SSM76080
Service Bulletin Details
Public Details for: SSM76080
Engine cooling fan excessive noise when plug in charger in use
Reference SSM76080 Models New Range Rover / L460 New Range Rover Sport / L461 Title Engine Cooling Fan Excessive Noise When Plug In Charger In Use Category Engine Last modified 18-Sep-2023 00:00:00 Symptom 402000 Cooling System Concerns Content Model / Model Year / Derivative Range Rover / 23MY onwards / PHEV only Range Rover Sport / 23MY onwards / PHEV only Situation: JLR have received customer reports that the engine cooling fan operation is excessively noisy in operation for an extended period of time when the vehicle is being charged using a low ouput plug in home charger. Cause: Heating Ventilation Air Conditioning (HVAC) software. Action: Follow the instruction(s) below. DIAGNOSTIC INSTRUCTION: 1. Connect the JLR approved diagnostic equipment and the JLR approved battery support unit. 2. Launch Diagnosis Device Agent, and log in. 3. Select ‘Browse all’. 4. Select ‘Diagnostics. 5. Within ‘Modules’ select ’Heating Ventilation Air Conditioning (HVAC) Control Module'. 6. Within ‘Module Programming’ select ‘HVAC Software - Update Module’. 7. Select ‘Run’. 8. Follow all on-screen instructions to complete the task. 9. Disconnect the JLR approved diagnostic equipment and the JLR approved battery support unit. (Ref 000365531) anBhdHRlcnM7MjAyMy0wOS0yOVQxNjozMTo1My43NDRaOzEzNi4yMjYuNzQuMTA1Ow==