Gillig Low Floor 2003

Vehicle Details: Recalls, Investigations, Consumer Complaints, Decoded VIN Details, Service Bulletins

Below you will find all available information on the 2003 GILLIG Low Floor, manufacturered by Gillig Llc.
The vehicle is described as a Transit Bus (City Bus).

ManufacturerKnown WMI(s)Fuel Type
GILLIG15G 46G
GILLIG VIN Decoder

Use the box here to look up VINs from GILLIG as well as other manufacturers

#

Sub-models: - Low Floor Bus -

Frequently Asked Questions
  • Where is the 2003 GILLIG Low Floor produced?
     - The 2003 GILLIG Low Floor is produced in Hayward California, United States (usa).
  • Are there recalls for the 2003 GILLIG Low Floor?
     - There are 9 recall(s) for the 2003 GILLIG Low Floor, additional information is below.
  • What is the GVWR of a 2003 GILLIG Low Floor?
     - The 2003 GILLIG Low Floor has a GVWR of Class 7: 26,001 - 33,000 lb (11,794 - 14,969 kg) lbs.
NHTSA Mandated Recalls
  • Recall 127711 [USA]: The reduced visibility of the turn signals can increase the risk of a crash.

  • Recall 152782 [USA]: The reduced visibility of the turn signals may increase the risk of a crash.

  • Recall 67708 [USA]: A short could occur, possibly causing smoke and fire.

  • Recall 37038 [USA]: Failure of the line introduces high pressure fuel spray into the engine compartment which can ignite when it comes in contact with a hot surface.

  • Recall 61120 [USA]: Engine malfunction could possible lead to engine and vehicle damage and potential for a vehicle fire.

  • Recall 34540 [USA]: In the event of a vehicle crash, the wheelchair may not be adequately secured possibly resulting in injuries.

  • Recall 56472 [USA]: Oil leakage on a hot engine can result in an engine compartment fire, possibly resulting in injuries.

  • Recall 56485 [USA]: This can result in a fire in the engine compartment.

  • Recall 56391 [USA]: Embrittlement could potentially lead to a transducer diaphragm failure.

To ensure accuracy and for your safety, it is recommended to do a free VIN recall check here or here [USA] - UK - Canada.

Bulletins

Bulletins are notices put out by manufacturers in conjunction with the NHTSA to notify the public of manufacturing issues or changes.

  • FS-2019-02 - ENGINE AND ENGINE COOLING:COOLING SYSTEM:HOSES/LINES/PIPING/FITTINGS: Because of a supply issue with the blue hose covering, eaton is temporarily making fc-300 hose using black covering. Fc-300 hose assemblies made between october 2018 to may 2019 will be affected by this change.
  • FS-2018-02 - STEERING: A procedure to properly adjust the draglink so the socket won't over articulate, causing increased wear.
  • FS-2018-01 - STEERING: It was found that an earlier bulletin spec'd bolts that could be too long due to variances in bolt shoulder length, so this bulletin was written to make sure bolt attachments were correct.
  • FS-2016-06 - STEERING: Gillig has received reports of partial cracking in the steering gear mounting plate in some low floor buses. We are now requesting that owners of all low floor buses from model year 1997 through june, 2015 inspect the steering gear mounting
  • FS-2016-06 - STEERING:GEAR BOX (OTHER THAN RACK AND PINION): Gillig has received reports of partial cracking in the steering gear mounting plate in some low floor buses. We are now requesting that owners of all low floor buses from model year 1997 through june, 2015 inspect the steering gear mounting
  • FS-2016-05 - EQUIPMENT: This field service bulletin provides new information from borg warner (delco) revising the maintenance procedure for starter b+ cable maintenance and torque values.
  • FS-2016-02 - EQUIPMENT:APPLIANCE:AIR CONDITIONER: This field service bulletin applies to all non-hybrid low floor buses with 480 volt hvac systems. It advises installation of a lockout mechanism for the battery disconnect system. Details are provided on how to obtain a lockout padlock from
  • FS-2016-01 - EQUIPMENT: This field service bulletin applies to all low floor buses with skf air dryers. It warns against the use of non-skf cartridges in skf air dryers and recommends only using genuine skf cartridges.
  • FS-2015-02 - EQUIPMENT:OTHER:OWNERS/SERVICE/OTHER MANUAL : This field service bulletin applies to all low floor buses. It advises on the necessity of maintaining proper ride height and provides current inspection and adjustment procedures.
  • FS-2014-02 - ENGINE AND ENGINE COOLING:COOLING SYSTEM:HOSES/LINES/PIPING/FITTINGS: This field service bulletin applies to all low floor buses with aeroquip fc-300 coolant hoses. Eaton aeroquip has recently determined that newer coolants containing oat (organic acid technology) are not compatible with their fc300 hose mate
  • FS-2014-01 - ELECTRICAL SYSTEM: This field service bulletin applies to all low floor buses with luminator or twin vision destination signs. It alerts owners of an operational warning issued by the supplier against utilizing the usb port on their destination sign to charge
  • FS-2013-02 - AIR BAGS: This field service bulletin applies to all low floor buses. It provides instructions for adjusting the front air bags after an alignment or for ride adjustment needs.
  • FS-2013-01 - EQUIPMENT:OTHER:OWNERS/SERVICE/OTHER MANUAL : This field service bulletin provides instructions for ordering warranty parts, filing warranty claims and returning warranty parts.
  • FS-2012-02 - STRUCTURE:BODY: Gillig: gillig's recommendations for the underbody maintenance can be found in chapter 11 of your service manual. *js
Known Recall Investigations
  • Power cable grounding investigation # PE03007

    In late october 2002, gillig corporation released a field service bulletin advising owners that a protruding bolt on the air conditioning unit (a/c) could make contact with an uninsulated power cable end and possibly cause a fire.The remedy was to remove the excess length from the a/c bolt.As a result of the agencys investigation into this matter, gillig corporation has agreed to conduct a safety recall and notify allowners of the affected vehicles. Based on the manufacturers safety recall action (03v-055), this investigation is closed.Further use of the agencys resources are unwarranted at this time.

NHTSA decoded information from VIN

138 Results returned successfully. NOTE: Any missing decoded values should be interpreted as NHTSA does not have data on the specific variable. Missing value should NOT be interpreted as an indication that a feature or technology is unavailable for a vehicle.

Variable Value
Body ClassBus
Brake System TypeAir
Bus Length40
DisplacementCC8488.499152
DisplacementCI518
DisplacementL8.488499152
Engine ManufacturerDetroit
Engine ModelDiesel Series 50
Error Text0 - VIN decoded clean. Check Digit (9th position) is correct
GVWRClass 7: 26,001 - 33,000 lb (11,794 - 14,969 kg)
GVWR_toClass 8: 33,001 lb and above (14,969 kg and above)
MakeGILLIG
MakeID554
ManufacturerGILLIG LLC
Manufacturer Id1118
ModelLow Floor Bus
ModelID2867
Model Year2003
NCSA Body TypeTransit Bus (City Bus)
NCSA MakeGillig
NCSA ModelOther (bus)
NoteGVWR: 26,000 lb and above
Plant CityHAYWARD
Plant CountryUNITED STATES (USA)
Plant StateCALIFORNIA
VIN15GGD201031073707
Vehicle TypeBUS
Most Recent Consumer Complaints and Accidents
CrashFireTowedInjuredDeathsFailure
Date
NoNoN NoneNone20030930

Ann arbor transit purchased 19 new 2003 gillig (800.735.1500) low floor 40'&35' transit buses, delivered october 2003. Immediately, ann arbor transit experienced both front exterior turn signal failures affecting all 19 new buses. The failures include burnt out bulbs, loose bulb socket metal contacts, lamp socket wiring harness falling off. Ann arbor transit has filed over forty warranty claims within the one year period only to be rejected. Ann arbor transit has spoken to gillig's service manager only to be told that we are the only customers with this problem. Gillig has supplied a new wiring harness to consider, but the new harness was rejected because it was identical to the existing. Gillig claims to be willing to help, but does nothing. Currently, all 19 buses should be considered a safety hazard due to the very unreliable front turn signal performance. Ann arbor transit operates about 90 large buses daily and is expected to provide safe, reliable, clean buses to all of our 4 million yearly customers, please help! *nm

Latest VINs Decoded for this Manufacturer
VIN Year Model Manufactured In
15GGD2015310735112003Low Floor BusHAYWARD CALIFORNIA, UNITED STATES (USA)
15GGD2713310735762003Low Floor BusHAYWARD CALIFORNIA, UNITED STATES (USA)
15GGD2010310737072003Low Floor BusHAYWARD CALIFORNIA, UNITED STATES (USA)
15GGD2017310735092003Low Floor BusHAYWARD CALIFORNIA, UNITED STATES (USA)
15GGD2719310735792003Low Floor BusHAYWARD CALIFORNIA, UNITED STATES (USA)
15GGD2011310735062003Low Floor BusHAYWARD CALIFORNIA, UNITED STATES (USA)
15GGD2017310733022003Low Floor BusHAYWARD CALIFORNIA, UNITED STATES (USA)
15GGD2715310737732003Low Floor BusHAYWARD CALIFORNIA, UNITED STATES (USA)
15GGD201X310740382003Low Floor BusHAYWARD CALIFORNIA, UNITED STATES (USA)
15GGB2014310740902003Low Floor BusHAYWARD CALIFORNIA, UNITED STATES (USA)
15GGD31XM31938952003Low Floor BusHAYWARD CALIFORNIA, UNITED STATES (USA)
15GGD2015310740612003Low Floor BusHAYWARD CALIFORNIA, UNITED STATES (USA)
15GGD2017310739802003Low Floor BusHAYWARD CALIFORNIA, UNITED STATES (USA)
15GGE2710310907702003Low Floor BusHAYWARD CALIFORNIA, UNITED STATES (USA)
15GGD2016310740362003Low Floor BusHAYWARD CALIFORNIA, UNITED STATES (USA)
15GGD2019310740632003Low Floor BusHAYWARD CALIFORNIA, UNITED STATES (USA)
15GGD2011310740392003Low Floor BusHAYWARD CALIFORNIA, UNITED STATES (USA)
15GGD2018310740542003Low Floor BusHAYWARD CALIFORNIA, UNITED STATES (USA)

© dot.report 2024

Use of this information constitutes acceptance for use in an AS IS condition. There are NO warranties, implied or otherwise, with regard to this information or its use. Any use of this information is at the user's risk. It is the responsibility of user to evaluate the accuracy, completeness or usefulness of any information, opinion, advice or other content. EACH USER WILL BE SOLELY RESPONSIBLE FOR ANY consequences of his or her direct or indirect use of this web site. ALL WARRANTIES OF ANY KIND ARE EXPRESSLY DISCLAIMED. This site will NOT BE LIABLE FOR ANY DIRECT, INDIRECT or any other kind of loss.