SSM63597

Service Bulletin Details

Public Details for: SSM63597

Diagnostic concerns.


- 9999 - 2022 - 2021 - 2020 - 2019 - 2018 - 2017 - 2016 - 2015 - 2014 - 2013 - 2012 - 2011 - 2010 - 2009 - 2008 - 2007 - 2006 - 2005 - 2004 - 2003 - 2002 - 2001 - 2000 - 1999 - 1998 - 1997 - 1996 - 1995 - 1994 - 1993 - 1992 - 1991 - 1990 - 1989 - 1988 - 1987 - 1986 - 1985 - 1984 - 1983 - 1982 -

Models from 2022
2022 JAGUAR XJ
Models from 2021
2021 JAGUAR XJ
Models from 2019
2019 JAGUAR XJ
Models from 2018
2018 JAGUAR XJ
Models from 1996
1996 JAGUAR XJ
Models from 1995
1995 JAGUAR XJ
Models from 1994
1994 JAGUAR XJ
Models from 1993
1993 JAGUAR XJ
Models from 1992
1992 JAGUAR XJ
Models from 1991
1991 JAGUAR XJ
Models from 1990
1990 JAGUAR XJ
Models from 1989
1989 JAGUAR XJ
Models from 1988
1988 JAGUAR XJ
Models from 1987
1987 JAGUAR XJ
Models from 1986
1986 JAGUAR XJ
Models from 1985
1985 JAGUAR XJ
Models from 1984
1984 JAGUAR XJ
Models from 1983
1983 JAGUAR XJ
Models from 1982
1982 JAGUAR XJ
TOPIx - SSM63597 - Unable to communicate with PCM on Legacy Jaguar vehicles using... Page 1 of 1
Reference
SSM63597
Models
X-TYPE / X400
XK / X100
S-TYPE / X200
XJ V8 / X308
Title
Unable to communicate with PCM on Legacy Jaguar vehicles using DVD133
Category
Diagnostic Software Hardware
Last modified
28-Mar-2014 00:00:00
Symptom
000101 Diagnostic Concerns
Content
Issue:
Jaguar Land Rover North America Service Diagnostics would like to make all SDD users aware of an emerging concern being tracked
via the EPQR system.
Users report DVD133 is unable to fully communicate with PCM on legacy Jaguar vehicles, and regardless of PCM status Icon displayed
on network summary screen, SDD may not display DTC’s from the PCM
Cause:
This issue is currently under investigation in the UK and will be addressed on a future SDD software update.
Solution:
Users have confirmed the following workaround is effective for reading DTCs from PCM on Legacy Jaguar vehicles using DVD133.
After the initial data collection has been completed, simply repeat a full data collect function using the “twisted arrows” icon at the left side
of the VSOH/Network summary view on SDD.
Once the root cause has been identified and corrected, this SSM will be updated with DVD version/update the solution was delivered on.
Until then, please follow this workaround and raise an EPQR for circumstances that cannot be resolved using this interim advice.
http://topix.jaguar.jlrint.com/topix/service/archive/479282/index
6/3/2014


© dot.report 2024

Use of this information constitutes acceptance for use in an AS IS condition. There are NO warranties, implied or otherwise, with regard to this information or its use. Any use of this information is at the user's risk. It is the responsibility of user to evaluate the accuracy, completeness or usefulness of any information, opinion, advice or other content. EACH USER WILL BE SOLELY RESPONSIBLE FOR ANY consequences of his or her direct or indirect use of this web site. ALL WARRANTIES OF ANY KIND ARE EXPRESSLY DISCLAIMED. This site will NOT BE LIABLE FOR ANY DIRECT, INDIRECT or any other kind of loss.