Altec has learned that certain rear-mounted lr7 units built from may 2019 to april 2021 have reports of the platform ribs separating from the platform shell near the bottom of the platform. The separation can be caused by excessive bouncing


- 2021 - 2020 -

Altec Industries, Inc.
Creedmoor Operations
Creedmoor, NC
SIL 806
Service Information Letter
June 28, 2021
Units Affected: Rear-mounted LR7 units built from May 2019 to April 2021 (Verify your unit serial number is affected by reviewing the attached list in this SIL or by accessing your fleet on connect.altec.com/
login)
Platform Ribs Inspection
Altec is committed to providing our customers safe and reliable products from initial delivery throughout
the useful life of the unit.
Altec has learned that the affected units have reports of the platform ribs separating from the platform shell
near the bottom of the platform. The separation can be caused by excessive bouncing from road vibration
if the upper boom is not properly secured.
Altec recommends the platform be inspected using the procedure beginning on page 2.
A repair kit, part number 991298748, can be ordered by calling Altec at 1-877-GO ALTEC (1-877-4625832), option 1.
If the platform does not require repair, complete the Inspection Sheet at the end of this document.
The inspection and repair are covered under the Altec Warranty Policy and can be performed by Altec, the
customer, or the customer’s warranty provider. Altec will perform the work for free at an Altec facility. If
the customer or the customer’s warranty provider performs the work, a warranty claim must be submitted
to be reimbursed for the cost of the parts and/or labor. Altec will allow up to $22.50 for the labor to perform the inspection and up to $135 for labor to perform the repair. Call 1-877-GO ALTEC (1-877-4625832) to schedule the work to be done by an Altec service technician. Customers are responsible for the
travel costs of an Altec Mobile Service technician if the technician performs the inspection and repair at
the owner’s location.
Inspection labor
Repair labor
Account #
Travel
NHTSA code
Prime fail P/N
Doc ref
Altec Use Only
0.25 hr
1.5 hr
010.1026.43151.455.0000.000
Not included
98
990577019; 990439893
074900775
Altec Use Only
Kit Description
Part No.
SIL 806 - modular platform repair kit
991298748
Page 1 of 3
Qty
1
Warranty
Yes
SIL 806
Inspection Procedure
1. Position the unit on a level surface. Apply the parking brake and chock the wheels.
2. Decide which platform position will be used for inspection of the platform ribs.
• If the ribs will be inspected with the boom stowed, disengage the PTO and turn off the
engine. Remove the key from the ignition and secure it. Follow your employer’s vehicle
lockout/tagout procedure.
• If ribs will be inspected from the ground, properly set the outriggers. Unstow the booms
and articulate them to position the platform near the ground. Disengage the PTO and turn
off the engine. Remove the key from the ignition and secure it. Follow your employer’s
vehicle lockout/tagout procedure.
3. Visually inspect the platform ribs where they attach to the outside of the platform shell near
the bottom of the platform without removing the outer controls cover (refer to Figure 1). Inspect the outboard side and inboard side edges of both ribs for separation cracks between the
rib structure and the platform shell (refer to Figure 2).
• If there are no cracks, complete the Inspection Sheet at the end of this document to record
completion.
• If separation cracks are present in the lower portion of the platform rib (below the rib
reinforcement), do the following.
• Order repair kit, part number 991298748, by calling Altec at 1-877-GO ALTEC (1-877462-5832), option 1. Do not complete the Inspection Sheet at the end of this document.
• The unit can remain in service.
• If separation or damage is present above the rib reinforcement or elsewhere on the platform, contact Altec Technical Support at 1-877-GO ALTEC (1-877-462-5832), option 4.
Remove the unit from service. Do not complete the Inspection Sheet at the end of this
document.
Platform Shell
Outer Controls
Cover
Rib Reinforcement
Separation
Crack
Rib 1
Rib 2
Figure 1 — Platform
Figure 2 — Separation Crack
4. If the booms were unstowed, stow the booms and retract the outriggers.
Page 2 of 3
SIL 806
SIL 806 Platform Ribs Inspection Sheet
Complete this form and return to Altec to document completion.
Choose one of these options.
• Online through the customer portal – Altec Connect*
		 Sign in or Register for an account at www.altec.com/altec-connect/
		 1. Select Equipment
		 2. Select Altec Product Notices
		 3. Select Report a Completed APN
• Scan and Email to [email protected]
• FAX to 1-877-659-9929
*Customer performed warranty can be submitted online for reimbursement
through Altec Connect.
Model
Altec Unit Serial Number
To login to your existing
Altec Connect account,
scan here with your
smart phone!
Date Inspected
Company Name: _______________________________________________
Phone____________________________
Service Company Name:_________________________________________
Phone:___________________________
Company Contact: _________________________________________________________________________________
Company Street Address:_____________________________________________________________________________
City _______________________________________________ State:_________________ ZIP Code:________________
Signature:_____________________________________________________
Submission of this form does not order parts or schedule service from Altec.
If the customer or the customer’s warranty provider performs the repair, a warranty claim must
be submitted to be reimbursed for the cost of the parts and/or labor through Altec Connect.
For more information or to schedule the work to be done by an Altec Service technician, call:
1-877-GO ALTEC (1-877-462-5832)
Make copies of this form for additional units if needed.
Page 3 of 3


© dot.report 2024

Use of this information constitutes acceptance for use in an AS IS condition. There are NO warranties, implied or otherwise, with regard to this information or its use. Any use of this information is at the user's risk. It is the responsibility of user to evaluate the accuracy, completeness or usefulness of any information, opinion, advice or other content. EACH USER WILL BE SOLELY RESPONSIBLE FOR ANY consequences of his or her direct or indirect use of this web site. ALL WARRANTIES OF ANY KIND ARE EXPRESSLY DISCLAIMED. This site will NOT BE LIABLE FOR ANY DIRECT, INDIRECT or any other kind of loss.