SSM 46371

Service Bulletin Details

Public Details for: SSM 46371

Some 2012-2017 focus electric/2013-2017 cmax energi/fusion energi/2015-2017 mkc/mkz/2016-2017 mkx and 2017 continental vehicles operating with a 3g tcu on or before 16-jan-2017 may not respond to customers remote commands via mylincoln/myfo


- 2017 - 2016 - 2015 - 2014 - 2013 - 2012 -

SSM
46371
Some 2012-2017 Focus Electric/2013-2017 CMAX Energi/Fusion Energi/2015-2017
MKC/MKZ/2016-2017 MKX and 2017 Continental vehicles operating with a 3G TCU on or before 16Jan-2017 may not respond to customers remote commands via MyLincoln/MyFord Mobile phone
applications. 2G networks were decommissioned on 16-Jan-2017. If the 3G TCU was operating on
a 2G network, it will not automatically attempt to reconnect to the replacement 3G network. To
correct, reset the TCU by removing its power fuse for 5 minutes. If the concern is still present, follow
normal diagnostics in Workshop Manual (WSM), Section 415-00. Refer to PTS OASIS home page
for TCU version identification. For claiming, use causal part 14G229 and applicable labor operations
in section 10 of the service labor time standards (SLTS) manual.


© dot.report 2024

Use of this information constitutes acceptance for use in an AS IS condition. There are NO warranties, implied or otherwise, with regard to this information or its use. Any use of this information is at the user's risk. It is the responsibility of user to evaluate the accuracy, completeness or usefulness of any information, opinion, advice or other content. EACH USER WILL BE SOLELY RESPONSIBLE FOR ANY consequences of his or her direct or indirect use of this web site. ALL WARRANTIES OF ANY KIND ARE EXPRESSLY DISCLAIMED. This site will NOT BE LIABLE FOR ANY DIRECT, INDIRECT or any other kind of loss.