Tsb: revision notice august 23, 2017 rev1: ? Applicability has been updated to include 2015 model year xb vehicles, 2015 ? 2016 model year tc vehicles, and 2016 model year im vehicles. ? The parts information section has been updated. Any p
- 2016 - 2015 - 2014 - 2013 - 2012 - 2011 - 2010 - 2009 - 2008 -
Models from 2016
2016 SCION IM |
2016 SCION TC |
Models from 2015
2015 SCION TC |
2015 SCION XB |
Models from 2014
2014 SCION TC |
2014 SCION XB |
2014 SCION XD |
Models from 2013
2013 SCION TC |
2013 SCION XB |
2013 SCION XD |
Models from 2012
2012 SCION TC |
2012 SCION XB |
2012 SCION XD |
Models from 2011
2011 SCION TC |
2011 SCION XB |
2011 SCION XD |
Models from 2010
2010 SCION XB |
2010 SCION XD |
Models from 2009
2009 SCION XB |
2009 SCION XD |
Models from 2008
2008 SCION XB |
2008 SCION XD |
S-SB-0012-14 Rev1 April 29, 2014 HVAC Evaporator Drain Hose Clogged Due to Insect Intrusion Service Category Vehicle Interior Section Heating/Air Conditioning USA Market Applicability YEAR(S) MODEL(S) 2016 iM 2011 – 2016 tC 2008 – 2015 xB 2008 – 2014 xD ADDITIONAL INFORMATION REVISION NOTICE August 23, 2017 Rev1: • Applicability has been updated to include 2015 model year xB vehicles, 2015 – 2016 model year tC vehicles, and 2016 model year iM vehicles. • The Parts Information section has been updated. Any previous printed versions of this bulletin should be discarded. Introduction Some vehicles in particular geographic areas may exhibit a condition where the HVAC Evaporator Drain Hose has become obstructed with an insect nest. An insect repellent drain hose tip (ARINIX® Tip) is now available to help minimize future occurrences of this environmental condition. For some models, a new drain hose is required to properly fit the ARINIX® Tip. Follow the procedures in this bulletin for proper handling and installation of this optional service part. NOTE The ARINIX® Tip is NOT registered or labeled for sale or use outside the United States or Puerto Rico. Warranty Information OP CODE DESCRIPTION TIME OFP T1 T2 N/A Not Applicable to Warranty – – – – © 2017 Toyota Motor Sales, USA Page 1 of 5 S-SB-0012-14 Rev1 April 29, 2014 Page 2 of 5 HVAC Evaporator Drain Hose Clogged Due to Insect Intrusion Parts Information PART NUMBER MODEL MODEL YEAR 2008 – 2016 2011 – 2013 87265-33010 88539-12200 tC Late 2013 – 2016 xB xD iM 2008 – 2013 QTY Connector, Water Hose (ARINIX® Tip) All 1 88539-12230 Hose, Drain Cooler 90480-26030 Grommet 88539-21030 88539-12200 REPAIR PROCEDURE NEW PREVIOUS All PART NAME A B Hose, Drain Cooler 88539-12230 90480-26030 2015 88539-12230 2008 – 2010 88539-52020 2011 – 2014 88539-52040 2016 88539-12230 A Grommet 1 1 1 1 1 1 Hose, Drain Cooler B 1 1 1 Required Tools & Equipment REQUIRED MATERIAL QUANTITY Chemical Resistant Gloves (Made From Waterproof Material) 1 Safety Requirements for Handling the ARINIX® Tip (Water Hose Connector) • Follow the manufacturer’s instructions for cleaning/maintaining Personal Protection Equipment (PPE). If no such instructions for cleaning/maintaining PPE exist, use detergent and hot water. Keep PPE separate from other laundry. • Users should remove PPE immediately after handling this product. • Wash the outside of the gloves before removing. • Users should wash hands before eating, drinking, chewing gum, or using the toilet. © 2017 Toyota Motor Sales, USA S-SB-0012-14 Rev1 April 29, 2014 Page 3 of 5 HVAC Evaporator Drain Hose Clogged Due to Insect Intrusion Safety Requirements for Handling the ARINIX® Tip (Water Hose Connector) (Continued) CAUTION IF SWALLOWED: Call a poison control center or doctor immediately for treatment advice. Have the person sip a glass of water if able to swallow. • Do NOT induce vomiting unless instructed by a poison control center or doctor. • Do NOT give anything by mouth to an unconscious person. IF ON SKIN OR CLOTHING: Take off the contaminated clothing immediately. Rinse skin immediately with plenty of water for 15 to 20 minutes. Call a poison control center or doctor for treatment advice. IF IN EYES: Hold eye(s) open and rinse gently and slowly with water for 15 to 20 minutes. Remove contact lenses (if present) AFTER the first 5 minutes, then continue rinsing eye(s). Call a poison control center or doctor for treatment advice. HOTLINE NUMBER: Have the product container or label with you when calling a poison control center or doctor or when going for treatment. You may also contact 1-800-424-9300 for emergency medical treatment information. © 2017 Toyota Motor Sales, USA Rev1 S-SB-0012-14 April 29, 2014 Page 4 of 5 HVAC Evaporator Drain Hose Clogged Due to Insect Intrusion Directions for Use on ALL Repair Procedures The ARINIX® Tip contains permethrin, a pesticide, as the active ingredient. Note, it is a violation of Federal law to use this product in a manner inconsistent with its labeling. Repair Procedure A 1. Follow the instructions provided in the Safety Requirements for Handling the ARINIX® Tip (Water Hose Connector) section of this bulletin. 2. Locate the HVAC evaporator drain hose. 3. Refer to the Technical Information System (TIS), applicable model and model year Repair Manual to remove the HVAC evaporator drain hose. 4. Put on necessary PPE and install the ARINIX® Tip (Water Hose Connector) into the NEW HVAC evaporator drain hose listed in the Parts Information section of this bulletin. 5. When installing the ARINIX® Tip, verify that it is fully seated in the HVAC evaporator drain hose as shown. Figure 1.. 6. Refer to TIS, applicable model and model year Repair Manual to install the HVAC evaporator drain hose. © 2017 Toyota Motor Sales, USA S-SB-0012-14 Rev1 April 29, 2014 Page 5 of 5 HVAC Evaporator Drain Hose Clogged Due to Insect Intrusion Repair Procedure B 1. Follow the instructions provided in the Safety Requirements for Handling the ARINIX® Tip (Water Hose Connector) section of this bulletin. 2. Locate the HVAC evaporator drain hose. 3. Refer to TIS, applicable model and model year Repair Manual to remove the HVAC evaporator drain hose. 4. Put on ALL necessary PPE and install the ARINIX® Tip into the ORIGINAL HVAC evaporator drain hose listed in the Parts Information section of this bulletin. 5. When installing the ARINIX® Tip, verify that it is fully seated in the HVAC evaporator drain hose as shown in Figure 1. 6. Refer to TIS, applicable model and model year Repair Manual to install the HVAC evaporator drain hose. © 2017 Toyota Motor Sales, USA