Gillig Low Floor 2010

Vehicle Details: Recalls, Decoded VIN Details, Service Bulletins

Below you will find all available information on the 2010 GILLIG Low Floor, manufacturered by Gillig Llc.
The vehicle is described as a Transit Bus (City Bus).

ManufacturerKnown WMI(s)Fuel Type
GILLIG15G 46G
GILLIG VIN Decoder

Use the box here to look up VINs from GILLIG as well as other manufacturers

#

Sub-models: - Low Floor Bus -

Frequently Asked Questions
  • Where is the 2010 GILLIG Low Floor produced?
     - The 2010 GILLIG Low Floor is produced in Hayward California, United States (usa).
  • Are there recalls for the 2010 GILLIG Low Floor?
     - There are 9 recall(s) for the 2010 GILLIG Low Floor, additional information is below.
  • What is the GVWR of a 2010 GILLIG Low Floor?
     - The 2010 GILLIG Low Floor has a GVWR of Class 7: 26,001 - 33,000 lb (11,794 - 14,969 kg) lbs.
NHTSA Mandated Recalls
  • Recall 127723 [USA]: The reduced visibility of the turn signals can increase the risk of a crash.

  • Recall 152788 [USA]: The reduced visibility of the turn signals may increase the risk of a crash.

  • Recall 119754 [USA]: If the seatbelt anchorage assembly separates from the j-bracket, the bus driver may not be properly restrained in the event of a crash increasing their risk of injury.

  • Recall 108429 [USA]: If the electrical power cable rubs against the injector fuel line, the cable may short circuit or the fuel line may leak fuel. either possibility increases the risk of a fire.

  • Recall 115716 [USA]: If engine oil comes into contact with a hot surface, there is an increased risk of a fire.

  • Recall 104618 [USA]: If the sampling hose leaks oil in the presence of hot engine engine exhaust components, there is an increased risk of fire.

  • Recall 101660 [USA]: The improper operation of the sensor could induce elevated exhaust temperatures or flames from the exhaust pipe, increasing the risk of a vehicle fire.

  • Recall 93408 [USA]: In the event the egress window handle fails during an actual emergency situation, passengers may be trapped in the vehicle placing them at risk of injury.

  • Recall 77199 [USA]: If the inlet or outlet sections disconnect, hot exhaust gases can vent prior to exiting the tailpipe, creating the risk of combustion and a fire. if both clamps fail, there is a risk in some applications that the doc/dpf housing may detach completely, creating a road hazard.

To ensure accuracy and for your safety, it is recommended to do a free VIN recall check here or here [USA] - UK - Canada.

Bulletins

Bulletins are notices put out by manufacturers in conjunction with the NHTSA to notify the public of manufacturing issues or changes.

  • FS-2019-02 - ENGINE AND ENGINE COOLING:COOLING SYSTEM:HOSES/LINES/PIPING/FITTINGS: Because of a supply issue with the blue hose covering, eaton is temporarily making fc-300 hose using black covering. Fc-300 hose assemblies made between october 2018 to may 2019 will be affected by this change.
  • FS-2018-02 - STEERING: A procedure to properly adjust the draglink so the socket won't over articulate, causing increased wear.
  • FS-2018-01 - STEERING: It was found that an earlier bulletin spec'd bolts that could be too long due to variances in bolt shoulder length, so this bulletin was written to make sure bolt attachments were correct.
  • FS-2016-06 - STEERING: Gillig has received reports of partial cracking in the steering gear mounting plate in some low floor buses. We are now requesting that owners of all low floor buses from model year 1997 through june, 2015 inspect the steering gear mounting
  • FS-2017-04 - FUEL SYSTEM, OTHER:DELIVERY:HOSES, LINES/PIPING, AND FITTINGS: This field service bulletin is informing vehicle owners and aftermarket part purchasers that the pressure relief device (prd) vent tube caps on agility cng systems are important to maintain to help prevent moisture and/or debris from causin
  • FS-2017-03 - SUSPENSION: This field service bulletin is informing vehicle owners and aftermarket part purchasers that neway?, a saf-holland? Division, has identified some suspension installation and monitoring issues on the adlsd-120 suspension used on 29' gillig b
  • FS-2016-06 - STEERING:GEAR BOX (OTHER THAN RACK AND PINION): Gillig has received reports of partial cracking in the steering gear mounting plate in some low floor buses. We are now requesting that owners of all low floor buses from model year 1997 through june, 2015 inspect the steering gear mounting
  • FS-2016-05 - EQUIPMENT: This field service bulletin provides new information from borg warner (delco) revising the maintenance procedure for starter b+ cable maintenance and torque values.
  • FS-2016-02 - EQUIPMENT:APPLIANCE:AIR CONDITIONER: This field service bulletin applies to all non-hybrid low floor buses with 480 volt hvac systems. It advises installation of a lockout mechanism for the battery disconnect system. Details are provided on how to obtain a lockout padlock from
  • FS-2016-01 - EQUIPMENT: This field service bulletin applies to all low floor buses with skf air dryers. It warns against the use of non-skf cartridges in skf air dryers and recommends only using genuine skf cartridges.
  • FS-2015-02 - EQUIPMENT:OTHER:OWNERS/SERVICE/OTHER MANUAL : This field service bulletin applies to all low floor buses. It advises on the necessity of maintaining proper ride height and provides current inspection and adjustment procedures.
  • FS-2014-02 - ENGINE AND ENGINE COOLING:COOLING SYSTEM:HOSES/LINES/PIPING/FITTINGS: This field service bulletin applies to all low floor buses with aeroquip fc-300 coolant hoses. Eaton aeroquip has recently determined that newer coolants containing oat (organic acid technology) are not compatible with their fc300 hose mate
  • FS-2014-01 - ELECTRICAL SYSTEM: This field service bulletin applies to all low floor buses with luminator or twin vision destination signs. It alerts owners of an operational warning issued by the supplier against utilizing the usb port on their destination sign to charge
  • FS-2013-03 - ENGINE AND ENGINE COOLING:EXHAUST SYSTEM: This field service bulletin applies to all low floor buses with a cummins isl engine. It advises replacement of the exhaust system flex pipe. Details are provided regarding the upcoming delivery of a replacement part, alignment tool, print,
  • FS-2013-02 - AIR BAGS: This field service bulletin applies to all low floor buses. It provides instructions for adjusting the front air bags after an alignment or for ride adjustment needs.
  • FS-2013-01 - EQUIPMENT:OTHER:OWNERS/SERVICE/OTHER MANUAL : This field service bulletin provides instructions for ordering warranty parts, filing warranty claims and returning warranty parts.
  • FS-2012-06 - ENGINE AND ENGINE COOLING:EXHAUST SYSTEM:EMISSION CONTROL: This field service bulletin applies to all low floor buses with 2010 emissions compliant engines. It informs of owners of a technical service bulletin from the supplier of the diesel exhaust fluid (def) tank used on gillig buses. Approximat
  • FS-2012-05 - ENGINE AND ENGINE COOLING:EXHAUST SYSTEM: This field service bulletin applies to all hybrid and 35-ft/40-ft standard low floor buses with cummins isl engines. It advises replacement of the exhaust system flex pipe. Details are provided regarding the upcoming delivery of a replaceme
  • FS-2012-03 - ENGINE AND ENGINE COOLING:EXHAUST SYSTEM: This field service bulletin applies to all cng powered low floor buses. It advises replacement of the exhaust system flex pipe. Details are provided regarding the upcoming delivery of a replacement part, alignment tool, print, and replaceme
  • FS-2012-02 - STRUCTURE:BODY: Gillig: gillig's recommendations for the underbody maintenance can be found in chapter 11 of your service manual. *js
NHTSA decoded information from VIN

138 Results returned successfully. NOTE: Any missing decoded values should be interpreted as NHTSA does not have data on the specific variable. Missing value should NOT be interpreted as an indication that a feature or technology is unavailable for a vehicle.

Variable Value
Body ClassBus
Brake System TypeAir
Bus Length40
DisplacementCC8900.0
DisplacementCI540
DisplacementL8.9
Engine ManufacturerCummins
Engine ModelDiesel ISL
Error Text0 - VIN decoded clean. Check Digit (9th position) is correct
GVWRClass 7: 26,001 - 33,000 lb (11,794 - 14,969 kg)
GVWR_toClass 8: 33,001 lb and above (14,969 kg and above)
MakeGILLIG
MakeID554
ManufacturerGILLIG LLC
Manufacturer Id1118
ModelLow Floor Bus
ModelID2867
Model Year2010
NCSA Body TypeTransit Bus (City Bus)
NCSA MakeGillig
NCSA ModelOther (bus)
NoteGVWR: 26,000 lb and above
Plant CityHAYWARD
Plant CountryUNITED STATES (USA)
Plant StateCALIFORNIA
VIN15GGD2711A1179263
Vehicle TypeBUS
Vehicle Documentation
[pdf]
Fayettville Area System of Transit Review Lift Reliability and Maintenance for Operation Fixed Route Bus Service Commitment to Accessibility DOT is committed ensuring that information available in appropriate alternative formats meet the requirements persons who have a disability If you require an version this file please contact FTAWebAccessibility@dot gov Federal Administration USDOT Fayetteville FAST NC March 22 25 2010 Lifts Final Report transit dot sites fta files docs
Fayetteville Area System of Transit FAST Fayetteville, NC Review of Lift Reliability and Maintenance for Operation of Fixed Route Bus Service March 22-25, 2010 Summary of Observations Prepared for Federal Transit Administration Office of Civil Rights Washington, DC Prepared by Planners ...
lang:en score:14 filesize: 3.26 M page_count: 95 document date: 2016-02-25
Latest VINs Decoded for this Manufacturer
VIN Year Model Manufactured In
15GGD2719A11792672010Low Floor BusHAYWARD CALIFORNIA, UNITED STATES (USA)
15GGD2711A11792632010Low Floor BusHAYWARD CALIFORNIA, UNITED STATES (USA)
15GGD3016A11773152010Low Floor BusHAYWARD CALIFORNIA, UNITED STATES (USA)
15GGD3017A11773102010Low Floor BusHAYWARD CALIFORNIA, UNITED STATES (USA)
15GGD3014A11773142010Low Floor BusHAYWARD CALIFORNIA, UNITED STATES (USA)
15GGD2718A11771402010Low Floor BusHAYWARD CALIFORNIA, UNITED STATES (USA)
15GGB2718A11770322010Low Floor BusHAYWARD CALIFORNIA, UNITED STATES (USA)
15GGD3019A10791202010Low Floor BusHAYWARD CALIFORNIA, UNITED STATES (USA)
15GGD2714A11789022010Low Floor BusHAYWARD CALIFORNIA, UNITED STATES (USA)
15GGD271XA11771412010Low Floor BusHAYWARD CALIFORNIA, UNITED STATES (USA)
15GGB2711A11770482010Low Floor BusHAYWARD CALIFORNIA, UNITED STATES (USA)
15GGD2714A11771492010Low Floor BusHAYWARD CALIFORNIA, UNITED STATES (USA)
15GGD2710A11771472010Low Floor BusHAYWARD CALIFORNIA, UNITED STATES (USA)
15GGB271XA11770472010Low Floor BusHAYWARD CALIFORNIA, UNITED STATES (USA)
15GGD2717A11771312010Low Floor BusHAYWARD CALIFORNIA, UNITED STATES (USA)
15GGB2713A11770492010Low Floor BusHAYWARD CALIFORNIA, UNITED STATES (USA)
15GGD2717A11771592010Low Floor BusHAYWARD CALIFORNIA, UNITED STATES (USA)
15GGB2712A11770572010Low Floor BusHAYWARD CALIFORNIA, UNITED STATES (USA)
15GGD2715A11771442010Low Floor BusHAYWARD CALIFORNIA, UNITED STATES (USA)
15GGD2712A11771512010Low Floor BusHAYWARD CALIFORNIA, UNITED STATES (USA)
15GGD2717A11771622010Low Floor BusHAYWARD CALIFORNIA, UNITED STATES (USA)
15GGD2712A11771482010Low Floor BusHAYWARD CALIFORNIA, UNITED STATES (USA)
15GGB271XA11770502010Low Floor BusHAYWARD CALIFORNIA, UNITED STATES (USA)
15GGB2711A11770512010Low Floor BusHAYWARD CALIFORNIA, UNITED STATES (USA)

© dot.report 2024

Use of this information constitutes acceptance for use in an AS IS condition. There are NO warranties, implied or otherwise, with regard to this information or its use. Any use of this information is at the user's risk. It is the responsibility of user to evaluate the accuracy, completeness or usefulness of any information, opinion, advice or other content. EACH USER WILL BE SOLELY RESPONSIBLE FOR ANY consequences of his or her direct or indirect use of this web site. ALL WARRANTIES OF ANY KIND ARE EXPRESSLY DISCLAIMED. This site will NOT BE LIABLE FOR ANY DIRECT, INDIRECT or any other kind of loss.