ITB16-033a

Service Bulletin Details

Public Details for: ITB16-033a

2017 qx30; main 12 volt battery testing with midtronics gr8 or exp800 this bulletin has been amended to update the service information for main 12 volt battery testing. Please discard previous versions of this bulletin.


- 2017 -

Models from 2017
2017 INFINITI QX30
Classification:
Reference:
Date:
EL16-031a
ITB16-033a
October 10, 2016
2017 QX30; MAIN 12 VOLT BATTERY TESTING
WITH MIDTRONICS GR8 OR EXP800
This bulletin has been amended to update the Service Information for main 12 volt battery testing.
Please discard previous versions of this bulletin.
APPLIED VEHICLES:
2017 QX30 (H15)
SERVICE INFORMATION
When testing the main 12V battery of an Applied Vehicle with the Midtronics GR8 or EXP800, the test leads
must be connected directly to the posts on the main 12V battery (NOT the remote terminal check points) to
avoid incorrect CCA measurements.

Please see Figure 1 and Figure 2 on page 2 for correct connections to the 12 volt main battery.
IMPORTANT: Do not contact any surrounding components when connecting the test leads.
CAUTION: Never connect the Midtronics GR8 or EXP800 as shown in Figure 4 on page 2. This can damage
the pyro fuse connector.
NOTE: The remote terminal check points can be used for all other battery charging or voltage checking
procedures, but will give inaccurate CCA measurements due to voltage drops between them and the main 12V
battery.
Infiniti Bulletins are intended for use by qualified technicians, not 'do-it-yourselfers'. Qualified technicians are properly trained
individuals who have the equipment, tools, safety instruction, and know-how to do a job properly and safely. NOTE: If you believe
that a described condition may apply to a particular vehicle, DO NOT assume that it does. See your Infiniti retailer to determine if this
applies to your vehicle.
1/2

Connect the Midtronics GR8 or EXP800 as shown in Figure 1.
Connect at these
points.
Main 12V battery
Remote terminal check point:
Do not connect at this point
for testing.
Front of vehicle
Figure 1
Make connection to the right
of the pyro fuse connector.

Figure 2 shows a correct positive battery
terminal connection.
CAUTION:

Never connect the Midtronics GR8 or EXP800
to the positive battery terminal as shown in
Figure 3 or 4.

The pryo fuse may be damaged by the
open/close operation of the clamp.
Pyro fuse
connector
Figure 2
CAUTION: If clamp is connected as
shown the pyro fuse may be damaged by
the open/close operation of the clamp.
Figure 3
Figure 4
2/2
ITB16-033a


© dot.report 2024

Use of this information constitutes acceptance for use in an AS IS condition. There are NO warranties, implied or otherwise, with regard to this information or its use. Any use of this information is at the user's risk. It is the responsibility of user to evaluate the accuracy, completeness or usefulness of any information, opinion, advice or other content. EACH USER WILL BE SOLELY RESPONSIBLE FOR ANY consequences of his or her direct or indirect use of this web site. ALL WARRANTIES OF ANY KIND ARE EXPRESSLY DISCLAIMED. This site will NOT BE LIABLE FOR ANY DIRECT, INDIRECT or any other kind of loss.