519-14 fmi 1: scr nox conversion efficiency very low


- 2015 - 2014 - 2013 - 2012 - 2011 - 2010 -

5 19-14
1
5 19-14
SUBJECT
DATE
SPN 4364 (ACM) (GHG14)
May 2014
Additions, Revisions, or Updates
Publication Number / Title
DDC-SVC-MAN-0084
Platform
Section Title
Change
GHG14 DD
Platform
SPN 4364/FMI 1 GHG14
Change entire procedure to refer to diagnostics for SPN 4364/FMI
18- GHG14
All information subject to change without notice.
5 19-14
Copyright © 2014 DETROIT DIESEL CORPORATION
3
2 SPN 4364/FMI 1 – GHG14
2
SPN 4364/FMI 1 – GHG14
SCR NOx Conversion Efficiency Very Low
Table 1.
SPN 4364/FMI 1
Description
SCR NOx Conversion Efficiency Very Low
Monitored Parameter
SCR NOx Conversion Efficiency
Typical Enabling Conditions
DEF Dosing Valve On, 1000 to 1500 rpm, 15 to 100% load
Monitor Sequence
None
Execution Frequency
Continuous when enabling conditions met
Typical Duration
30 Minutes
Dash Lamps
MIL
Engine Reaction
Derate 25%
Verification
Parked Regen
Check as follows:
1. Refer to the diagnostic procedure for SPN 4364/FMI 18-GHG14.
4
All information subject to change without notice.
Copyright © 2014 DETROIT DIESEL CORPORATION 5 19-14


© dot.report 2024

Use of this information constitutes acceptance for use in an AS IS condition. There are NO warranties, implied or otherwise, with regard to this information or its use. Any use of this information is at the user's risk. It is the responsibility of user to evaluate the accuracy, completeness or usefulness of any information, opinion, advice or other content. EACH USER WILL BE SOLELY RESPONSIBLE FOR ANY consequences of his or her direct or indirect use of this web site. ALL WARRANTIES OF ANY KIND ARE EXPRESSLY DISCLAIMED. This site will NOT BE LIABLE FOR ANY DIRECT, INDIRECT or any other kind of loss.