08-042-14

Service Bulletin Details

Public Details for: 08-042-14

Flash: dead battery this bulletin involves updating the fold and stow module (fsm) with new software because the fsm stays awake resulting in a continuous electrical draw. The customer may experience a dead battery.


- 2014 - 2013 - 2012 - 2011 - 2010 - 2009 - 2008 -

Models from 2014
2014 DODGE CARAVAN
Models from 2013
2013 DODGE CARAVAN
Models from 2012
2012 DODGE CARAVAN
Models from 2011
2011 DODGE CARAVAN
Models from 2010
2010 DODGE CARAVAN
Models from 2009
2009 DODGE CARAVAN
Models from 2008
2008 DODGE CARAVAN
NUMBER:
GROUP:
DATE:
08-042-14
Electrical
April 23, 2014
This bulletin is supplied as technical information only and is not an authorization for repair. No part of this publication may be reproduced, stored in a retrieval system,
or transmitted, in any form or by any means, electronic, mechanical, photocopying, or otherwise, without written permission of Chrysler Group LLC.
HELP USING THE wiTECH DIAGNOSTIC APPLICATION FOR FLASHING AN ECU IS
AVAILABLE BY SELECTING “HELP” THEN “HELP CONTENTS” AT THE TOP OF
THE wiTECH DIAGNOSTIC APPLICATION WINDOW.
THE wiTECH SOFTWARE LEVEL MUST BE AT RELEASE 14.03 OR HIGHER TO
PERFORM THIS PROCEDURE.
SUBJECT:
Flash: Dead Battery
OVERVIEW:
This Bulletin involves updating the Fold and Stow Module (FSM) with new software
because the FSM stays awake resulting in a continuous electrical draw.
MODELS:
2008 - 2014
(RT)
Caravan, Voyager, Grand Voyager, Town
And Country
NOTE: This bulletin applies to vehicles built on or before March 18, 2014 (MDH
0318XX) equipped with Power Folding 3rd Row Seat (sales code JRJ).
SYMPTOM/CONDITION:
The customer may experience a dead battery.
DIAGNOSIS:
Using a Scan Tool (wiTECH) with the appropriate Diagnostic Procedures available in
TechCONNECT, verify no DTC's are set. If DTCs are present record them on the repair
order and repair as necessary before proceeding further with this bulletin.
If the customer describes the symptom/condition, perform the Repair Procedure.
REPAIR PROCEDURE:
NOTE: Install a battery charger to ensure battery voltage does not drop below 13.2
volts. Do not allow the charging voltage to climb above 13.5 volts during the
flash process.
NOTE: If this flash process is interrupted/aborted, the flash should be restarted.
08-042-14
-2-
1. Reprogram the FSM with the latest software. Help using the wiTECH diagnostic
application for flashing an FSM is available by selecting “help” then “help contents” at
the top of the wiTECH diagnostic application window.
2. Clear any DTC's that may have been set in all modules due to reprogramming. The
wiTECH application will automatically present all DTCs after the flash and allow the
tech to clear them.
POLICY:
Reimbursable within the provisions of the warranty.
TIME ALLOWANCE:
Labor Operation
No:
18-52-29-90
Description
Module, Fold and Stow Module (FSM), 6 - Electrical
Reprogram. (1 - Semi-Skilled)
and Body
Systems
FAILURE CODE:
FM
Skill Category
Flash Module
Amount
0.2 Hrs.


© dot.report 2024

Use of this information constitutes acceptance for use in an AS IS condition. There are NO warranties, implied or otherwise, with regard to this information or its use. Any use of this information is at the user's risk. It is the responsibility of user to evaluate the accuracy, completeness or usefulness of any information, opinion, advice or other content. EACH USER WILL BE SOLELY RESPONSIBLE FOR ANY consequences of his or her direct or indirect use of this web site. ALL WARRANTIES OF ANY KIND ARE EXPRESSLY DISCLAIMED. This site will NOT BE LIABLE FOR ANY DIRECT, INDIRECT or any other kind of loss.