B2012-14

Service Bulletin Details

Public Details for: B2012-14

Ecm software update. (optional).


- 2012 - 2011 -

ROADSTER
SERVICE
Bulletin
January 23, 2014
Subject: ECM Software Update - optional
YEAR
2011
2012
2012-14
No.
MODEL
MODEL NUMBER
Spyder RT SM5 and SE5
All
This is an optional software update for vehicles
which already had WARRANTY BULLETIN 2012-8
OR 2012-10 done. It is not covered under warranty and could be performed during normal vehicle maintenance.
This software update includes improved diagnostics functions.
If the following icon appears when connecting the
vehicle to B.U.D.S., it means that an update is
available.
rmr2010-020-003_a
PARTS REQUIRED
The following B.U.D.S. version is required and
available on KNOWLEDGE CENTER :
5. Identify and download proper file.
Please note that you can also type in the keyword(s) field the B.U.D.S. single file number
directly without going in the "Advanced Search".
PROCEDURE
ECM Software Update
The following items must be carried out:
– Preparation
– ECM software update
– Update validation
– ECM initialization
– Clearing faults
Notes For The Module Updates
MODULE
APPROXIMATE
TIME FOR THE
REFLASH
ECM software update
4-6 minutes
For more detailed explanations on the content of
these updates, please refer to the BRP KNOWLEDGE CENTER. In the keyword(s) field, enter
either the article number OR the title between
quotes:
ARTICLE NUMBER
TITLE
52965
"Roadster December
2013 ECM update"
B.U.D.S. - R3.5.1 (or newer) for
Roadster - Single File
1. Click on "Advanced Search".
2. Select "Diagnostic Software".
3. In the keyword(s) field, type in the B.U.D.S.
single file number.
4. "SEARCH".
Printed in Canada. (rbs2012-014 en MS-SC)
©2014 Bombardier Recreational Products Inc. and BRP US Inc. All rights reserved.
®™ and the BRP logo are trademarks of Bombardier Recreational Products Inc. or its affiliates.
1/ 8
Preparation
NOTE: On SE5 models, the engine may need to
be started to set transmission to"N". When done,
stop engine.
4. RELEASE the parking brake.
5. Ensure trailer mode is deactivated (if applicable). Refer to OPERATOR'S GUIDE.
6. Ensure the vehicle battery is fully charged.
7. Connect a portable power pack (fully charged)
to the vehicle battery.
NOTE: Depending on vehicle model and year of
production, the portable power pack can be connected to the battery at one of the following three
locations.
Computer and Vehicle Preparation
NOTICE
Continuous power to the computer and to the
vehicle is mandatory during this operation or
damage to a module could occur.
Be sure to disable the computer screen saver.
If using a portable computer, be sure to provide
a continuous supply of electrical power by
connecting it to a wall outlet.
To ensure there is enough power to the vehicle
electronic modules to complete the software
updates, use a portable power pack.
NEVER use a battery charger instead of portable
power pack. The battery charger may cause
electrical noise causing problems during the
update.
These software updates of the vehicle modules
will take some time to complete and MUST NOT
be interrupted.
Although computer screen may blank or may
seem to freeze for a while, do NOT interrupt
B.U.D.S. to allow updates to be completed. Do
not touch the PC.
rbg2010-003-032
CONNECTION AT BATTERY POSTS UNDER SEAT
Although the cluster will blank, do NOT interrupt
B.U.D.S. to allow updates to be completed. Do
not touch the vehicle.
1. Place the vehicle on a level surface.
2. Install 4 wheel chocks (2 on each front wheel)
to prevent any movements of the vehicle during
the procedure.
rmo2013-003-032_a
CONNECTION AT JUMP START POSTS IN LH SERVICE CENTER,
UNDER FRONT STORAGE COMPARTMENT COVER
1. NEGATIVE (-) post
2. POSITIVE (+) post
rbg2010-004-001_a
WHEEL CHOCK INSTALLATION, EACH FRONT WHEEL
3. Set transmission to NEUTRAL.
2/ 8
2012-14
SERVICE
B.U.D.S. Connections
1. Connect MPI before starting B.U.D.S. to ensure
proper operation. Refer to the applicable SHOP
MANUAL for details:
– Section 03: ELECTRONIC MANAGEMENT
SYSTEMS
rbg2012-006-007
– Subsection 03: COMMUNICATION TOOLS
EXAMPLE
AND B.U.D.S.
MANDATORY TOOLS
A personal computer (laptop or desktop)
MPI-2 INTERFACE CARD
(P/N 529 036 018)
MODEL
NUMBER OF
MODULES
CONNECTED
RT SM5
6
RT SE5
7
NOTE: If a CAN Configuration Kit (CCK) is inMPI-2 DIAGNOSTIC CABLE
(P/N 710 000 851)
OPTIONAL TOOL
Extension cable
available at electronic retail outlets.
Do not exceed 7.5 m (25 ft)
stalled, the number of modules listed in B.U.D.S.
will be increased by one.
ECM Software Update
1. Click on Read Data.
2. Start B.U.D.S. and logon.
3. Turn ignition key ON.
vmr2006-012-100_aen
NOTE: If the following icon appears, an update is
available.
rmr2008-039-002
TYPICAL - IGNITION KEY ON
NOTE: If the following message does not auto-
matically go away, click the Retry button.
rmr2010-020-003_a
UPDATE AVAILABLE ICON
2. In the MODULE drop down menu, select ECM,
UPDATE.
smr2014-026-003_a
RETRY BUTTON
Compare number of modules shown in B.U.D.S.
with following table.
SERVICE
2012-14
3/ 8
rbg2009-005-109
TYPICAL - MODULE SUBMENU, ECM, UPDATE
rbg2013-011-112
3. Select the "File Name" 219 800 317.fc, then
click "OK".
rbg2013-011-114_a
5.1 Clicking "OK" will prompt you to the FAULT
screen.
5.2 Before proceeding with the update, fault
codes relating to a current customer complain should be repaired; all other fault
codes should be cleared.
ECM Software Update continued
FILE TO BE SELECTED
4. When the following message appears, click
"Yes" to start the update.
NOTICE While the ECM is being updated, an
hour glass will appear on the computer. The
computer screen and cluster might also go
blank. DO NOT TOUCH ANYTHING (PC and
vehicle) until the following message appears.
Then, click the "OK" button.
rbg2009-005-102
SUCCESSFUL ECM UPDATE CONFIRMATION - CLICK "OK"
rbg2013-011-115
6. When the following message appears, click
"Yes".
ECM UPDATE CONFIRMATION - CLICK "YES"
5. If the following message appears, then there is
"Active" or "Occurred" fault(s).
rbg2013-005-004
CLUSTER SECURITY MATCHING REQUEST - CLICK "YES"
7. When the following message appears:
7.1 Turn ignition key to OFF.
7.2 Wait until the message vanishes.
4/ 8
2012-14
SERVICE
rbg2014-001-002
NEW IMAGE
8. When the following message appears, turn ignition key to ON and wait until the message
vanishes.
rbg2013-005-005_a
9. The ECM software update is completed.
Update Validation
1. Click on Read Data button.
rbg2011-007-005_a
TYPICAL
1. BRP Assembly number
ECM INFORMATION
vmr2006-012-100_aen
READ DATA BUTTON
2. Check if the update has been successful.
BRP
assembly
number
MY 2011 - 2012
420666565
420666567
420666496
420666498
4. If any number in the table is found in B.U.D.S.,
then the update was successful.
5. If a wrong number is found, repeat the update
procedure.
ECM Initialization
IMPORTANT: Do not activate anything on the vehicle while performing a module reset.
ECM First Initialization
rbg2009-003-100
1. In B.U.D.S., click the items in the illustrated order.
MODULE, ECM, INFORMATION
3. Look at the "BRP Assembly Number", compare
with list in table.
SERVICE
2012-14
5/ 8
rbg2012-006-116
CLICK "OK"
5. When the following message appears:
5.1 Turn ignition key to OFF.
5.2 Wait until the message vanishes.
rbg2013-005-007_a
Step 1: Setting tab
Step 2: ECM tab
Step 3: Reset (ECM First Initialization)
2. When the following message appears:
2.1 Follow on screen instructions.
2.2 Click "OK".
rbg2014-001-002
NEW IMAGE
6. When the following message appears:
6.1 Turn ignition key to ON.
6.2 Wait until the message vanishes.
rbg2013-005-005_a
7. When the following message appears, click
"OK".
rbg2013-005-006_a
CLICK OK
3. When the following message appears:
3.1 Follow on screen instructions.
3.2 Click the "OK" button.
rbg2012-006-208
CLICK "OK"
rbg2012-006-115
4. When the following message appears, click the
"OK" button.
6/ 8
8. Ensure all the gear LEDs are OFF in B.U.D.S.
2012-14
SERVICE
3. Run transmission through all gears (N, R,
1-2-3-4-5 and back to N) waiting until its LED
turns green (in B.U.D.S.) before changing gear.
NOTE: On SM5 models, the clutch must be fully
released for each gear.
NOTICE Apply brake to stop wheel before
shifting from reverse to forward.
NOTE: Engine speed above 3000 RPM is required
to shift forward gears.
CAUTION Do not exceed 3800 RPM.
NOTE: During the GBPS learning procedure, the
cluster may show an orange screen and numerous indicator lights may come on (CHECK ENG,
VSS, ABS, LIMP HOME, etc).
rbg2013-005-007_b
GEAR POSITION SENSOR LEDS
1. All the gear LEDs OFF
GBPS Learning
1. Position a floor jack under the lower portion of
the rear shock absorber and lift the rear of vehicle until the rear wheel is off the ground.
NOTICE The floor jack must be positioned so
that it cups the lower portion of the rear shock
absorber.
rbg2013-005-007_c
GEAR POSITION SENSOR LEARNING LEDS
1. Wait until the gear LED turns green (learned) before shifting
4. All gear position sensor LEDs must be green in
B.U.D.S. to confirm the GBPS learning is completed.
rbg2010-004-002_a
1. Lower portion of shock absorber
WARNING
Before starting engine, ensure the rear tire
is well off the ground and cannot come into
contact with any obstacle (ground, jack stand,
etc.). Keep hands, tools, feet and clothing
clear of rotating parts (rear wheel assembly,
drive belt). Ensure no one is standing in
close proximity to the vehicle.
2. Start engine.
SERVICE
2012-14
7/ 8
rbg2010-003-033_b
CLEARING FAULTS
Step 1: Faults
Step 2: Click "Clear Occurred Faults" button
3. When the following message appears, click the
"Yes" button.
rbg2013-005-007_d
ALL GEARS LEARNED
1. All gear position sensor LEDs ON
5. Turn ignition key OFF.
6. Wait for the following message to appear.
rbg2013-005-005_a
rbg2012-006-119
7. Turn the ignition key ON and wait until the message vanishes.
Clearing Faults
1. In B.U.D.S., click on Read Data.
CONFIRM CLEAR FAULTS REQUEST - YES
NOTE: To clear all faults, it may be necessary turn
the ignition key OFF, wait a few seconds, turn the
ignition key back ON and activate the Clear Occurred Faults button once more.
4. Turn ignition key OFF.
5. When the following message appears, turn ignition key to ON, then click the "OK" button.
rbg2013-005-005_a
vmr2006-012-100_aen
READ DATA BUTTON
2. Click the items in the illustrated order.
6. Click on the Clear Occurred Faults button
again and ensure all faults are cleared.
7. Turn ignition key OFF.
NOTICE To avoid potential vehicle damage, it
is very important to turn ignition key off BEFORE exiting B.U.D.S. or unplugging the MPI-2
diagnostic cable from the vehicle.
8. Unplug MPI-2 diagnostic cable from vehicle.
9. Remove floor jack from under vehicle.
8/ 8
2012-14
SERVICE


© dot.report 2024

Use of this information constitutes acceptance for use in an AS IS condition. There are NO warranties, implied or otherwise, with regard to this information or its use. Any use of this information is at the user's risk. It is the responsibility of user to evaluate the accuracy, completeness or usefulness of any information, opinion, advice or other content. EACH USER WILL BE SOLELY RESPONSIBLE FOR ANY consequences of his or her direct or indirect use of this web site. ALL WARRANTIES OF ANY KIND ARE EXPRESSLY DISCLAIMED. This site will NOT BE LIABLE FOR ANY DIRECT, INDIRECT or any other kind of loss.