K10075112

Service Bulletin Details

Public Details for: K10075112

Remote control central door lock, programming; key fob cannot be programmed or does not work after programming - model year 2018 and newer


- 2019 - 2018 -

Solution K10075112
Thursday, November 1, 2018 7:14:24 PM CET
Mack Models
Mack Model
TE-TerraPro , LR , LEU , MRU-TerraPro , GR-Granite , PI-Pinnacle , AN-Anthem ,
CHU-Pinnacle, Axle back , CXU-Pinnacle, Axel forward , GU-Granite , TD-Titan
Volvo Models
Volvo Model
VNR , VNX , VNL , VNM , VHD , VAH
Engine family
Engine family
11L Engine , 13L Engine , MP7 , MP8
Emission Standard
Emission Standard
2018 , OBD2017
** SOLUTION **
Title
Remote Control Central Door Lock, Programming; Key Fob Cannot Be Programmed Or
Does Not Work After Programming - Model Year 2018 And Newer
Cause
Technicians cannot achieve key fob programming mode due to the ECU's extended
power down time.
Solution
Due to the ECU's extended power down time it is recommended to move the ignition
switch to the drive position and remove the ingnition fuse 4 times as an alternative to
cycling the ignition switch 4 times. Doing this will power down the system faster so this
step can be completed within the 15 second time frame. The remaining steps are as
follows.
1. The direction indicator lamps remain on and the system is now ready to be
programmed.
Note: The instrument cluster does not indicate programming mode.
2. Press button 1 or 2 on the original remote control.
Note: It is recommended that at least one remote control to be secured at all times,
to avoid the replacement of the module-remote control pair, if both original remote
controls are missing.
Note: This step is a security feature.
3. The direction indicator lamps turn off for approx. 1 second to indicate that the module
has recognized the original remote control.
Note: No reprogramming is possible without an original remote control.
4. Press button 1 or 2 on each remote control that is desired to be programmed.
5. The direction indicator lamps go out for approx. 1 second to indicate that the new
remote control has been added.
6. To program the next remote control repeat Step 4. The system will exit programming
status after 15 seconds if no additional remote controls are programmed. This is also the
maximum time between activating the remote control within the programming cycle.
The system will also exit after eight remote controls are programmed.
7. When the remote control returns to the 'Normal' mode, If no buttons are pressed, then
the last remote control programmed, remains current for the system.
Note: Due to the security feature, all desired remote controls to be programmed must be
programmed, before the programming mode is exited into the Normal mode. To add a
new remote control and keep the previous ones, all steps must be taken again having all
the controls ready. The module starts each programming process anew.
Solution visibility
Dealer distribution
Function(s)/component(s) affected
Function affected
FSB
, immobiliser , doors
Function Group
Function Group
364 electrical item
Customer effect
Main customer effect
calibration/programming/pairing/missing operation , locking/unlocking
Administration
Author
A241298
Dealer ID
A241298
Last modified by
A241298
Creation date
04-10-2018 15:10
Date of last update
23-10-2018 21:10
Review date
02-04-2019 00:04
Status
Published
Variantes Kola
3AX - DOOR LOCK CAB
LOCK-CTL - CENTRAL DOOR LOCKING , LOCK-REM - CAB DOOR LOCK,
EXTERNAL REMOTE CONTROL , LOCK-ALL - CENTRAL DOOR LOCK. + CUT
OF THE ELECTRICITY OF THE TRUCK.


© dot.report 2024

Use of this information constitutes acceptance for use in an AS IS condition. There are NO warranties, implied or otherwise, with regard to this information or its use. Any use of this information is at the user's risk. It is the responsibility of user to evaluate the accuracy, completeness or usefulness of any information, opinion, advice or other content. EACH USER WILL BE SOLELY RESPONSIBLE FOR ANY consequences of his or her direct or indirect use of this web site. ALL WARRANTIES OF ANY KIND ARE EXPRESSLY DISCLAIMED. This site will NOT BE LIABLE FOR ANY DIRECT, INDIRECT or any other kind of loss.