This technical service bulletin describes the verification and resolution of a complaint of engine will not start. When attempting to communicate with insite? Electronic service tool, error 5080 - electronic control module (ecm) rom booted


- 9999 -

INSITE Electronic Service Tool Error 5080 - Electronic Control Module (ECM) ROM B...
Page 1 of 4
Technical Service Bulletin
Technical Service Bulletin:
Released Date: 20-Jun-2019
TSB150120
INSITE Electronic Service Tool Error 5080 - Electronic Control Module (ECM)
ROM Booted and in a Password Protected State
INSITE Electronic Service Tool Error 5080 Electronic Control Module (ECM) ROM Booted
and in a Password Protected State
Warranty Statement
The information in this document authorizes specific changes to the repair practice for
failures covered under product warranty coverages.
Contents
Issue
Complaint of engine will not start. When attempting to communicate with INSITE™
electronic service tool, Error 5080 - Electronic Control Module (ECM) ROM Booted is
displayed. Upon completion of recalibration to address the ROM boot issue, the ECM is
in a password protected state.
Verification
Product Affected
• ISL G CM2180
• ISX12 G CM2180 EJ
• ISB6.7 G CM2180 B118
Connect to the ECM. See corresponding Service Manual. Refer to Procedure 019-031
(/qs3/pubsys2/xml/en/procedures/45/45-019-031-tr-islg.html)in section 19.
INSITE™ electronic service tool Error 5080 will be present if the ECM is ROM booted.
See Figure 1 below.
After the ECM has been recalibrated, the ECM will be in a password protected state. See
https://quickserve.cummins.com/qs3/pubsys2/xml/en/tsb/2015/tsb150120.html
6/21/2019
INSITE Electronic Service Tool Error 5080 - Electronic Control Module (ECM) ROM B...
Page 2 of 4
Figure 2 below.
Figure 1, Error 5080
https://quickserve.cummins.com/qs3/pubsys2/xml/en/tsb/2015/tsb150120.html
6/21/2019
INSITE Electronic Service Tool Error 5080 - Electronic Control Module (ECM) ROM B...
Page 3 of 4
Figure 2, ECM In Password Protected State
Resolution
If the ECM has been ROM booted and is in password protected state after recalibration,
replace the ECM.
See corresponding Service Manual. Refer to Procedure 019-031
(/qs3/pubsys2/xml/en/procedures/45/45-019-031-tr-islg.html)in section 19.
Note : This does not include ROM booted events that occur while updating the
ECM calibration.
Inspect the engine and driveline mounts for signs of wear, see equipment manufacturer
service information. If failed engine or driveline mounts are found, please contact the
original equipment manufacturer (OEM).
ECM replacement is warrantable only if coverage is available for an ECM failure.
Table 1, Associated Procedures
Engine Model
Procedure Title
Procedure
Number
https://quickserve.cummins.com/qs3/pubsys2/xml/en/tsb/2015/tsb150120.html
Bulletin Number
6/21/2019
INSITE Electronic Service Tool Error 5080 - Electronic Control Module (ECM) ROM B...
Page 4 of 4
Table 1, Associated Procedures
Engine Model
Procedure Title
Procedure
Number
Bulletin Number
ISX12 G CM2180
EJ
Electronic Control
Module (ECM)
Reference
Procedure 019031
4310682
ISL G CM2180
Electronic Control
Module (ECM)
Reference
Procedure 019-031
4021649
Electronic Control
Module (ECM)
Reference
Procedure 019-031
5411104
ISB6.7 G CM2180
B118
Document History
Date
Details
2015-7-24
Module Created
2019-6-10
added table 1
Last Modified: 20-Jun-2019
https://quickserve.cummins.com/qs3/pubsys2/xml/en/tsb/2015/tsb150120.html
6/21/2019


© dot.report 2024

Use of this information constitutes acceptance for use in an AS IS condition. There are NO warranties, implied or otherwise, with regard to this information or its use. Any use of this information is at the user's risk. It is the responsibility of user to evaluate the accuracy, completeness or usefulness of any information, opinion, advice or other content. EACH USER WILL BE SOLELY RESPONSIBLE FOR ANY consequences of his or her direct or indirect use of this web site. ALL WARRANTIES OF ANY KIND ARE EXPRESSLY DISCLAIMED. This site will NOT BE LIABLE FOR ANY DIRECT, INDIRECT or any other kind of loss.