Gillig Low Floor 2003
Vehicle Details: Recalls, Investigations, Consumer Complaints, Decoded VIN Details, Service Bulletins
Use the box here to look up VINs from GILLIG as well as other manufacturers
Sub-models: - Low Floor Bus -
-
Where is the 2003 GILLIG Low Floor produced?
- The 2003 GILLIG Low Floor is produced in Hayward California, United States (usa).
-
Are there recalls for the 2003 GILLIG Low Floor?
- There are 9 recall(s) for the 2003 GILLIG Low Floor, additional information is below.
-
What is the GVWR of a 2003 GILLIG Low Floor?
- The 2003 GILLIG Low Floor has a GVWR of Class 7: 26,001 - 33,000 lb (11,794 - 14,969 kg) lbs.
Recall 127711 [USA]: The reduced visibility of the turn signals can increase the risk of a crash.
Recall 152782 [USA]: The reduced visibility of the turn signals may increase the risk of a crash.
Recall 67708 [USA]: A short could occur, possibly causing smoke and fire.
Recall 37038 [USA]: Failure of the line introduces high pressure fuel spray into the engine compartment which can ignite when it comes in contact with a hot surface.
Recall 61120 [USA]: Engine malfunction could possible lead to engine and vehicle damage and potential for a vehicle fire.
Recall 34540 [USA]: In the event of a vehicle crash, the wheelchair may not be adequately secured possibly resulting in injuries.
Recall 56472 [USA]: Oil leakage on a hot engine can result in an engine compartment fire, possibly resulting in injuries.
Recall 56485 [USA]: This can result in a fire in the engine compartment.
Recall 56391 [USA]: Embrittlement could potentially lead to a transducer diaphragm failure.
To ensure accuracy and for your safety, it is recommended to do a free VIN recall check here or here [USA] - UK - Canada.
Bulletins are notices put out by manufacturers in conjunction with the NHTSA to notify the public of manufacturing issues or changes.
- FS-2019-02 - ENGINE AND ENGINE COOLING:COOLING SYSTEM:HOSES/LINES/PIPING/FITTINGS: Because of a supply issue with the blue hose covering, eaton is temporarily making fc-300 hose using black covering. Fc-300 hose assemblies made between october 2018 to may 2019 will be affected by this change.
- FS-2018-02 - STEERING: A procedure to properly adjust the draglink so the socket won't over articulate, causing increased wear.
- FS-2018-01 - STEERING: It was found that an earlier bulletin spec'd bolts that could be too long due to variances in bolt shoulder length, so this bulletin was written to make sure bolt attachments were correct.
- FS-2016-06 - STEERING: Gillig has received reports of partial cracking in the steering gear mounting plate in some low floor buses. We are now requesting that owners of all low floor buses from model year 1997 through june, 2015 inspect the steering gear mounting
- FS-2016-06 - STEERING:GEAR BOX (OTHER THAN RACK AND PINION): Gillig has received reports of partial cracking in the steering gear mounting plate in some low floor buses. We are now requesting that owners of all low floor buses from model year 1997 through june, 2015 inspect the steering gear mounting
- FS-2016-05 - EQUIPMENT: This field service bulletin provides new information from borg warner (delco) revising the maintenance procedure for starter b+ cable maintenance and torque values.
- FS-2016-02 - EQUIPMENT:APPLIANCE:AIR CONDITIONER: This field service bulletin applies to all non-hybrid low floor buses with 480 volt hvac systems. It advises installation of a lockout mechanism for the battery disconnect system. Details are provided on how to obtain a lockout padlock from
- FS-2016-01 - EQUIPMENT: This field service bulletin applies to all low floor buses with skf air dryers. It warns against the use of non-skf cartridges in skf air dryers and recommends only using genuine skf cartridges.
- FS-2015-02 - EQUIPMENT:OTHER:OWNERS/SERVICE/OTHER MANUAL : This field service bulletin applies to all low floor buses. It advises on the necessity of maintaining proper ride height and provides current inspection and adjustment procedures.
- FS-2014-02 - ENGINE AND ENGINE COOLING:COOLING SYSTEM:HOSES/LINES/PIPING/FITTINGS: This field service bulletin applies to all low floor buses with aeroquip fc-300 coolant hoses. Eaton aeroquip has recently determined that newer coolants containing oat (organic acid technology) are not compatible with their fc300 hose mate
- FS-2014-01 - ELECTRICAL SYSTEM: This field service bulletin applies to all low floor buses with luminator or twin vision destination signs. It alerts owners of an operational warning issued by the supplier against utilizing the usb port on their destination sign to charge
- FS-2013-02 - AIR BAGS: This field service bulletin applies to all low floor buses. It provides instructions for adjusting the front air bags after an alignment or for ride adjustment needs.
- FS-2013-01 - EQUIPMENT:OTHER:OWNERS/SERVICE/OTHER MANUAL : This field service bulletin provides instructions for ordering warranty parts, filing warranty claims and returning warranty parts.
- FS-2012-02 - STRUCTURE:BODY: Gillig: gillig's recommendations for the underbody maintenance can be found in chapter 11 of your service manual. *js
Power cable grounding investigation # PE03007
In late october 2002, gillig corporation released a field service bulletin advising owners that a protruding bolt on the air conditioning unit (a/c) could make contact with an uninsulated power cable end and possibly cause a fire.The remedy was to remove the excess length from the a/c bolt.As a result of the agencys investigation into this matter, gillig corporation has agreed to conduct a safety recall and notify allowners of the affected vehicles. Based on the manufacturers safety recall action (03v-055), this investigation is closed.Further use of the agencys resources are unwarranted at this time.
138 Results returned successfully. NOTE: Any missing decoded values should be interpreted as NHTSA does not have data on the specific variable. Missing value should NOT be interpreted as an indication that a feature or technology is unavailable for a vehicle.
Variable | Value |
---|---|
Body Class | Bus |
Brake System Type | Air |
Bus Length | 40 |
DisplacementCC | 8488.499152 |
DisplacementCI | 518 |
DisplacementL | 8.488499152 |
Engine Manufacturer | Detroit |
Engine Model | Diesel Series 50 |
Error Text | 0 - VIN decoded clean. Check Digit (9th position) is correct |
GVWR | Class 7: 26,001 - 33,000 lb (11,794 - 14,969 kg) |
GVWR_to | Class 8: 33,001 lb and above (14,969 kg and above) |
Make | GILLIG |
MakeID | 554 |
Manufacturer | GILLIG LLC |
Manufacturer Id | 1118 |
Model | Low Floor Bus |
ModelID | 2867 |
Model Year | 2003 |
NCSA Body Type | Transit Bus (City Bus) |
NCSA Make | Gillig |
NCSA Model | Other (bus) |
Note | GVWR: 26,000 lb and above |
Plant City | HAYWARD |
Plant Country | UNITED STATES (USA) |
Plant State | CALIFORNIA |
VIN | 15GGD201031073707 |
Vehicle Type | BUS |
Crash | Fire | Towed | Injured | Deaths | Failure Date |
---|
No | No | N | None | None | 20030930 |
Ann arbor transit purchased 19 new 2003 gillig (800.735.1500) low floor 40'&35' transit buses, delivered october 2003. Immediately, ann arbor transit experienced both front exterior turn signal failures affecting all 19 new buses. The failures include burnt out bulbs, loose bulb socket metal contacts, lamp socket wiring harness falling off. Ann arbor transit has filed over forty warranty claims within the one year period only to be rejected. Ann arbor transit has spoken to gillig's service manager only to be told that we are the only customers with this problem. Gillig has supplied a new wiring harness to consider, but the new harness was rejected because it was identical to the existing. Gillig claims to be willing to help, but does nothing. Currently, all 19 buses should be considered a safety hazard due to the very unreliable front turn signal performance. Ann arbor transit operates about 90 large buses daily and is expected to provide safe, reliable, clean buses to all of our 4 million yearly customers, please help! *nm
VIN | Year | Model | Manufactured In |
---|---|---|---|
15GGD201531073511 | 2003 | Low Floor Bus | HAYWARD CALIFORNIA, UNITED STATES (USA) |
15GGD271331073576 | 2003 | Low Floor Bus | HAYWARD CALIFORNIA, UNITED STATES (USA) |
15GGD201031073707 | 2003 | Low Floor Bus | HAYWARD CALIFORNIA, UNITED STATES (USA) |
15GGD201731073509 | 2003 | Low Floor Bus | HAYWARD CALIFORNIA, UNITED STATES (USA) |
15GGD271931073579 | 2003 | Low Floor Bus | HAYWARD CALIFORNIA, UNITED STATES (USA) |
15GGD201131073506 | 2003 | Low Floor Bus | HAYWARD CALIFORNIA, UNITED STATES (USA) |
15GGD201731073302 | 2003 | Low Floor Bus | HAYWARD CALIFORNIA, UNITED STATES (USA) |
15GGD271531073773 | 2003 | Low Floor Bus | HAYWARD CALIFORNIA, UNITED STATES (USA) |
15GGD201X31074038 | 2003 | Low Floor Bus | HAYWARD CALIFORNIA, UNITED STATES (USA) |
15GGB201431074090 | 2003 | Low Floor Bus | HAYWARD CALIFORNIA, UNITED STATES (USA) |
15GGD31XM3193895 | 2003 | Low Floor Bus | HAYWARD CALIFORNIA, UNITED STATES (USA) |
15GGD201531074061 | 2003 | Low Floor Bus | HAYWARD CALIFORNIA, UNITED STATES (USA) |
15GGD201731073980 | 2003 | Low Floor Bus | HAYWARD CALIFORNIA, UNITED STATES (USA) |
15GGE271031090770 | 2003 | Low Floor Bus | HAYWARD CALIFORNIA, UNITED STATES (USA) |
15GGD201631074036 | 2003 | Low Floor Bus | HAYWARD CALIFORNIA, UNITED STATES (USA) |
15GGD201931074063 | 2003 | Low Floor Bus | HAYWARD CALIFORNIA, UNITED STATES (USA) |
15GGD201131074039 | 2003 | Low Floor Bus | HAYWARD CALIFORNIA, UNITED STATES (USA) |
15GGD201831074054 | 2003 | Low Floor Bus | HAYWARD CALIFORNIA, UNITED STATES (USA) |