KC-321
Service Bulletin Details
Public Details for: KC-321
Cummins powerplant - fault code spn 1081 fmi 31 - engine wait to start lamp, condition exists - model year 2018
- 2018 -
Models from 2018
2018 VOLVO VAH |
2018 VOLVO VHD |
2018 VOLVO VN |
2018 VOLVO VNL |
2018 VOLVO VNM |
2018 VOLVO VNR |
2018 VOLVO VNX |
1/31/22, 10:07 AM Article Cummins Powerplant - Fault Code SPN 1081 FMI 31 - Engine Wait to Start Lamp, Condition Exists - Model Year 2018 Internal Content If the symptoms described above are encountered on a Cummins-powered vehicle: 1. In Premium Tech Tool (PTT) under the Program tab, run Operation 1700-22-03-06 Accessory Kit. 2. In the Accessory Kit number entry field, enter 85154873. 3. Click Program. 4. Allow the operation to complete and click Exit. 5. Program the Instrument Cluster (MID 140). 6. Verify that the fault code is no longer set at startup. If the issue persists following programming: Open an eService case. The case must include: • A description of the issue, this fault code, and any other relevant information, especially any other symptoms that may be present. • A description of work performed. • A complete, current DTC Readout. • This solution number. ; Live UITags k04404042 1081 f i 31 it t t t k https://volvo-trkna-prod1.pegacloud.net/prweb/PRAuth/app/VolvoKM_/iNPUIKpeinqPJi2G0hH930k43USdE1gb*/!TABTHREAD2?pyActivity=%40basec… 1/2 1/31/22, 10:07 AM k04404042 Article spn 1081 fmi 31 wait to start mack volvo Related links and attachments No links or attachments available Feedback Give feedback to help improve the content of this article ; Live UI https://volvo-trkna-prod1.pegacloud.net/prweb/PRAuth/app/VolvoKM_/iNPUIKpeinqPJi2G0hH930k43USdE1gb*/!TABTHREAD2?pyActivity=%40basec… 2/2