Mci D45 Crt Le 2018

Vehicle Details: Recalls, Service Bulletins

Below you will find all available information on the 2018 MCI D45 Crt Le.

ManufacturerKnown WMI(s)Fuel Type
MCI
MCI VIN Decoder

Use the box here to look up VINs from MCI as well as other manufacturers

#
Frequently Asked Questions
  • Are there recalls for the 2018 MCI D45 Crt Le?
     - There are 6 recall(s) for the 2018 MCI D45 Crt Le, additional information is below.
NHTSA Mandated Recalls
  • Recall 212909 [USA]: Mdp circuit board failure can result in a fire or an unexpected vehicle shutdown, increasing the risk of a crash.

  • Recall 206533 [USA]: A fuel leak in the presence of an ignition source increases the risk of a fire.

  • Recall 214310 [USA]: The power cables may chafe, increasing the risk of a fire.

  • Recall 147004 [USA]: If the engine shuts down or loses power while the vehicle is in motion, this may increase the risk of a crash.

  • Recall 2021297 [Canada]: Fuel supply

  • Recall 2020276 [Canada]: Electrical

To ensure accuracy and for your safety, it is recommended to do a free VIN recall check here or here [USA] - UK - Canada.

Bulletins

Bulletins are notices put out by manufacturers in conjunction with the NHTSA to notify the public of manufacturing issues or changes.

  • TSIB 22-12 - ELECTRICAL SYSTEM: Mci has released technical service information bulletin (tsib) 22-12 to address concerns with water ingress in remote switch box. The tsib provides guidance on how to rework the box to inhibit water intrusion and connector corrosion
  • TSIB 22-03 - SEATS: Technical service information bulletin describing the replacement of seating backrest attachment hardware with the addition of a mechanical lock nut on specifically equipped buses manufactured prior to model year 2020.
  • ITS60421 - ELECTRICAL SYSTEM: This technical instruction is a description of the inspections and cleaning procedures being recommended by mci due to the parts shortages which are impacting the repair inspections associated with nhtsa recall 21v-748. These are the same i
  • ITS60421 - ELECTRICAL SYSTEM: This instruction to service (its) is a description of the inspections being recommedned by mci due to the parts shortages which are impacting the repair instructions associated with nhtsa recall 21v-748. These are the same instructions as o
  • TSIB 22-01 - ELECTRICAL SYSTEM: This is an upgrade to technical service information bulletin tsib 21-10 issued in january of 2022 which is specific to buses operating in severe duty and or corrosive environments. These bulletins have been issued to recommend interim inspe
  • TSIB 21-10 - ELECTRICAL SYSTEM: This technical service information bulletin describes interim inspection procedures required every 6000 miles on specific motor coaches due to the global parts shortage and subsequent delay in available parts to conduct the corrective actio
  • TSIB 21-01 - SERVICE BRAKES, HYDRAULIC: This technical service information bulletin (tsib) describes an update from meritor for the bolt torque application requirements on hub-to-rotor bolts for the front, drive and tag axles, on specific coaches equipped with meritor ex225 disc
  • SB 3145 - EQUIPMENT: This service bulletin informs affected owners of the steps to remove the unused saucon provisional connector, mci p/n 19-11-2941, located in the front junction box on coaches without a saucon telematics module.
  • FCP 478 - SERVICE BRAKES, AIR: This service bulletin advises owners of affected vehicles that zf has notified mci that some brake chambers installed on the zf drive axle have had water ingress, causing malfunction of the pneumatic brake system and dragging brakes during
  • FCP 475 - VEHICLE SPEED CONTROL: This service bulletin advises owners of affected vehicles that the throttle pedal sensors may provide intermittent, erratic data and cause the "engine check" light to become illuminated, and how repairs can be made to correct the vehicles.
  • P03-263 - STRUCTURE: This procedure outlines the steps to replace the aluminum rivets with stainless steel nuts and bolts to secure the rad panel due to galvanic corrosion.

© dot.report 2024

Use of this information constitutes acceptance for use in an AS IS condition. There are NO warranties, implied or otherwise, with regard to this information or its use. Any use of this information is at the user's risk. It is the responsibility of user to evaluate the accuracy, completeness or usefulness of any information, opinion, advice or other content. EACH USER WILL BE SOLELY RESPONSIBLE FOR ANY consequences of his or her direct or indirect use of this web site. ALL WARRANTIES OF ANY KIND ARE EXPRESSLY DISCLAIMED. This site will NOT BE LIABLE FOR ANY DIRECT, INDIRECT or any other kind of loss.