2055693/2

Service Bulletin Details

Public Details for: 2055693/2

Unable to run basic settings within the adaptive suspension control unit (j775). Customer statement/workshop findings: unable to run basic setting (full process + rebound end stops) after a new adaptive air suspension control unit has bee


- 2021 - 2020 - 2019 - 2018 - 2017 -

Technical product information
Topic
Market area
Brand
Transaction No.
Level
Status
Release date
Unable to run basic settings within the Adaptive suspension control unit (J775)
Bentley: worldwide (2WBE),Hongkong-Macau (5HK)
Bentley
2055693/2
EH
Released for publishing
03-Jul-2020
Event memory entries
Diagnostic address
Event memory entry
0074 - Chassis control
0074 - Chassis control
0074 - Chassis control
0074 - Chassis control
0074 - Chassis control
0074 - Chassis control
0074 - Chassis control
0074 - Chassis control
C1034F0: Left front level control system sensor Rebound stop detected
C1034F0: Left front level control system sensor Rebound stop detected
C1035F0: Right front level control sensor Rebound stop detected
C1035F0: Right front level control sensor Rebound stop detected
C10CD29: Level control system sensor Range/Performance
C10CD29: Level control system sensor Range/Performance
C1036F0: Left rear level control system sensor Rebound stop detected
C1036F0: Left rear level control system sensor Rebound stop detected
Fault type Fault status
Intermittent
static
Intermittent
static
Intermittent
static
Intermittent
static
New customer code
Object of complaint
Complaint type
vehicle service -> vehicle diagnosis -> guided fault finding
control units, services -> with event log
entry
running gear -> shock absorber/suspension control -> self-levelling suspension
adjustment
running gear -> adaptive suspension, pitch and roll compensation
running gear -> adaptive suspension, pitch and roll compensation
functionality -> without function / defect
Vehicle data
Bentayga series
Sales types
Type MY Brand Designation Engine code Gearbox code Final drive code
4V1*
4V1*
4V1*
4V1*
4V1*
2017
2018
2019
2020
2021
E
E
E
E
E
Documents
Document name
master.xml
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
functionality
dimensional accuracy
Position
Technical product information
Unable to run basic settings within the Adaptive suspension control unit (J775)
Transaction No.: 2055693/2
Release date: 03-Jul-2020
Customer statement / workshop findings
Unable to run Basic setting (full process + rebound end stops) after a new adaptive air suspension control unit has been fitted or work has been
conducted on the suspension system which requires the Basic setting (full process + rebound end stops) procedure performing
Technical background
Referring to Figure 1, During the Basic setting (full process + rebound end stops) the routine can stop during the initial part of the procedure, in
particular at the stage shown in Figure 2, which is when the vehicle is raised to allow all four wheels to hang down to their full rebound position
Should this issue be evident and the Basic settings routine does not continue - Refer to the Measure section of this TPI
Figure 1
Figure 2
Production change
-
Measure
1) Navigate to address 74
- Select Guided functions
- Select Read measured values (Figure 3)
Figure 3
2) When prompted search for IDE 07151 –
- When IDE 07151 is located - Select - Starting update
- Monitor the measured value results for each level control sensor (Figure 4)
Figure 4
- Compare the sensor measured results in Figure 4 against the correct tolerance bands shown in Figure 5
- Within the example shown, the left hand rear level control sensor is not in tolerance as the value is 72.06%
Figure 5
3) To allow the Basic setting (full process + rebound end stops) to be successfully completed the measured value results must all be within the
tolerance bands shown in Figure 5
•
Manually adjust the out of range level sensor by moving the sensor connecting arm whilst monitoring the values until the value falls within
the specified tolerance band
Referring to Figure 6, The correct tolerance should be achieved by moving the sensor arm ( by hand within the parts natural limits of
movement) in the required direction until the tolerance band is within specification NOTE: The tolerance can be achieved by using the
recommended method
NOTE: For photographic purposes only the left hand rear sensor is shown in Figure 6
Figure 6
DO NOT ATTEMPT TO ADJUST THE TOLERANCE BAND OF THE LEVEL SENSORS BY PRYING,BENDING OR
MANIPULATING THE SENSOR RODS BY THE USE OF FORCE
•
Once the required tolerance band criteria is met carry out the Basic setting (full process + rebound end stops) until completion


© dot.report 2024

Use of this information constitutes acceptance for use in an AS IS condition. There are NO warranties, implied or otherwise, with regard to this information or its use. Any use of this information is at the user's risk. It is the responsibility of user to evaluate the accuracy, completeness or usefulness of any information, opinion, advice or other content. EACH USER WILL BE SOLELY RESPONSIBLE FOR ANY consequences of his or her direct or indirect use of this web site. ALL WARRANTIES OF ANY KIND ARE EXPRESSLY DISCLAIMED. This site will NOT BE LIABLE FOR ANY DIRECT, INDIRECT or any other kind of loss.