/2016
Media Search - REHS9183 - Oxygen Sensor Calibration Procedure for the CT Vocational... Page 2 of 6
Illustration 1
g03666335
NOTICE
The O2S needs to be installed in the exhaust before calibrating the
sensor (Illustration 1).
Illustration 2
g03666347
1. Connect Personal Computer (PC) with engine diagnostic software. Turn Key ON, Engine OFF (KOEO).
2. Clear exhaust fumes by running the Relative Compression Test before calibrating the O2S. Disregard
Relative Compression Test results (Illustration 2).
https://sisweb.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sis...
6/9/2016
Media Search - REHS9183 - Oxygen Sensor Calibration Procedure for the CT Vocational... Page 3 of 6
Illustration 3
g03666348
3. Open O2 Sensor Calibration Procedure (Illustration 3).
Illustration 4
g03666351
4. Press the Start O2 Sensor Calibration button (Illustration 4).
Note: Calibration takes about 5 minutes and 40 seconds to complete.
Illustration 5
g03666352
5. When calibration is complete, a popup message will display O2 Sensor Calibration: Test Completed,
Successful, press OK button (Illustration 5).
https://sisweb.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sis...
6/9/2016
Media Search - REHS9183 - Oxygen Sensor Calibration Procedure for the CT Vocational... Page 4 of 6
Illustration 6
g03666354
6. Reset Parameters ONLY if a new O2S is installed (Illustration 6):
◦ 99520 (Set to 0)
◦ 99530 (Set to 0)
◦ 99540 (Set to 0)
◦ 99550 (Set to Normal 780 C)
https://sisweb.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sis...
6/9/2016
Media Search - REHS9183 - Oxygen Sensor Calibration Procedure for the CT Vocational... Page 5 of 6
Illustration 7
g03666355
Note: Not all calibrations have the Parameters in lower part of window as described in previous Step (Illustration
7).
https://sisweb.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sis...
6/9/2016
Media Search - REHS9183 - Oxygen Sensor Calibration Procedure for the CT Vocational... Page 6 of 6
Illustration 8
Copyright 1993 - 2016 Caterpillar Inc.
g03666359
Thu Jun 9 12:27:30 CDT 2016
All Rights Reserved.
lanets
Private Network For SIS Licensees.
https://sisweb.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sis...
6/9/2016


© dot.report 2024

Use of this information constitutes acceptance for use in an AS IS condition. There are NO warranties, implied or otherwise, with regard to this information or its use. Any use of this information is at the user's risk. It is the responsibility of user to evaluate the accuracy, completeness or usefulness of any information, opinion, advice or other content. EACH USER WILL BE SOLELY RESPONSIBLE FOR ANY consequences of his or her direct or indirect use of this web site. ALL WARRANTIES OF ANY KIND ARE EXPRESSLY DISCLAIMED. This site will NOT BE LIABLE FOR ANY DIRECT, INDIRECT or any other kind of loss.