LI83.10-N-071291

Service Bulletin Details

Public Details for: LI83.10-N-071291

Fault code B105C07 the actuator motor for the air recirculation flap has a malfunction. There is a mechanical fault current and stored in the aac and / or B113600 the measurement run for actuator motors for air flaps has a malfunction.


- 2020 -

Air recirculation flap malfunctions with fault code B105C07 and / or B113600 in ACC control units
Topic number
LI83.10-N-071291
Version
1
Function group
83.10 Ventilation
Date
06-02-2020
Validity
Model 907
Reason for change
Reason for block
Complaint:
Fault Code B105C07 the actuator motor for the air recirculation flap has a malfunction.
There is a mechanical fault current and stored in the AAC.
and / or
B113600 the measurement run for actuator motors for air flaps has a malfunction.
Cause:
Under analysis
Normalization lost for the air conditioning flap actuators
Remedy:
Remedy 1
1. Connect XENTRY diagnosis and attempt normalization of the flap actuator motors. If normalization is successful
procedure is complete, if not proceed to step 2
2. If normalization is unsuccessful, continue to Remedy 2.
Remedy 2
1. Switch off ignition
2. Remove passenger foot well cover and tool kit to access the recirculation flap actuator motor (see: remedy 2 motor
location.jpg)
3. Remove the flap actuator motor from heater case with suitable tool (AR83.10-D-2041TS) (see: remedy 2 motor removal.jpg)
4. Check flap linkage for blockage by hand. If unimpeded movement is noted, reinstall the recirculation flap actuator
motor with the linkage in horizontal orientation (middle of sweep) (see: remedy 2 linkage orientation)
5. Repeat normalization of the flap actuators via XENTRY diagnosis
6. Erase stored faults
06-02-2020 3:27 PM
© Copyright Mercedes-Benz AG
BSTRINE
Page 1/4
Note: If remedy 2 is unsuccessful please open a PTSS case for processing.
Attachments
File
Description
remedy 2 motor location.jpg
Air recirculation flap actuator motor
remedy 2 motor removal.jpg
Air recirculation flap actuator motor removal
remedy 2 linkage orientation.jpg
Linkage orientation
Symptoms
Body / Air conditioning / Heater / Malfunction, air distribution
Control unit/fault code
Control unit
Fault code
Fault text
N22/1 - Air conditioning (AAC) B105C07
(HVAC177)
The actuator motor for the air recirculation flap has a malfunction.
There is a mechanical fault. (HVAC_F907)
N22/1 - Air conditioning (AAC) B113600
(HVAC177)
The measurement run for actuator motors for air flaps has a malfunction. _ (HVAC_F907)
Operation numbers/damage codes
Op. no.
Operation text
Time
54-0650
ON-BOARD POWER SUPPLY VOLTA- 0.1
GE MAINTAIN (WHEN CHECKING/TESTING AND TROUBLESHOOTING)
54-1011
PERFORM QUICKTEST
83-3117
PERFROM NORMALIZATION OF AC- 0.2
TUATOR MOTORS ON HEATING/VENTILATION/AC HOUSING
83-3139
FRESH AIR/RECIRCULATED AIR
FLAP ACTUATOR MOTOR REMOVE AND REINSTALL WITH LINKAGE
CORRECTION
Damage
code
Note
0.2
80460 73
0.2
Only claim when performing remedy
2
WIS-References
Document number
Title
Note
AR83.10-D-2041TS
Remove/install fresh air/recirculated air flap actuator
motor
Allocation
Remedy
Validity
Vehicle
Engine
Transmission
Sprinter 907
*
*
06-02-2020 3:27 PM
© Copyright Mercedes-Benz AG
BSTRINE
Page 2/4
Attachments
remedy 2 motor location.
jpg:
remedy 2 motor removal.
jpg:
06-02-2020 3:27 PM
© Copyright Mercedes-Benz AG
BSTRINE
Page 3/4
remedy 2 linkage orientation.jpg:
06-02-2020 3:27 PM
© Copyright Mercedes-Benz AG
BSTRINE
Page 4/4


© dot.report 2024

Use of this information constitutes acceptance for use in an AS IS condition. There are NO warranties, implied or otherwise, with regard to this information or its use. Any use of this information is at the user's risk. It is the responsibility of user to evaluate the accuracy, completeness or usefulness of any information, opinion, advice or other content. EACH USER WILL BE SOLELY RESPONSIBLE FOR ANY consequences of his or her direct or indirect use of this web site. ALL WARRANTIES OF ANY KIND ARE EXPRESSLY DISCLAIMED. This site will NOT BE LIABLE FOR ANY DIRECT, INDIRECT or any other kind of loss.