519-14
Service Bulletin Details
Public Details for: 519-14
519-14 fmi 1: scr nox conversion efficiency very low
- 2015 - 2014 - 2013 - 2012 - 2011 - 2010 -
Models from 2015
Models from 2014
Models from 2013
Models from 2012
Models from 2011
Models from 2010
5 19-14 1 5 19-14 SUBJECT DATE SPN 4364 (ACM) (GHG14) May 2014 Additions, Revisions, or Updates Publication Number / Title DDC-SVC-MAN-0084 Platform Section Title Change GHG14 DD Platform SPN 4364/FMI 1 GHG14 Change entire procedure to refer to diagnostics for SPN 4364/FMI 18- GHG14 All information subject to change without notice. 5 19-14 Copyright © 2014 DETROIT DIESEL CORPORATION 3 2 SPN 4364/FMI 1 – GHG14 2 SPN 4364/FMI 1 – GHG14 SCR NOx Conversion Efficiency Very Low Table 1. SPN 4364/FMI 1 Description SCR NOx Conversion Efficiency Very Low Monitored Parameter SCR NOx Conversion Efficiency Typical Enabling Conditions DEF Dosing Valve On, 1000 to 1500 rpm, 15 to 100% load Monitor Sequence None Execution Frequency Continuous when enabling conditions met Typical Duration 30 Minutes Dash Lamps MIL Engine Reaction Derate 25% Verification Parked Regen Check as follows: 1. Refer to the diagnostic procedure for SPN 4364/FMI 18-GHG14. 4 All information subject to change without notice. Copyright © 2014 DETROIT DIESEL CORPORATION 5 19-14