SB_628
Service Bulletin Details
Public Details for: SB_628
Proper application of ladder rung covers with adhesives to ensure binding to ladder rungs.
- 2022 - 2021 - 2020 - 2019 - 2018 - 2017 - 2016 - 2009 - 2008 - 2007 - 2006 - 2005 - 2004 - 2003 -
Models from 2022
2022 PIERCE LADDER AND PLATFORM |
Models from 2021
2021 PIERCE LADDER AND PLATFORM |
Models from 2020
2020 PIERCE LADDER AND PLATFORM |
Models from 2019
2019 PIERCE LADDER AND PLATFORM |
Models from 2018
2018 PIERCE LADDER AND PLATFORM |
Models from 2017
2017 PIERCE LADDER AND PLATFORM |
Models from 2016
2016 PIERCE LADDER AND PLATFORM |
Models from 2009
2009 PIERCE 75' ALUMINUM LADDER |
Models from 2008
2008 PIERCE 75' ALUMINUM LADDER |
Models from 2007
2007 PIERCE 75' ALUMINUM LADDER |
Models from 2006
2006 PIERCE 75' ALUMINUM LADDER |
Models from 2005
2005 PIERCE 75' ALUMINUM LADDER |
Models from 2004
2004 PIERCE 75' ALUMINUM LADDER |
Models from 2003
2003 PIERCE 75' ALUMINUM LADDER |
Title: Rung Cover Adhesive Number: SB_628 Release Date: 5/2/2023 Revision Number: Not Applicable Revision Date: Not Applicable Chassis Type: All Aerials Component Description: Not Applicable Warranty: Not Applicable Parts: SikaFlex®-252 Adhesive, Tools: Not Applicable Subject: Proper application of ladder rung covers with adhesives to ensure binding to ladder rungs. Purpose/Background: SikaFlex®-252 is an acceptable alternative for Bostik 70-03A Adhesive (P/N 95-3508) with Part B hardener (P/N 95-3507), applied with tip P/N 95-3510. Any appropriate delivery device (commonly referred to as a “caulk gun”) should work with SikaFlex®-252. Description/Procedure: 1. Use infrared thermometer gun to verify that the ladder rungs are between 41°F to 95°F (5°C to 35°C). NOTE: Adhesive will not bond correctly if ladder rungs are not between 41°F to 95°F (5°C to 35°C). Pa g e 1 o f 2 SERVICE BULLETIN #SB_628 2. Refer to ladder assembly drawing for run cover locations and addition installation information. 3. Load Sikaflex-252 (P/N 95-0772) into delivery device. 4. Place a ¼” (0.635 cm) wide bead of adhesive 1 ½” (3.81 cm) from each end of the ladder rung cover. 5. If ladder rung cover is 24” or more in length, then place an additional 2” (5.08 cm) of adhesive in the center of the ladder rung cover. 6. Use a rubber mallet or dead-blow hammer to ensure rung cover is installed tightly on the ladder rung. 7. Do not walk on ladder for 24 hours to allow adhesive to dry. If any additional support is needed, please open a technical support incident on Pierceparts.com. Pa g e 2 o f 2